BD3030 CUTLER-HAMMER CIRCUIT PROTECT DEV STANDARD TRIP PLUG-IN CIRCUIT BREAKERS
THERMAL MAGNETIC; DUPLEX; INDEPENDENT TRIP; 3 POLE; 120 VAC; 30 AMPERE (OUTSIDE POLE; INSIDE POLE); INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BD MODEL
$16.24 -
BD3020 CUTLER-HAMMER CIRCUIT PROTECT DEV STANDARD TRIP PLUG-IN CIRCUIT BREAKERS
THERMAL MAGNETIC; DUPLEX; INDEPENDENT TRIP; 3 POLE; 120 VAC; 30 AMPERE (OUTSIDE POLE); 20 AMPERE (INSIDE POLE); INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BD MODEL
$12.21 -
BD2030 CUTLER-HAMMER CIRCUIT PROTECT DEV STANDARD TRIP PLUG-IN CIRCUIT BREAKERS
THERMAL MAGNETIC; DUPLEX; INDEPENDENT TRIP; 2 POLE; 120 VAC; 20 AMPERE (OUTSIDE POLE); 30 AMPERE (INSIDE POLE); INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BD MODEL
$16.24 -
BD2020 CUTLER-HAMMER CIRCUIT PROTECT DEV STANDARD TRIP PLUG-IN CIRCUIT BREAKERS
THERMAL MAGNETIC; DUPLEX; INDEPENDENT TRIP; 2 POLE; 120 VAC; 20 AMPERE (OUTSIDE POLE; INSIDE POLE); INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BD MODEL
$16.24 -
BD2015 CUTLER-HAMMER CIRCUIT PROTECT DEV STANDARD TRIP PLUG-IN CIRCUIT BREAKERS
THERMAL MAGNETIC; DUPLEX; INDEPENDENT TRIP; 2 POLE; 120 VAC; 20 AMPERE (OUTSIDE POLE); 15 AMPERE (INSIDE POLE); INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BD MODEL
$16.24 -
BD1520 CUTLER-HAMMER CIRCUIT PROTECT DEV STANDARD TRIP PLUG-IN CIRCUIT BREAKERS
THERMAL MAGNETIC; DUPLEX; INDEPENDENT TRIP; 1 POLE; 120 VAC; 15 AMPERE (OUTSIDE POLE); 20 AMPERE (INSIDE POLE); INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BD MODEL
$16.24 -
BD1515 CUTLER-HAMMER CIRCUIT PROTECT DEV STANDARD TRIP PLUG-IN CIRCUIT BREAKERS
THERMAL MAGNETIC; DUPLEX; INDEPENDENT TRIP; 1 POLE; 120 VAC; 15 AMPERE (OUTSIDE POLE; INSIDE POLE); INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BD MODEL
$16.24 -
BAB3100H CUTLER-HAMMER MULTIPLE METERING STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 3 POLE; 240 VAC; 100 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; EXTENDED TANG LINE TERMINAL; BOX LUG LOAD TERMINAL TERMINAL; WIRE SIZE 8 TO 1/0 AWG (ALUMINUM/COPPER; LOAD); BOLT ON MOUNTING; APPROVAL UL 489; CSA
$192.13 -
BAB3090H CUTLER-HAMMER MULTIPLE METERING STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 3 POLE; 240 VAC; 90 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; EXTENDED TANG LINE TERMINAL; BOX LUG LOAD TERMINAL TERMINAL; WIRE SIZE 8 TO 1/0 AWG (ALUMINUM/COPPER; LOAD); BOLT ON MOUNTING; APPROVAL UL 489; CSA
$218.28 -
BAB3080H CUTLER-HAMMER MULTIPLE METERING STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 3 POLE; 240 VAC; 80 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; EXTENDED TANG LINE TERMINAL; BOX LUG LOAD TERMINAL TERMINAL; WIRE SIZE 8 TO 1/0 AWG (ALUMINUM/COPPER; LOAD); BOLT ON MOUNTING; APPROVAL UL 489; CSA
$192.13 -
BAB3060HS CUTLER-HAMMER MULTIPLE METERING STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 3 POLE; 240 VAC; 60 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; EXTENDED TANG LINE TERMINAL; BOX LUG LOAD TERMINAL TERMINAL; WIRE SIZE 8 TO 1/0 AWG (ALUMINUM/COPPER; LOAD); BOLT ON MOUNTING; APPROVAL UL 489; CSA
$280.48 -
BAB3060H CUTLER-HAMMER MULTIPLE METERING STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 3 POLE; 240 VAC; 60 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; EXTENDED TANG LINE TERMINAL; BOX LUG LOAD TERMINAL TERMINAL; WIRE SIZE 8 TO 1/0 AWG (ALUMINUM/COPPER; LOAD); BOLT ON MOUNTING; APPROVAL UL 489; CSA
$128.09 -
BAB3050HS CUTLER-HAMMER MULTIPLE METERING STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 3 POLE; 240 VAC; 50 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; EXTENDED TANG LINE TERMINAL; BOX LUG LOAD TERMINAL TERMINAL; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER; LOAD); BOLT ON MOUNTING; APPROVAL UL 489; CSA
$280.48 -
BAB3050H CUTLER-HAMMER MULTIPLE METERING STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 3 POLE; 240 VAC; 50 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; EXTENDED TANG LINE TERMINAL; BOX LUG LOAD TERMINAL TERMINAL; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER; LOAD); BOLT ON MOUNTING; APPROVAL UL 489; CSA
$130.67 -
BAB3040HS CUTLER-HAMMER MULTIPLE METERING STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 3 POLE; 240 VAC; 40 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; EXTENDED TANG LINE TERMINAL; BOX LUG LOAD TERMINAL TERMINAL; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER; LOAD); BOLT ON MOUNTING; APPROVAL UL 489; CSA
$280.48 -
BAB3040H CUTLER-HAMMER MULTIPLE METERING STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 3 POLE; 240 VAC; 40 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; EXTENDED TANG LINE TERMINAL; BOX LUG LOAD TERMINAL TERMINAL; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER; LOAD); BOLT ON MOUNTING; APPROVAL UL 489; CSA
$130.67 -
BAB3030HS CUTLER-HAMMER MULTIPLE METERING STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 3 POLE; 240 VAC; 30 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; EXTENDED TANG LINE TERMINAL TERMINAL; BOLT ON MOUNTING; APPROVAL UL 489; CSA; QUICKLAG[R] BRAND; BAB MODEL; WITH 120/208/240 VAC SHUNT TRIP
$280.48 -
BAB3030H CUTLER-HAMMER MULTIPLE METERING STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 3 POLE; 240 VAC; 30 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; EXTENDED TANG LINE TERMINAL TERMINAL; BOLT ON MOUNTING; APPROVAL UL 489; CSA; QUICKLAG[R] BRAND; BAB MODEL
$130.67 -
BAB3025H CUTLER-HAMMER MULTIPLE METERING STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 3 POLE; 240 VAC; 25 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; EXTENDED TANG LINE TERMINAL TERMINAL; BOLT ON MOUNTING; APPROVAL UL 489; CSA; QUICKLAG[R] BRAND; BAB MODEL
$145.65 -
BAB3020HS CUTLER-HAMMER MULTIPLE METERING STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 3 POLE; 240 VAC; 20 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; EXTENDED TANG LINE TERMINAL TERMINAL; BOLT ON MOUNTING; APPROVAL UL 489; CSA; QUICKLAG[R] BRAND; BAB MODEL; WITH 120/208/240 VAC SHUNT TRIP
$280.48 -
BAB3020H CUTLER-HAMMER MULTIPLE METERING STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 3 POLE; 240 VAC; 20 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; EXTENDED TANG LINE TERMINAL TERMINAL; BOLT ON MOUNTING; APPROVAL UL 489; CSA; QUICKLAG[R] BRAND; BAB MODEL
$130.67 -
BAB3015H CUTLER-HAMMER MULTIPLE METERING STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 3 POLE; 240 VAC; 15 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; EXTENDED TANG LINE TERMINAL TERMINAL; BOLT ON MOUNTING; APPROVAL UL 489; CSA; QUICKLAG[R] BRAND; BAB MODEL
$130.67 -
BAB2125 CUTLER-HAMMER MULTIPLE METERING STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 125 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 5000 AMPERE AT 24 TO 48/62.5/80 VDC; EXTENDED TANG LINE TERMINAL; BOX LUG LOAD TERMINAL TERMINAL
$255.30 -
BAB2100S CUTLER-HAMMER MULTIPLE METERING STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 100 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 5000 AMPERE AT 24 TO 48/62.5/80 VDC; EXTENDED TANG LINE TERMINAL; BOX LUG LOAD TERMINAL TERMINAL
$249.57 -
BAB2100 CUTLER-HAMMER MULTIPLE METERING STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 100 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 5000 AMPERE AT 24 TO 48/62.5/80 VDC; EXTENDED TANG LINE TERMINAL; BOX LUG LOAD TERMINAL TERMINAL
$107.72