-
BAB2090 CUTLER-HAMMER MULTIPLE METERING STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 90 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 5000 AMPERE AT 24 TO 48/62.5/80 VDC; EXTENDED TANG LINE TERMINAL; BOX LUG LOAD TERMINAL TERMINAL; WIRE SIZE 8 TO 1/0 AWG (ALUMINUM/COPPER; LOAD)
$107.72 -
BAB2080 CUTLER-HAMMER MULTIPLE METERING STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 80 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 5000 AMPERE AT 24 TO 48/62.5/80 VDC; EXTENDED TANG LINE TERMINAL; BOX LUG LOAD TERMINAL TERMINAL; WIRE SIZE 8 TO 1/0 AWG (ALUMINUM/COPPER; LOAD)
$107.72 -
BAB2070 CUTLER-HAMMER MULTIPLE METERING STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 70 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 5000 AMPERE AT 24 TO 48/62.5/80 VDC; EXTENDED TANG LINE TERMINAL; BOX LUG LOAD TERMINAL TERMINAL; WIRE SIZE 8 TO 1/0 AWG (ALUMINUM/COPPER; LOAD)
$79.76 -
BAB2060S CUTLER-HAMMER MULTIPLE METERING STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 60 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 5000 AMPERE AT 24 TO 48/62.5/80 VDC; EXTENDED TANG LINE TERMINAL; BOX LUG LOAD TERMINAL TERMINAL; WIRE SIZE 8 TO 1/0 AWG (ALUMINUM/COPPER; LOAD)
$169.05 -
BAB2060 CUTLER-HAMMER MULTIPLE METERING STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 60 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 5000 AMPERE AT 24 TO 48/62.5/80 VDC; EXTENDED TANG LINE TERMINAL; BOX LUG LOAD TERMINAL TERMINAL; WIRE SIZE 8 TO 1/0 AWG (ALUMINUM/COPPER; LOAD)
$42.86 -
BAB2050S CUTLER-HAMMER MULTIPLE METERING STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 50 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 5000 AMPERE AT 24 TO 48/62.5/80 VDC; EXTENDED TANG LINE TERMINAL TERMINAL; BOLT ON MOUNTING; APPROVAL UL 489; CSA; QUICKLAG[R] BRAND; BAB MODEL
$169.05 -
BAB2050 CUTLER-HAMMER MULTIPLE METERING STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 50 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 5000 AMPERE AT 24 TO 48/62.5/80 VDC; EXTENDED TANG LINE TERMINAL TERMINAL; BOLT ON MOUNTING; APPROVAL UL 489; CSA; QUICKLAG[R] BRAND; BAB MODEL
$62.51 -
BAB2045 CUTLER-HAMMER MULTIPLE METERING STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 45 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 5000 AMPERE AT 24 TO 48/62.5/80 VDC; EXTENDED TANG LINE TERMINAL TERMINAL; BOLT ON MOUNTING; APPROVAL UL 489; CSA; QUICKLAG[R] BRAND; BAB MODEL
$62.51 -
BAB2040S CUTLER-HAMMER MULTIPLE METERING STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 40 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 5000 AMPERE AT 24 TO 48/62.5/80 VDC; EXTENDED TANG LINE TERMINAL TERMINAL; BOLT ON MOUNTING; APPROVAL UL 489; CSA; QUICKLAG[R] BRAND; BAB MODEL
$169.05 -
BAB2040 CUTLER-HAMMER MULTIPLE METERING STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 40 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 5000 AMPERE AT 24 TO 48/62.5/80 VDC; EXTENDED TANG LINE TERMINAL TERMINAL; BOLT ON MOUNTING; APPROVAL UL 489; CSA; QUICKLAG[R] BRAND; BAB MODEL
$62.51 -
BAB2035 CUTLER-HAMMER MULTIPLE METERING STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 35 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 5000 AMPERE AT 24 TO 48/62.5/80 VDC; EXTENDED TANG LINE TERMINAL TERMINAL; BOLT ON MOUNTING; APPROVAL UL 489; CSA; QUICKLAG[R] BRAND; BAB MODEL
$62.51 -
BAB2030S CUTLER-HAMMER MULTIPLE METERING STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 30 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 5000 AMPERE AT 24 TO 48/62.5/80 VDC; EXTENDED TANG LINE TERMINAL; BOX LUG LOAD TERMINAL TERMINAL; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER; LOAD)
$169.05 -
BAB2030 CUTLER-HAMMER MULTIPLE METERING STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 30 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 5000 AMPERE AT 24 TO 48/62.5/80 VDC; EXTENDED TANG LINE TERMINAL; BOX LUG LOAD TERMINAL TERMINAL; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER; LOAD)
$71.03 -
BAB2025 CUTLER-HAMMER MULTIPLE METERING STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 25 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 5000 AMPERE AT 24 TO 48/62.5/80 VDC; EXTENDED TANG LINE TERMINAL; BOX LUG LOAD TERMINAL TERMINAL; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER; LOAD)
$62.51 -
BAB2020S CUTLER-HAMMER MULTIPLE METERING STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 20 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 5000 AMPERE AT 24 TO 48/62.5/80 VDC; EXTENDED TANG LINE TERMINAL; BOX LUG LOAD TERMINAL TERMINAL; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER; LOAD)
$169.05 -
BAB2020 CUTLER-HAMMER MULTIPLE METERING STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 20 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 5000 AMPERE AT 24 TO 48/62.5/80 VDC; EXTENDED TANG LINE TERMINAL; BOX LUG LOAD TERMINAL TERMINAL; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER; LOAD)
$62.51 -
BAB2015 CUTLER-HAMMER MULTIPLE METERING STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 15 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 5000 AMPERE AT 24 TO 48/62.5/80 VDC; EXTENDED TANG LINE TERMINAL; BOX LUG LOAD TERMINAL TERMINAL; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER; LOAD)
$62.51 -
BAB1060 CUTLER-HAMMER MULTIPLE METERING STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120/240 VAC; 60 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 5000 AMPERE AT 24 TO 48 VDC; 2500 AMPERE AT 62.5 VDC; EXTENDED TANG LINE TERMINAL; BOX LUG LOAD TERMINAL TERMINAL
$19.11 -
BAB1055 CUTLER-HAMMER MULTIPLE METERING STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120/240 VAC; 55 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 5000 AMPERE AT 24 TO 48 VDC; 2500 AMPERE AT 62.5 VDC; EXTENDED TANG LINE TERMINAL; BOX LUG LOAD TERMINAL TERMINAL
$27.86 -
BAB1050 CUTLER-HAMMER MULTIPLE METERING STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120/240 VAC; 50 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 5000 AMPERE AT 24 TO 48 VDC; 3800 AMPERE AT 62.5 VDC; EXTENDED TANG LINE TERMINAL TERMINAL; BOLT ON MOUNTING; APPROVAL UL 489; CSA
$19.11 -
BAB1040 CUTLER-HAMMER MULTIPLE METERING STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120/240 VAC; 40 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 5000 AMPERE AT 24 TO 48 VDC; 3800 AMPERE AT 62.5 VDC; EXTENDED TANG LINE TERMINAL TERMINAL; BOLT ON MOUNTING; APPROVAL UL 489; CSA
$19.11 -
BAB1030S CUTLER-HAMMER MULTIPLE METERING STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120/240 VAC; 30 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 5000 AMPERE AT 24 TO 48 VDC; 3800 AMPERE AT 62.5 VDC; EXTENDED TANG LINE TERMINAL; BOX LUG LOAD TERMINAL TERMINAL
$142.34 -
BAB1030 CUTLER-HAMMER MULTIPLE METERING STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120/240 VAC; 30 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 5000 AMPERE AT 24 TO 48 VDC; 3800 AMPERE AT 62.5 VDC; EXTENDED TANG LINE TERMINAL; BOX LUG LOAD TERMINAL TERMINAL
$18.46 -
BAB1025 CUTLER-HAMMER MULTIPLE METERING STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120/240 VAC; 25 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 5000 AMPERE AT 24 TO 48 VDC; 3800 AMPERE AT 62.5 VDC; EXTENDED TANG LINE TERMINAL; BOX LUG LOAD TERMINAL TERMINAL
$18.46