E50DH1 CUTLER-HAMMER DISTRIBUTION EQUIPMENT/CONTROLS LIMIT SWITCH HEADS
SIDE PUSH BUTTON; OPERATION TYPE MAINTAINED; OPERATING FORCE 5 LB; 0.32 INCH TOTAL TRAVEL; 0.2 INCH OPERATING TRAVEL; 0.13 INCH RESET TRAVEL; OPERATING TEMPERATURE 14 TO 200 DEG F (WITH/WITHOUT CABLE); USED ON E50/E50 6P/10316 SERIES LIMIT SWITCH
$142.42 -
BAB1020S CUTLER-HAMMER MULTIPLE METERING STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120/240 VAC; 20 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 5000 AMPERE AT 24 TO 48 VDC; 3800 AMPERE AT 62.5 VDC; EXTENDED TANG LINE TERMINAL; BOX LUG LOAD TERMINAL TERMINAL
$142.72 -
C0050A2G CUTLER-HAMMER DRY TYPE TFMR CORE & COIL INDUSTRIAL CONTROL TRANSFORMERS
PRIMARY VOLTAGE 230/460 V; SECONDARY VOLTAGE 115/230 V; 60 HZ; POWER RATING 50 VA; SCREW TERMINAL; TEMPERATURE RISE 55 DEG C; SIZE 3 INCH W X 3-1/4 INCH D X 2-19/32 INCH H; APPLICABLE STANDARD ANSI; IEEE; NEMA ST-1; APPROVAL CSA; MTA MODEL
$143.52 -
BW2150 CUTLER-HAMMER CIRCUIT PROTECT DEV BASE MOUNT CIRCUIT BREAKERS
THERMAL MAGNETIC; MAIN; 2 POLE; 208 VAC STAR/120 VAC; 240 VAC; 150 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 2 AWG TO 300 KCMIL (ALUMINUM/COPPER); APPROVAL UL 489; USED ON LOAD CENTER
$145.24 -
BW2175 CUTLER-HAMMER CIRCUIT PROTECT DEV BASE MOUNT CIRCUIT BREAKERS
THERMAL MAGNETIC; MAIN; 2 POLE; 208 VAC STAR/120 VAC; 240 VAC; 175 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 2 AWG TO 300 KCMIL (ALUMINUM/COPPER); APPROVAL UL 489; USED ON LOAD CENTER
$145.24 -
BW2200 CUTLER HAMMER MAIN BREAKER 200 AMP
THERMAL MAGNETIC; MAIN; 2 POLE; 208 VAC STAR/120 VAC; 240 VAC; 200 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 2 AWG TO 300 KCMIL (ALUMINUM/COPPER); APPROVAL UL 489; USED ON LOAD CENTER
$145.24 -
BW2225 CUTLER-HAMMER MULTIPLE METERING BASE MOUNT CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 225 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; LINE TERMINAL TERMINAL; WIRE SIZE 2 AWG TO 300 KCMIL (ALUMINUM/COPPER); APPROVAL UL 489; USED ON LOAD CENTER
$145.24 -
BAB3025H CUTLER-HAMMER MULTIPLE METERING STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 3 POLE; 240 VAC; 25 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; EXTENDED TANG LINE TERMINAL TERMINAL; BOLT ON MOUNTING; APPROVAL UL 489; CSA; QUICKLAG[R] BRAND; BAB MODEL
$145.65 -
E57LBL12T111SD CUTLER-HAMMER DISTRIBUTION EQUIPMENT/CONTROLS INDUCTIVE PROXIMITY SENSORS
CONSTRUCTION THREADED BARREL; 10 TO 50 VDC OPERATING VOLTAGE; 3 WIRE; 200 MILLIAMPERE LOAD CURRENT; 1000 HZ SWITCHING FREQUENCY; END SENSING POSITION; 2 MM SENSING DISTANCE; OUTPUT CONFIGURATION NC; PNP; SHIELDED; 4 PIN MICRO DC CONNECTOR CONNECTION
$145.73 -
3463D94G04 CUTLER-HAMMER STARTER ACCESSORIES
AUXILIARY CONTACT; CONTACT CONFIGURATION 2NO; 5; 6 NEMA SIZE; USED ON STARTER
$147.55 -
GFCB220 CUTLER-HAMMER CIRCUIT PROTECT DEV GROUND FAULT GFCI PLUG-IN CIRCUIT BREAKERS
COMMON TRIP; 2 POLE; 120/240 VAC; 20 AMPERE; INTERRUPTING RATING 10000 AMPERE; 5 MILLIAMPERE TRIP SENSITIVITY; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; USED ON LOADCENTER; GFCB MODEL
$147.87 -
GFCB230 CUTLER-HAMMER CIRCUIT PROTECT DEV GROUND FAULT GFCI PLUG-IN CIRCUIT BREAKERS
COMMON TRIP; 2 POLE; 120/240 VAC; 30 AMPERE; INTERRUPTING RATING 10000 AMPERE; 5 MILLIAMPERE TRIP SENSITIVITY; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; USED ON LOADCENTER; GFCB MODEL
$147.87 -
GFCB240 CUTLER-HAMMER CIRCUIT PROTECT DEV GROUND FAULT GFCI PLUG-IN CIRCUIT BREAKERS
COMMON TRIP; 2 POLE; 120/240 VAC; 40 AMPERE; INTERRUPTING RATING 10000 AMPERE; 5 MILLIAMPERE TRIP SENSITIVITY; WIRE SIZE 14 TO 4 AWG (COPPER); PLUG ON MOUNTING; USED ON LOADCENTER; GFCB MODEL
$147.87 -
GFCB250 CUTLER-HAMMER CIRCUIT PROTECT DEV GROUND FAULT GFCI PLUG-IN CIRCUIT BREAKERS
COMMON TRIP; 2 POLE; 120/240 VAC; 50 AMPERE; INTERRUPTING RATING 10000 AMPERE; 5 MILLIAMPERE TRIP SENSITIVITY; WIRE SIZE 14 TO 4 AWG (COPPER); PLUG ON MOUNTING; USED ON LOADCENTER; GFCB MODEL
$147.87