QCF1020 CUTLER-HAMMER MULTIPLE METERING DIN RAIL MOUNT CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120/240 VAC; 20 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 3000 AMPERE AT 24 TO 48 VDC; 3800 AMPERE AT 62.5 VDC; BOX LUG TERMINAL; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); CABLE IN; CABLE OUT MOUNTING
$30.37 -
QCF1015 CUTLER-HAMMER MULTIPLE METERING DIN RAIL MOUNT CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120/240 VAC; 15 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 3000 AMPERE AT 24 TO 48 VDC; 3800 AMPERE AT 62.5 VDC; BOX LUG TERMINAL; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); CABLE IN; CABLE OUT MOUNTING
$51.75 -
QCD1020 CUTLER-HAMMER MULTIPLE METERING DIN RAIL MOUNT CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120/240 VAC; 20 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; SCREW TERMINAL; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER; LINE/LOAD); SIZE 12.5 INCH X 7.5 INCH X 5 INCH; APPROVAL UL 489; CSA; QCD MODEL
$56.30 -
QC3100H CUTLER-HAMMER MULTIPLE METERING DIN RAIL MOUNT CIRCUIT BREAKERS
THERMAL MAGNETIC; 3 POLE; 240 VAC; 100 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; BOX LUG TERMINAL; WIRE SIZE 14 TO 10 AWG ALUMINUM/COPPER (LINE); 8 TO 1/0 AWG ALUMINUM/COPPER (LOAD); CABLE IN; CABLE OUT MOUNTING; APPROVAL UL 489; CSA
$249.15 -
QC3090H CUTLER-HAMMER MULTIPLE METERING DIN RAIL MOUNT CIRCUIT BREAKERS
THERMAL MAGNETIC; 3 POLE; 240 VAC; 90 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; BOX LUG TERMINAL; WIRE SIZE 14 TO 10 AWG ALUMINUM/COPPER (LINE); 8 TO 1/0 AWG ALUMINUM/COPPER (LOAD); CABLE IN; CABLE OUT MOUNTING; APPROVAL UL 489; CSA
$249.15 -
QC3080H CUTLER-HAMMER MULTIPLE METERING DIN RAIL MOUNT CIRCUIT BREAKERS
THERMAL MAGNETIC; 3 POLE; 240 VAC; 80 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; BOX LUG TERMINAL; WIRE SIZE 14 TO 10 AWG ALUMINUM/COPPER (LINE); 8 TO 1/0 AWG ALUMINUM/COPPER (LOAD); CABLE IN; CABLE OUT MOUNTING; APPROVAL UL 489; CSA
$249.15 -
QC3070H CUTLER-HAMMER MULTIPLE METERING DIN RAIL MOUNT CIRCUIT BREAKERS
THERMAL MAGNETIC; 3 POLE; 240 VAC; 70 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; BOX LUG TERMINAL; WIRE SIZE 14 TO 10 AWG ALUMINUM/COPPER (LINE); 8 TO 1/0 AWG ALUMINUM/COPPER (LOAD); CABLE IN; CABLE OUT MOUNTING; APPROVAL UL 489; CSA
$221.59 -
QC3060H CUTLER-HAMMER MULTIPLE METERING DIN RAIL MOUNT CIRCUIT BREAKERS
THERMAL MAGNETIC; 3 POLE; 240 VAC; 60 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; BOX LUG TERMINAL; WIRE SIZE 14 TO 10 AWG ALUMINUM/COPPER (LINE); 14 TO 4 AWG ALUMINUM/COPPER (LOAD); CABLE IN; CABLE OUT MOUNTING; APPROVAL UL 489; CSA
$176.53 -
QC3050H CUTLER-HAMMER MULTIPLE METERING DIN RAIL MOUNT CIRCUIT BREAKERS
THERMAL MAGNETIC; 3 POLE; 240 VAC; 50 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; BOX LUG TERMINAL; WIRE SIZE 14 TO 10 AWG ALUMINUM/COPPER (LINE); 14 TO 4 AWG ALUMINUM/COPPER (LOAD); CABLE IN; CABLE OUT MOUNTING; APPROVAL UL 489; CSA
$176.53 -
QC3040H CUTLER-HAMMER MULTIPLE METERING DIN RAIL MOUNT CIRCUIT BREAKERS
THERMAL MAGNETIC; 3 POLE; 240 VAC; 40 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; BOX LUG TERMINAL; WIRE SIZE 14 TO 10 AWG ALUMINUM/COPPER (LINE); 14 TO 4 AWG ALUMINUM/COPPER (LOAD); CABLE IN; CABLE OUT MOUNTING; APPROVAL UL 489; CSA
$176.53 -
QC3030H CUTLER-HAMMER MULTIPLE METERING DIN RAIL MOUNT CIRCUIT BREAKERS
THERMAL MAGNETIC; 3 POLE; 240 VAC; 30 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; BOX LUG TERMINAL; WIRE SIZE 14 TO 10 AWG ALUMINUM/COPPER (LINE); 14 TO 4 AWG ALUMINUM/COPPER (LOAD); CABLE IN; CABLE OUT MOUNTING; APPROVAL UL 489; CSA
$176.53 -
QC3025H CUTLER-HAMMER MULTIPLE METERING DIN RAIL MOUNT CIRCUIT BREAKERS
THERMAL MAGNETIC; 3 POLE; 240 VAC; 25 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; BOX LUG TERMINAL; WIRE SIZE 14 TO 10 AWG ALUMINUM/COPPER (LINE); 14 TO 4 AWG ALUMINUM/COPPER (LOAD); CABLE IN; CABLE OUT MOUNTING; APPROVAL UL 489; CSA
$176.53 -
QC3020H CUTLER-HAMMER MULTIPLE METERING DIN RAIL MOUNT CIRCUIT BREAKERS
THERMAL MAGNETIC; 3 POLE; 240 VAC; 20 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; RING TERMINAL; WIRE SIZE 14 TO 10 AWG (ALUMINUM/COPPER; LINE); CABLE IN; CABLE OUT MOUNTING; APPROVAL UL 489; CSA; QUICKLAG[R] BRAND; QC MODEL
$176.53 -
QC3015H CUTLER-HAMMER MULTIPLE METERING DIN RAIL MOUNT CIRCUIT BREAKERS
THERMAL MAGNETIC; 3 POLE; 240 VAC; 15 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; RING TERMINAL; WIRE SIZE 14 TO 10 AWG (ALUMINUM/COPPER; LINE); CABLE IN; CABLE OUT MOUNTING; APPROVAL UL 489; CSA; QUICKLAG[R] BRAND; QC MODEL
$176.53 -
QC2100 CUTLER-HAMMER MULTIPLE METERING DIN RAIL MOUNT CIRCUIT BREAKERS
THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 100 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 5000 AMPERE AT 24 TO 48/62.5/80 VDC; BOX LUG TERMINAL; WIRE SIZE 14 TO 10 AWG ALUMINUM/COPPER (LINE); 8 TO 1/0 AWG ALUMINUM/COPPER (LOAD)
$140.56 -
QC2090 CUTLER-HAMMER MULTIPLE METERING DIN RAIL MOUNT CIRCUIT BREAKERS
THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 90 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 5000 AMPERE AT 24 TO 48/62.5/80 VDC; BOX LUG TERMINAL; WIRE SIZE 14 TO 10 AWG ALUMINUM/COPPER (LINE); 8 TO 1/0 AWG ALUMINUM/COPPER (LOAD)
$140.56 -
QC2080 CUTLER-HAMMER MULTIPLE METERING DIN RAIL MOUNT CIRCUIT BREAKERS
THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 80 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 5000 AMPERE AT 24 TO 48/62.5/80 VDC; BOX LUG TERMINAL; WIRE SIZE 14 TO 10 AWG ALUMINUM/COPPER (LINE); 8 TO 1/0 AWG ALUMINUM/COPPER (LOAD)
$140.56 -
QC2070 CUTLER HAMMER WESTINGHOUSE FEED THROUGH
THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 70 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 5000 AMPERE AT 24 TO 48/62.5/80 VDC; BOX LUG TERMINAL; WIRE SIZE 14 TO 10 AWG ALUMINUM/COPPER (LINE); 8 TO 1/0 AWG ALUMINUM/COPPER (LOAD)
$112.69 -
QC2060 CUTLER-HAMMER MULTIPLE METERING DIN RAIL MOUNT CIRCUIT BREAKERS
THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 60 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 5000 AMPERE AT 24 TO 48/62.5/80 VDC; BOX LUG TERMINAL; WIRE SIZE 14 TO 10 AWG ALUMINUM/COPPER (LINE); 14 TO 4 AWG ALUMINUM/COPPER (LOAD)
$56.41 -
QC2050 CUTLER-HAMMER MULTIPLE METERING DIN RAIL MOUNT CIRCUIT BREAKERS
THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 50 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 5000 AMPERE AT 24 TO 48/62.5/80 VDC; BOX LUG TERMINAL; WIRE SIZE 14 TO 10 AWG ALUMINUM/COPPER (LINE); 14 TO 4 AWG ALUMINUM/COPPER (LOAD)
$56.41 -
QC2045 CUTLER-HAMMER MULTIPLE METERING SUPPLEMENTARY PROTECTOR CIRCUIT BREAKERS
THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 45 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; ALUMINUM BOX LUG LINE TERMINAL; STEEL BOX LUG LOAD TERMINAL TERMINAL; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER; LOAD); CABLE IN; CABLE OUT MOUNTING; APPROVAL UL 489; CSA
$57.17 -
QC2040 CUTLER-HAMMER MULTIPLE METERING DIN RAIL MOUNT CIRCUIT BREAKERS
THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 40 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 5000 AMPERE AT 24 TO 48/62.5/80 VDC; BOX LUG TERMINAL; WIRE SIZE 14 TO 10 AWG ALUMINUM/COPPER (LINE); 14 TO 4 AWG ALUMINUM/COPPER (LOAD)
$56.41 -
QC2030H CUTLER-HAMMER MULTIPLE METERING DIN RAIL MOUNT CIRCUIT BREAKERS
THERMAL MAGNETIC; 2 POLE; 240 VAC; 30 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; BOX LUG TERMINAL; WIRE SIZE 14 TO 10 AWG ALUMINUM/COPPER (LINE); 14 TO 4 AWG ALUMINUM/COPPER (LOAD); CABLE IN; CABLE OUT MOUNTING; APPROVAL UL 489; CSA
$332.03 -
QC2030 CUTLER HAMMER WESTINGHOUSE FEED THROUGH
THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 30 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 5000 AMPERE AT 24 TO 48/62.5/80 VDC; BOX LUG TERMINAL; WIRE SIZE 14 TO 10 AWG ALUMINUM/COPPER (LINE); 14 TO 4 AWG ALUMINUM/COPPER (LOAD)
$56.41 -
QC2025 CUTLER-HAMMER MULTIPLE METERING DIN RAIL MOUNT CIRCUIT BREAKERS
THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 25 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 5000 AMPERE AT 24 TO 48/62.5/80 VDC; BOX LUG TERMINAL; WIRE SIZE 14 TO 10 AWG ALUMINUM/COPPER (LINE); 14 TO 4 AWG ALUMINUM/COPPER (LOAD)
$56.41