-
1 × $13.45
-
1 × $4.11
-
1 × $1,113.15
-
1 × $198.98
-
1 × $105.57
-
1 × $86.43
-
1 × $374.99
-
1 × $1,242.19
-
1 × $206.83
-
1 × $208.02
-
1 × $108.12
-
1 × $84.71
-
1 × $265.48
-
1 × $134.79
-
1 × $74.44
-
1 × $137.53
-
1 × $24.27
-
1 × $242.41
-
1 × $2.88
-
1 × $117.38
-
1 × $6,361.96
-
1 × $456.92
-
1 × $10,207.44
-
1 × $4.30
-
1 × $34.86
-
1 × $78.84
-
1 × $39.76
-
1 × $53.13
-
1 × $1.95
-
1 × $49.50
-
1 × $93.84
-
1 × $43.37
-
1 × $33.21
-
1 × $1,664.40
-
1 × $3.36
-
1 × $250.96
-
1 × $99.70
-
1 × $1,331.36
-
1 × $1,524.90
-
1 × $1,166.16
-
1 × $243.31
-
1 × $1.95
-
1 × $621.92
-
1 × $265.73
-
1 × $6.89
-
1 × $1,266.84
-
1 × $99.62
-
1 × $2,363.36
-
1 × $439.69
-
1 × $1,288.23
-
1 × $9.13
-
1 × $1,521.97
-
1 × $1,131.21
-
1 × $246.33
-
1 × $48.00
-
1 × $7.23
-
1 × $1,680.32
-
1 × $279.68
-
1 × $60.93
-
1 × $2.06
-
1 × $20.46
-
BQDPLD SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS CIRCUIT BREAKER ACCESSORIES
PADLOCKABLE; 1/2/3 POLE; OFF LOCKING PROVISION; USED ON BQD/CQD FRAME CIRCUIT BREAKER; SPEEDFAX[T] BRAND
$19.48 -
CED63B015 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
FUSELESS CURRENT LIMITING; THERMAL MAGNETIC; 3 POLE; 600 VAC; 500 VDC; 15 AMPERE AT 40 DEG C; INTERRUPTING RATING 200 KILOAMPERE AT 240/480 VAC; 100 KILOAMPERE AT 600 VAC; 50 KILOAMPERE AT 500 VDC (UL); LUG LOAD TERMINAL TERMINAL
$1,071.43 -
CED63B040 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
FUSELESS CURRENT LIMITING; THERMAL MAGNETIC; 3 POLE; 600 VAC; 500 VDC; 40 AMPERE AT 40 DEG C; INTERRUPTING RATING 200 KILOAMPERE AT 240/480 VAC; 100 KILOAMPERE AT 600 VAC; 50 KILOAMPERE AT 500 VDC (UL); LUG LOAD TERMINAL TERMINAL
$1,071.43 -
CED63B050 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
FUSELESS CURRENT LIMITING; THERMAL MAGNETIC; 3 POLE; 600 VAC; 500 VDC; 50 AMPERE AT 40 DEG C; INTERRUPTING RATING 200 KILOAMPERE AT 240/480 VAC; 100 KILOAMPERE AT 600 VAC; 50 KILOAMPERE AT 500 VDC (UL); LUG LOAD TERMINAL TERMINAL
$1,071.43 -
CED63B060 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
FUSELESS CURRENT LIMITING; THERMAL MAGNETIC; 3 POLE; 600 VAC; 500 VDC; 60 AMPERE AT 40 DEG C; INTERRUPTING RATING 200 KILOAMPERE AT 240/480 VAC; 100 KILOAMPERE AT 600 VAC; 50 KILOAMPERE AT 500 VDC (UL); LUG LOAD TERMINAL TERMINAL
$1,071.43 -
CED63B080 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
FUSELESS CURRENT LIMITING; THERMAL MAGNETIC; 3 POLE; 600 VAC; 500 VDC; 80 AMPERE AT 40 DEG C; INTERRUPTING RATING 200 KILOAMPERE AT 240/480 VAC; 100 KILOAMPERE AT 600 VAC; 50 KILOAMPERE AT 500 VDC (UL); LUG LOAD TERMINAL TERMINAL
$1,071.43 -
CFD63B225 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
FUSELESS CURRENT LIMITING; MOLDED CASE; THERMAL MAGNETIC; FD FRAME; 600 VAC AT 50/60 HZ; 500 VDC; 225 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 200 KILOAMPERE AT 240/480 VAC; 100 KILOAMPERE AT 600 VAC; 50 KILOAMPERE AT 500 VDC (UL)
$2,191.80 -
CQD230 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS DIN RAIL MOUNT CIRCUIT BREAKERS
THERMAL MAGNETIC; 2 POLE; 480 STAR/277 VAC AT 50/60 HZ; 125/250 VDC; 30 AMPERE AT 40 DEG C; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 STAR/277 VAC/250 VDC (UL); LUG TERMINAL; WIRE SIZE 12 TO 6 AWG ALUMINUM; 14 TO 6 AWG COPPER
$116.89 -
CQD240 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS DIN RAIL MOUNT CIRCUIT BREAKERS
THERMAL MAGNETIC; 2 POLE; 480 STAR/277 VAC AT 50/60 HZ; 125/250 VDC; 40 AMPERE AT 40 DEG C; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 STAR/277 VAC/250 VDC (UL); LUG TERMINAL; WIRE SIZE 12 TO 6 AWG ALUMINUM; 14 TO 6 AWG COPPER
$116.89 -
CQD250 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS DIN RAIL MOUNT CIRCUIT BREAKERS
THERMAL MAGNETIC; 2 POLE; 480 STAR/277 VAC AT 50/60 HZ; 125/250 VDC; 50 AMPERE AT 40 DEG C; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 STAR/277 VAC/250 VDC (UL); LUG TERMINAL; WIRE SIZE 6 TO 1/0 AWG ALUMINUM; 8 TO 1 AWG COPPER
$116.89 -
CQD115 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS DIN RAIL MOUNT CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 277 VAC AT 50/60 HZ; 125 VDC; 15 AMPERE AT 40 DEG C; INTERRUPTING RATING 65 KILOAMPERE AT 120 VAC; 14 KILOAMPERE AT 277 VAC/125 VDC (UL); LUG TERMINAL; WIRE SIZE 12 TO 6 AWG ALUMINUM; 14 TO 6 AWG COPPER
$51.94 -
CQD120 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS DIN RAIL MOUNT CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 277 VAC AT 50/60 HZ; 125 VDC; 20 AMPERE AT 40 DEG C; INTERRUPTING RATING 65 KILOAMPERE AT 120 VAC; 14 KILOAMPERE AT 277 VAC/125 VDC (UL); LUG TERMINAL; WIRE SIZE 12 TO 6 AWG ALUMINUM; 14 TO 6 AWG COPPER
$51.94 -
CQD260 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS DIN RAIL MOUNT CIRCUIT BREAKERS
THERMAL MAGNETIC; 2 POLE; 480 STAR/277 VAC AT 50/60 HZ; 125/250 VDC; 60 AMPERE AT 40 DEG C; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 STAR/277 VAC/250 VDC (UL); LUG TERMINAL; WIRE SIZE 6 TO 1/0 AWG ALUMINUM; 8 TO 1 AWG COPPER
$116.89 -
CQD3100 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS DIN RAIL MOUNT CIRCUIT BREAKERS
THERMAL MAGNETIC; 3 POLE; 480 STAR/277 VAC AT 50/60 HZ; 100 AMPERE AT 40 DEG C; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 STAR/277 VAC (UL); LUG TERMINAL; WIRE SIZE 6 TO 1/0 AWG ALUMINUM; 8 TO 1 AWG COPPER
$259.77 -
CQD315 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS DIN RAIL MOUNT CIRCUIT BREAKERS
THERMAL MAGNETIC; 3 POLE; 480 STAR/277 VAC AT 50/60 HZ; 15 AMPERE AT 40 DEG C; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 STAR/277 VAC (UL); LUG TERMINAL; WIRE SIZE 12 TO 6 AWG ALUMINUM; 14 TO 6 AWG COPPER
$203.03 -
CQD320 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS DIN RAIL MOUNT CIRCUIT BREAKERS
THERMAL MAGNETIC; 3 POLE; 480 STAR/277 VAC AT 50/60 HZ; 20 AMPERE AT 40 DEG C; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 STAR/277 VAC (UL); LUG TERMINAL; WIRE SIZE 12 TO 6 AWG ALUMINUM; 14 TO 6 AWG COPPER
$203.03 -
CQD340 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS DIN RAIL MOUNT CIRCUIT BREAKERS
THERMAL MAGNETIC; 3 POLE; 480 STAR/277 VAC AT 50/60 HZ; 40 AMPERE AT 40 DEG C; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 STAR/277 VAC (UL); LUG TERMINAL; WIRE SIZE 12 TO 6 AWG ALUMINUM; 14 TO 6 AWG COPPER
$203.03 -
CQD350 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS DIN RAIL MOUNT CIRCUIT BREAKERS
THERMAL MAGNETIC; 3 POLE; 480 STAR/277 VAC AT 50/60 HZ; 50 AMPERE AT 40 DEG C; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 STAR/277 VAC (UL); LUG TERMINAL; WIRE SIZE 6 TO 1/0 AWG ALUMINUM; 8 TO 1 AWG COPPER
$203.03 -
CQD360 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS DIN RAIL MOUNT CIRCUIT BREAKERS
THERMAL MAGNETIC; 3 POLE; 480 STAR/277 VAC AT 50/60 HZ; 60 AMPERE AT 40 DEG C; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 STAR/277 VAC (UL); LUG TERMINAL; WIRE SIZE 6 TO 1/0 AWG ALUMINUM; 8 TO 1 AWG COPPER
$203.03 -
CQD380 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS DIN RAIL MOUNT CIRCUIT BREAKERS
THERMAL MAGNETIC; 3 POLE; 480 STAR/277 VAC AT 50/60 HZ; 80 AMPERE AT 40 DEG C; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 STAR/277 VAC (UL); LUG TERMINAL; WIRE SIZE 6 TO 1/0 AWG ALUMINUM; 8 TO 1 AWG COPPER
$259.77 -
ED21B015 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120 VAC; 125 VDC; 15 AMPERE AT 40 DEG C; INTERRUPTING RATING 10 KILOAMPERE AT 120 VAC; 5 KILOAMPERE AT 125 VDC; LOAD LUG TERMINAL; WIRE SIZE 2/0 AWG (COMPRESSION LUG); 12 TO 10 AWG ALUMINUM; 14 TO 10 AWG COPPER (ALUMINUM LUG)
$51.95 -
ED21B030 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120 VAC; 125 VDC; 30 AMPERE AT 40 DEG C; INTERRUPTING RATING 10 KILOAMPERE AT 120 VAC; 5 KILOAMPERE AT 125 VDC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 4 AWG (ALUMINUM/COPPER); SIZE 1 INCH W X 4.56 INCH D X 6.35 INCH H
$51.95 -
ED21B040 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120 VAC; 125 VDC; 40 AMPERE AT 40 DEG C; INTERRUPTING RATING 10 KILOAMPERE AT 120 VAC; 5 KILOAMPERE AT 125 VDC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 4 AWG (ALUMINUM/COPPER); SIZE 1 INCH W X 4.56 INCH D X 6.35 INCH H
$51.95 -
ED23B020 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
THERMAL MAGNETIC; 3 POLE; 240 VAC; 20 AMPERE AT 40 DEG C; INTERRUPTING RATING 10 KILOAMPERE AT 240 VAC (UL); LUG LOAD TERMINAL TERMINAL; WIRE SIZE 12 TO 10 AWG (ALUMINUM); 14 TO 10 AWG (COPPER); SIZE 3 INCH W X 4.56 INCH D X 6.35 INCH H
$178.55