QOB245 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 45 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 8 TO 2 AWG (ALUMINUM/COPPER); BOLT ON MOUNTING
$97.41 -
QOB240VH SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 40 AMPERE; INTERRUPTING RATING 22 KILOAMPERE; WIRE SIZE 8 TO 2 AWG (ALUMINUM/COPPER); BOLT ON MOUNTING; SIZE 3 INCH W X 4.9 INCH D X 5.72 INCH H; APPROVAL UL; USED ON NQ PANELBOARD
$196.52 -
QOB240EPD SQUARE D/TELEMECANIQUE EQUIPMENT PROTECTION EPD BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 40 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 12 TO 4 AWG (ALUMINUM); 14 TO 6 AWG (COPPER); BOLT ON MOUNTING; SIZE 1.5 INCH W X 2.91 INCH D X 4.12 INCH H; APPROVAL UL
$1,237.63 -
QOB240 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 40 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 8 TO 2 AWG (ALUMINUM/COPPER); BOLT ON MOUNTING
$97.41 -
QOB235 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 35 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 8 TO 2 AWG (ALUMINUM/COPPER); BOLT ON MOUNTING
$97.41 -
QOB230VH SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 30 AMPERE; INTERRUPTING RATING 22 KILOAMPERE; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER); (2) 14 TO 10 AWG (COPPER); BOLT ON MOUNTING; SIZE 3 INCH W X 4.9 INCH D X 5.72 INCH H
$196.52 -
QOB230SWN SQUARE D/TELEMECANIQUE SPECIAL APPLICATION BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; 2 POLE; 120 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 30 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER); (2) 14 TO 10 AWG (COPPER); APPLICATION HACR
$123.44 -
QOB230HID SQUARE D/TELEMECANIQUE SPECIAL APPLICATION BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 30 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 14 TO 8 AWG (ALUMINUM); (2) 14 TO 10 AWG (COPPER)
$114.93 -
QOB2301021 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 30 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER); (2) 14 TO 10 AWG (COPPER)
$295.83 -
QOB230 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 30 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER); (2) 14 TO 10 AWG (COPPER)
$97.41 -
QOB220VH SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 20 AMPERE; INTERRUPTING RATING 22 KILOAMPERE; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER); (2) 14 TO 10 AWG (COPPER); BOLT ON MOUNTING; SIZE 3 INCH W X 4.9 INCH D X 5.72 INCH H
$196.52 -
QOB220SWN SQUARE D/TELEMECANIQUE SPECIAL APPLICATION BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; 2 POLE; 120 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 20 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER); (2) 14 TO 10 AWG (COPPER); APPLICATION HACR
$123.44 -
QOB220GFI SQUARE D/TELEMECANIQUE GROUND FAULT GFCI BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 20 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 12 TO 8 AWG (ALUMINUM); 14 TO 8 AWG (COPPER); BOLT ON MOUNTING; SIZE 1.5 INCH W X 2.91 INCH D X 4.12 INCH H; APPROVAL UL
$266.40 -
QOB220EPD SQUARE D/TELEMECANIQUE EQUIPMENT PROTECTION EPD BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 20 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 12 TO 8 AWG (ALUMINUM); 14 TO 8 AWG (COPPER); BOLT ON MOUNTING; SIZE 1.5 INCH W X 2.91 INCH D X 4.12 INCH H; APPROVAL UL
$1,237.63 -
QOB2201021 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 20 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER); (2) 14 TO 10 AWG (COPPER)
$295.83 -
QOB220 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 20 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER); (2) 14 TO 10 AWG (COPPER)
$97.41 -
QOB215VH SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 15 AMPERE; INTERRUPTING RATING 22 KILOAMPERE; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER); (2) 14 TO 10 AWG (COPPER); BOLT ON MOUNTING; SIZE 3 INCH W X 4.9 INCH D X 5.72 INCH H
$196.52 -
QOB215GFI SQUARE D/TELEMECANIQUE GROUND FAULT GFCI BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 15 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 12 TO 8 AWG (ALUMINUM); 14 TO 8 AWG (COPPER); BOLT ON MOUNTING; SIZE 1.5 INCH W X 2.91 INCH D X 4.12 INCH H; APPROVAL UL
$472.47 -
QOB215EPD SQUARE D/TELEMECANIQUE EQUIPMENT PROTECTION EPD BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 15 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 12 TO 8 AWG (ALUMINUM); 14 TO 8 AWG (COPPER); BOLT ON MOUNTING; SIZE 1.5 INCH W X 2.91 INCH D X 4.12 INCH H; APPROVAL UL
$1,237.63 -
QOB2150VH SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 150 AMPERE; INTERRUPTING RATING 22 KILOAMPERE; WIRE SIZE 4 AWG TO 300 KCMIL (ALUMINUM/COPPER); BOLT ON MOUNTING; SIZE 3 INCH W X 4.9 INCH D X 5.72 INCH H; APPROVAL UL
$1,405.55 -
QOB215 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 15 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER); (2) 14 TO 10 AWG (COPPER)
$97.41 -
QOB2125VH SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 125 AMPERE; INTERRUPTING RATING 22 KILOAMPERE; WIRE SIZE 4 AWG TO 300 KCMIL (ALUMINUM/COPPER); BOLT ON MOUNTING; SIZE 3 INCH W X 4.9 INCH D X 5.72 INCH H; APPROVAL UL
$1,275.68 -
QOB2125 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
BRANCH; 120/240 VAC AT 50/60 HZ; 208 VAC STAR/120 VAC AT 50/60 HZ; 120 VAC STAR/240 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 125 AMPERE; 2 POLE; INTERRUPTING RATING 10 KILOAMPERE AT 120 VAC; 10 KILOAMPERE AT 120 VAC STAR/240 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC
$575.78 -
QOB2110 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 110 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 4 TO 2/0 AWG (ALUMINUM/COPPER); BOLT ON MOUNTING
$575.78 -
QOB2100VH SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
BRANCH; 120/240 VAC AT 50/60 HZ; 208 VAC STAR/120 VAC AT 50/60 HZ; 120 VAC STAR/240 VAC AT 50/60 HZ (UL/CSA); 100 AMPERE; 2 POLE; INTERRUPTING RATING 22 KILOAMPERE AT 120 VAC; 22 KILOAMPERE AT 120 VAC STAR/240 VAC (UL/CSA); APPLICATION APPLIANCE; LIGHTING
$441.32