-
ME8CT2 SQUARE D/TELEMECANIQUE CIRCUIT BREAKER ACCESSORIES
800 AMPERE NEUTRAL CURRENT TRANSFORMER; USED ON MXL/MEL CIRCUIT BREAKER
$689.72 -
D10S1 SQUARE D/TELEMECANIQUE DISCONNECT MOTOR SWITCHES & ACCESSORIES
NON FUSIBLE; 600 V; 30 AMPERE; POWER RATING 5 HP AT 120 V; 10 HP AT 200 TO 240 V; 20 HP AT 480 V; 25 HP AT 600 V; 3 POLE; ROTARY HANDLE OPERATOR; HANDLE INCLUDED; LUG TERMINAL; CONDUCTOR MATERIAL COPPER; 14 TO 8 AWG CONDUCTOR; NEMA 1/3/3R/4/12
$689.89 -
LC2D25BD SQUARE D/TELEMECANIQUE IEC CONTACTORS
REVERSING; 3 POLE; 2 HP AT 115 VAC; 3 HP AT 230 VAC 1 PHASE; 7.5 HP AT 200/230 VAC; 15 HP AT 460 VAC; 20 HP AT 575 VAC 3 PHASE; INDUCTIVE CURRENT 25 AMPERE (AC-3); RESISTIVE CURRENT 40 AMPERE (AC-1); COIL VOLTAGE 24 VDC; AUXILIARY CONTACT 1NO-1NC; OPEN
$690.25 -
9049A6CS SQUARE D/TELEMECANIQUE
CENTER HOLE FLOAT; 316 STAINLESS STEEL FLOAT MATERIAL; 7 INCH DIA FLOAT SIZE; CONTENTS FLOAT; 5 FT STAINLESS STEEL ROD; (4) STAINLESS STEEL STOP; USED ON CLASS 9036/9038 TYPE A FLOAT SWITCH; 9049 MODEL
$690.619049A6CS SQUARE D/TELEMECANIQUE
$690.61 -
MHC44S SQUARE D/TELEMECANIQUE LIGHTING PANELBOARD FRONTS & TRIMS
WIDTH 20 INCH; HEIGHT 44 INCH; NEMA 1; SURFACE MOUNTING; USED ON 225 AMPERE NQOD MERCHANDISED MAIN BREAKER PANELBOARD; MONO-FLAT[R] BRAND
$692.07 -
LC1F1154 SQUARE D/TELEMECANIQUE IEC CONTACTORS
NON REVERSING; 4 POLE; 30 HP AT 200/208 VAC AT 50/60 HZ; 40 HP AT 220/240 VAC AT 50/60 HZ; 75 HP AT 460/480 VAC AT 50/60 HZ; 100 HP AT 575/600 VAC AT 50/60 HZ; INDUCTIVE CURRENT 115 AMPERE (AC-3); RESISTIVE CURRENT 200 AMPERE (AC-1); AUXILIARY CONTACT 1NO
$694.20 -
8536SCG2V03A SQUARE D/TELEMECANIQUE NEMA NON-COMBINATION STARTERS
FULL VOLTAGE; NON REVERSING; 3 HP AT 115 VAC 50/60 HZ; 5 HP AT 230 VAC 50/60 HZ; 36 AMPERE; 1 PHASE; COIL VOLTAGE 220 V AT 50 HZ; 240 V AT 60 HZ; SIZE NEMA 1P; NEMA 1 ENCLOSURE; OVERLOADS MELTING ALLOY; NEMA CONSTRUCTION STANDARD; 8536 MODEL
$695.98 -
FAL32020 SQUARE D LUG TO LUG BREAKER
MOLDED CASE; THERMAL MAGNETIC; F FRAME; 240 VAC AT 50/60 HZ (UL/CSA/NOM); 250 VDC; 20 AMPERE; 3 POLE; INTERRUPTING RATING 10 KILOAMPERE AT 240 VAC (UL/CSA/NOM); 5 KILOAMPERE AT 250 VDC; TERMINAL LINE LUG; LOAD LUG; SIZE 4.5 INCH W X 4.13 INCH D X 6 INCH H
$696.76 -
FAL32030 SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; F FRAME; 240 VAC AT 50/60 HZ (UL/CSA/NOM); 250 VDC; 30 AMPERE; 3 POLE; INTERRUPTING RATING 10 KILOAMPERE AT 240 VAC (UL/CSA/NOM); 5 KILOAMPERE AT 250 VDC; TERMINAL LINE LUG; LOAD LUG; SIZE 4.5 INCH W X 4.13 INCH D X 6 INCH H
$696.76 -
FAL32040 SQUARE D CIRCUIT BREAKER 240V 40 AMP
MOLDED CASE; THERMAL MAGNETIC; F FRAME; 240 VAC AT 50/60 HZ (UL/CSA/NOM); 250 VDC; 40 AMPERE; 3 POLE; INTERRUPTING RATING 10 KILOAMPERE AT 240 VAC (UL/CSA/NOM); 5 KILOAMPERE AT 250 VDC; TERMINAL LINE LUG; LOAD LUG; SIZE 4.5 INCH W X 4.13 INCH D X 6 INCH H
$696.76 -
FAL32050 SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; F FRAME; 240 VAC AT 50/60 HZ (UL/CSA/NOM); 250 VDC; 50 AMPERE; 3 POLE; INTERRUPTING RATING 10 KILOAMPERE AT 240 VAC (UL/CSA/NOM); 5 KILOAMPERE AT 250 VDC; TERMINAL LINE LUG; LOAD LUG; SIZE 4.5 INCH W X 4.13 INCH D X 6 INCH H
$696.76 -
8502SCW12V03 SQUARE D/TELEMECANIQUE NEMA CONTACTORS
FULL VOLTAGE; NON REVERSING; 3 POLE; 7 1/2 HP AT 200/230 VAC 50/60 HZ; 10 HP AT 460/575 VAC 50/60 HZ; 27 AMPERE; COIL VOLTAGE 220 V AT 50 HZ; 240 V AT 60 HZ; NEMA 4/4X; SIZE NEMA 1; NEMA CONSTRUCTION STANDARD; TESYS[R] BRAND; 8502 MODEL
$698.20 -
8536SBG2V81F4T SQUARE D/TELEMECANIQUE NEMA NON-COMBINATION STARTERS
FULL VOLTAGE; NON REVERSING; 3 HP AT 200/230 VAC 50/60 HZ; 5 HP AT 460/575 VAC 50/60 HZ; 18 AMPERE; 3 PHASE; COIL VOLTAGE 120 V AT 60 HZ; SIZE NEMA 0; NEMA 1 ENCLOSURE; OVERLOADS MELTING ALLOY; NEMA CONSTRUCTION STANDARD; 8536 MODEL; NUMBER OF POLE 3
$698.51 -
9037HW30 SQUARE D/TELEMECANIQUE FLOAT SWITCHES & ACCESSORIES
CLOSED TANK; 230 VAC 1 PHASE; 575 VAC 3 PHASE; 230 VDC; POWER RATING 3 HP AT 230 VAC 1 PHASE; 5 HP AT 230 VAC 3 PHASE; 1/2 HP AT 230 VDC; CONTACT VOLTAGE 120 TO 600 VAC; 125/250 VDC; CONTACT CONFIGURATION 2 POLE; 90 DEG OFFSET FLOAT ROD OPERATOR
$699.97 -
9037HW32 SQUARE D/TELEMECANIQUE FLOAT SWITCHES & ACCESSORIES
CLOSED TANK; 230 VAC 1 PHASE; 575 VAC 3 PHASE; 230 VDC; POWER RATING 3 HP AT 230 VAC 1 PHASE; 5 HP AT 230 VAC 3 PHASE; 1/2 HP AT 230 VDC; CONTACT VOLTAGE 120 TO 600 VAC; 125/250 VDC; CONTACT CONFIGURATION 2 POLE; 90 DEG OFFSET FLOAT ROD OPERATOR
$699.97 -
9037HW33 SQUARE D/TELEMECANIQUE FLOAT SWITCHES & ACCESSORIES
CLOSED TANK; 230 VAC 1 PHASE; 575 VAC 3 PHASE; 230 VDC; POWER RATING 3 HP AT 230 VAC 1 PHASE; 5 HP AT 230 VAC 3 PHASE; 1/2 HP AT 230 VDC; CONTACT VOLTAGE 120 TO 600 VAC; 125/250 VDC; CONTACT CONFIGURATION 2 POLE; 45 DEG OFFSET FLOAT ROD OPERATOR
$699.97 -
QBA221004 SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
240 VAC AT 50/60 HZ; 100 AMPERE; 2 POLE; INTERRUPTING RATING 10 KILOAMPERE AT 240 VAC (UL/CSA/NOM/IEC); 10 KILOAMPERE AT 240 VAC (IEC); TRIP SETTING 1200 TO 2400 AMPERE; APPLICATION POWER DISTRIBUTION
$702.72 -
QBA221251 SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
240 VAC AT 50/60 HZ; 125 AMPERE; 2 POLE; INTERRUPTING RATING 10 KILOAMPERE AT 240 VAC (UL/CSA/NOM/IEC); 10 KILOAMPERE AT 240 VAC (IEC); TRIP SETTING 1200 TO 2400 AMPERE; APPLICATION POWER DISTRIBUTION
$702.72 -
QBA221252 SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
240 VAC AT 50/60 HZ; 125 AMPERE; 2 POLE; INTERRUPTING RATING 10 KILOAMPERE AT 240 VAC (UL/CSA/NOM/IEC); 10 KILOAMPERE AT 240 VAC (IEC); TRIP SETTING 1200 TO 2400 AMPERE; APPLICATION POWER DISTRIBUTION
$702.72 -
QBA221502 SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
240 VAC AT 50/60 HZ; 150 AMPERE; 2 POLE; INTERRUPTING RATING 10 KILOAMPERE AT 240 VAC (UL/CSA/NOM/IEC); 10 KILOAMPERE AT 240 VAC (IEC); TRIP SETTING 1200 TO 2400 AMPERE; APPLICATION POWER DISTRIBUTION
$702.72 -
QBA222001 SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
240 VAC AT 50/60 HZ; 200 AMPERE; 2 POLE; INTERRUPTING RATING 10 KILOAMPERE AT 240 VAC (UL/CSA/NOM/IEC); 10 KILOAMPERE AT 240 VAC (IEC); TRIP SETTING 1200 TO 2400 AMPERE; APPLICATION POWER DISTRIBUTION
$702.72 -
QBA222002 SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
240 VAC AT 50/60 HZ; 200 AMPERE; 2 POLE; INTERRUPTING RATING 10 KILOAMPERE AT 240 VAC (UL/CSA/NOM/IEC); 10 KILOAMPERE AT 240 VAC (IEC); TRIP SETTING 1200 TO 2400 AMPERE; APPLICATION POWER DISTRIBUTION
$702.72 -
QBA222252 SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
240 VAC AT 50/60 HZ; 225 AMPERE; 2 POLE; INTERRUPTING RATING 10 KILOAMPERE AT 240 VAC (UL/CSA/NOM/IEC); 10 KILOAMPERE AT 240 VAC (IEC); TRIP SETTING 1200 TO 2400 AMPERE; APPLICATION POWER DISTRIBUTION
$702.72 -
9050AO22EV02 SQUARE D/TELEMECANIQUE TIMING RELAYS & ACCESSORIES
AC OPERATED; TIMED CONTACT CONFIGURATION 2NO-2NC; INSTANTANEOUS CONTACT CONFIGURATION 2NO-2NC; CONTACT RATING 120/240/480/600 VAC; 115/230/600 VDC 10 AMPERE; COIL VOLTAGE 110 VAC AT 50 HZ; 120 VAC AT 60 HZ; TIMING RANGE 0.1 SEC TO 1 MIN
$703.59