-
9422ART21 SQUARE D/TELEMECANIQUE DISCONNECT MOTOR SWITCHES & ACCESSORIES
6 INCH LEVER HANDLE; HANDLE INCLUDED; HANDLE MOUNTING LOCATION LEFT/RIGHT; MEL/MXL FRAME 800 AMPERE; MAL/MHL FRAME 1000 AMPERE BREAKER; HANDLE TO DEVICE CONNECTION 9 TO 18.38 INCH VARIABLE DEPTH SHAFT; NEMA 4/4X; 9422 MODEL; WITH TYPE A2 HANDLE MECHANISM
$1,536.59 -
8536SCG3V81CF4T SQUARE D/TELEMECANIQUE NEMA NON-COMBINATION STARTERS
FULL VOLTAGE; NON REVERSING; 7 1/2 HP AT 200/230 VAC 50/60 HZ; 10 HP AT 460/575 VAC 50/60 HZ; 27 AMPERE; 3 PHASE; COIL VOLTAGE 120 V AT 60 HZ; SIZE NEMA 1; NEMA 1 ENCLOSURE; OVERLOADS MELTING ALLOY; NEMA CONSTRUCTION STANDARD; 8536 MODEL; NUMBER OF POLE 3
$1,536.63 -
H361AWKEI2 SQUARE D/TELEMECANIQUE FUSIBLE HEAVY DUTY SAFETY SWITCHES
HEAVY DUTY SAFETY; 480/600 V AC VOLTAGE; 250/600 V DC VOLTAGE; 30 AMPERE; POWER RATING 5 HP AT 480 VAC 3 PHASE; 7 1/2 HP AT 600 VAC 3 PHASE (STANDARD); 15 HP AT 480 VAC 3 PHASE; 20 HP AT 600 VAC 3 PHASE (MAXIMUM); 5 HP AT 250 VDC; 15 HP AT 600 VDC; 3 POLE
$1,544.84 -
PQ3203G SQUARE D/TELEMECANIQUE BUSWAY FUSIBLE PLUG UNITS
CLASS J FUSE; 240 VAC; 30 AMPERE; 3 POLE; NO NEUTRAL; USED ON PLUG IN BUSWAY
$1,553.64 -
HLL36030 SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; H FRAME; 240 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ; 480 VAC AT 50/60 HZ; 600 VAC STAR/347 VAC AT 50/60 HZ; 600 VAC AT 50/60 HZ (UL/CSA/NOM); 240/415 VAC AT 50/60 HZ (IEC); 250 VDC; 30 AMPERE; 3 POLE
$1,555.55 -
8903SQO3V02 SQUARE D/TELEMECANIQUE LIGHTING CONTACTORS
ELECTRICALLY HELD; 4 POLE; 100 AMPERE; COIL VOLTAGE 110 V AT 50 HZ; 120 V AT 60 HZ; OPEN; NEMA CONSTRUCTION STANDARD; APPROVAL UL; CSA; SQUARE D[R] BRAND; 8903 MODEL
$1,560.99 -
8903LG1000V01 SQUARE D/TELEMECANIQUE LIGHTING CONTACTORS
ELECTRICALLY HELD; 10 POLE; 30 AMPERE; RESISTIVE CURRENT 30 AMPERE (FLUORESCENT LIGHTING); 20 AMPERE (TUNGSTEN LIGHTING); COIL VOLTAGE 24 V AT 60 HZ; NEMA 1; NEMA CONSTRUCTION STANDARD; APPROVAL UL; CSA; SQUARE D[R] BRAND; 8903 MODEL
$1,561.26 -
8940SSC4010 SQUARE D/TELEMECANIQUE NEMA COMBINATION STARTERS
FULL VOLTAGE; MOTOR/LINE VOLTAGE 480 VAC AT 50/60 HZ; POWER RATING 3; 5; 7 1/2; 10 HP; 3 PHASE; DISCONNECT TYPE FUSIBLE; DISCONNECT RATING 30 AMPERE; OVERLOADS CLASS 10 AMBIENT TEMPERATURE COMPENSATED; COIL VOLTAGE 440 V AT 50 HZ; 480 V AT 60 HZ; NEMA 3R
$1,562.34 -
H364NRB SQUARE D/TELEMECANIQUE FUSIBLE HEAVY DUTY SAFETY SWITCHES
HEAVY DUTY SAFETY; 480/600 V AC VOLTAGE; 250/600 V DC VOLTAGE; 200 AMPERE; POWER RATING 50 HP AT 480 VAC 3 PHASE; 60 HP AT 600 VAC 3 PHASE (STANDARD); 125 HP AT 480 VAC 3 PHASE; 150 HP AT 600 VAC 3 PHASE (MAXIMUM); 40 HP AT 250 VDC; 50 HP AT 600 VDC
$1,565.20 -
FAL36070 SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; F FRAME; 240 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ; 480 VAC AT 50/60 HZ; 600 VAC STAR/347 VAC AT 50/60 HZ; 600 VAC AT 50/60 HZ (UL/CSA/NOM); 415 VAC AT 50/60 HZ (IEC); 250 VDC; 70 AMPERE; 3 POLE
$1,569.47 -
FAL36080 SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; F FRAME; 240 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ; 480 VAC AT 50/60 HZ; 600 VAC STAR/347 VAC AT 50/60 HZ; 600 VAC AT 50/60 HZ (UL/CSA/NOM); 415 VAC AT 50/60 HZ (IEC); 250 VDC; 80 AMPERE; 3 POLE
$1,569.47 -
FAL36090 SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; F FRAME; 240 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ; 480 VAC AT 50/60 HZ; 600 VAC STAR/347 VAC AT 50/60 HZ; 600 VAC AT 50/60 HZ (UL/CSA/NOM); 415 VAC AT 50/60 HZ (IEC); 250 VDC; 90 AMPERE; 3 POLE
$1,569.47 -
FAL36100 SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; F FRAME; 240 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ; 480 VAC AT 50/60 HZ; 600 VAC STAR/347 VAC AT 50/60 HZ; 600 VAC AT 50/60 HZ (UL/CSA/NOM); 415 VAC AT 50/60 HZ (IEC); 250 VDC; 100 AMPERE; 3 POLE
$1,569.47 -
9991SGG8 SQUARE D/TELEMECANIQUE NEMA TYPE 1 METALLIC ENCLOSURES BOXES CABINETS
SURFACE MOUNT; NEMA 1; USED ON CLASS 8536 TYPE SGO STARTER; 9991 MODEL
$1,574.28 -
QMB361TW SQUARE D/TELEMECANIQUE SWITCHBOARD COMPONENTS
240/480/600 VAC; 30 AMPERE; POWER RATING 3 HP AT 240 VAC 3 PHASE; 5 HP AT 480 VAC 3 PHASE; 7-1/2 HP AT 600 VAC 3 PHASE (STANDARD); 7 1/2 HP AT 240 VAC 3 PHASE; 15 HP AT 480 VAC 3 PHASE; 20 HP AT 600 VAC 3 PHASE (MAXIMUM); 3 POLE; SIZE 4-1/2 INCH H
$1,582.52 -
QMB362TW SQUARE D FUSIBLE PANEL SWITCH
240/480/600 VAC; 60 AMPERE; POWER RATING 7-1/2 HP AT 240 VAC 3 PHASE; 15 HP AT 480/600 VAC 3 PHASE (STANDARD); 15 HP AT 240 VAC 3 PHASE; 30 HP AT 480 VAC 3 PHASE; 50 HP AT 600 VAC 3 PHASE (MAXIMUM); 3 POLE; SIZE 6 INCH H; USED ON QMB SERIES PANELBOARD
$1,582.52QMB362TW SQUARE D FUSIBLE PANEL SWITCH
$1,582.52 -
9070TF500D32 SQUARE D/TELEMECANIQUE CORE & COIL INDUSTRIAL CONTROL TRANSFORMERS
PRIMARY VOLTAGE 220/440/550 V; 230/460/575 V; 240/480/600 V; SECONDARY VOLTAGE 90/110 V; 95/115 V; 100/120 V; 50/60 HZ; POWER RATING 500 VA; SCREW TERMINAL; TEMPERATURE RISE 115 DEG C; PANEL MOUNTING; SIZE 5-1/4 INCH W X 5.66 INCH D X 5.73 INCH H
$1,583.08 -
8536SBW22V06A SQUARE D/TELEMECANIQUE NEMA NON-COMBINATION STARTERS
FULL VOLTAGE; NON REVERSING; 3 HP AT 200/230 VAC 50/60 HZ; 5 HP AT 460/575 VAC 50/60 HZ; 18 AMPERE; 3 PHASE; COIL VOLTAGE 440 V AT 50 HZ; 480 V AT 60 HZ; SIZE NEMA 0; NEMA 4X ENCLOSURE; OVERLOADS MELTING ALLOY; NEMA CONSTRUCTION STANDARD; 8536 MODEL
$1,583.55 -
8538SDG11V03 SQUARE D/TELEMECANIQUE NEMA COMBINATION STARTERS
FULL VOLTAGE; NON REVERSING; LINE VOLTAGE 208/240/480/600 VAC AT 50/60 HZ; 10 HP AT 208 VAC; 15 HP AT 240 VAC; 25 HP AT 480/600 VAC; 3 PHASE; COIL VOLTAGE 220 V AT 50 HZ; 240 V AT 60 HZ; SIZE NEMA 2; NEMA 1 ENCLOSURE; NON FUSIBLE; OVERLOADS MELTING ALLOY
$1,585.11 -
H364N SQUARE D/TELEMECANIQUE FUSIBLE HEAVY DUTY SAFETY SWITCHES
HEAVY DUTY SAFETY; 480/600 V AC VOLTAGE; 250/600 V DC VOLTAGE; 200 AMPERE; POWER RATING 50 HP AT 480 VAC 3 PHASE; 60 HP AT 600 VAC 3 PHASE (STANDARD); 125 HP AT 480 VAC 3 PHASE; 150 HP AT 600 VAC 3 PHASE (MAXIMUM); 40 HP AT 250 VDC; 50 HP AT 600 VDC
$1,588.65 -
8736SDO2V02S SQUARE D/TELEMECANIQUE NEMA NON-COMBINATION STARTERS
FULL VOLTAGE; REVERSING; 10 HP AT 200 VAC 50/60 HZ; 15 HP AT 230 VAC 50/60 HZ; 25 HP AT 460/575 VAC 50/60 HZ; 45 AMPERE; 3 PHASE; COIL VOLTAGE 110 V AT 50 HZ; 120 V AT 60 HZ; SIZE NEMA 2; OPEN ENCLOSURE; OVERLOADS MELTING ALLOY THERMAL OVERLOAD RELAY
$1,589.80 -
EJB34015 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 3 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 15 AMPERE; INTERRUPTING RATING 100 KILOAMPERE AT 120/240 VAC; 65 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$1,590.49 -
EJB34020 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 3 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 20 AMPERE; INTERRUPTING RATING 100 KILOAMPERE AT 120/240 VAC; 65 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$1,590.49 -
EJB34030 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 3 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 30 AMPERE; INTERRUPTING RATING 100 KILOAMPERE AT 120/240 VAC; 65 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$1,590.49