FA34015 SQUARE D ILINE BREAKER
240/480 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA/NOM); 240/415 VAC AT 50/60 HZ (IEC); 250 VDC; 15 AMPERE; 3 POLE; INTERRUPTING RATING 25 KILOAMPERE AT 240 VAC; 18 KILOAMPERE AT 480 VAC STAR/277 VAC OR 480 VAC (UL/CSA/NOM)
$977.11FA34015 SQUARE D ILINE BREAKER
$977.11 -
FA32020 SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
240 VAC AT 50/60 HZ; 20 AMPERE; 3 POLE; INTERRUPTING RATING 25 KILOAMPERE AT 240 VAC (UL/CSA/NOM); TRIP SETTING 275 TO 600 AMPERE; APPLICATION POWER DISTRIBUTION; USED ON CLASS 650/651 I-LINE[R] PANELBOARD/SWITCHBOARD; APPROVAL UL; CSA; FA MODEL
$670.96 -
FA26100AC SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; F FRAME; 240 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ; 480 VAC AT 50/60 HZ; 600 VAC STAR/347 VAC AT 50/60 HZ; 600 VAC AT 50/60 HZ (UL/CSA/NOM); 415 VAC AT 50/60 HZ (IEC); 250 VDC; 100 AMPERE; 2 POLE
$1,110.83 -
FA26060AC SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; F FRAME; 240 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ; 480 VAC AT 50/60 HZ; 600 VAC STAR/347 VAC AT 50/60 HZ; 600 VAC AT 50/60 HZ (UL/CSA/NOM); 415 VAC AT 50/60 HZ (IEC); 250 VDC; 60 AMPERE; 2 POLE
$914.94 -
FA26040AC SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; F FRAME; 240 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ; 480 VAC AT 50/60 HZ; 600 VAC STAR/347 VAC AT 50/60 HZ; 600 VAC AT 50/60 HZ (UL/CSA/NOM); 415 VAC AT 50/60 HZ (IEC); 250 VDC; 40 AMPERE; 2 POLE
$914.94 -
FA26030AC SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; F FRAME; 240 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ; 480 VAC AT 50/60 HZ; 600 VAC STAR/347 VAC AT 50/60 HZ; 600 VAC AT 50/60 HZ (UL/CSA/NOM); 415 VAC AT 50/60 HZ (IEC); 250 VDC; 30 AMPERE; 2 POLE
$914.94 -
FA24070AB SQUARE D BREAKER (FA24070 B C PHASES)
240/480 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA/NOM); 240/415 VAC AT 50/60 HZ (IEC); 250 VDC; 70 AMPERE; 2 POLE; INTERRUPTING RATING 25 KILOAMPERE AT 240 VAC; 18 KILOAMPERE AT 480 VAC STAR/277 VAC OR 480 VAC (UL/CSA/NOM)
$977.11 -
FA24015AC SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
240/480 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA/NOM); 240/415 VAC AT 50/60 HZ (IEC); 250 VDC; 15 AMPERE; 2 POLE; INTERRUPTING RATING 25 KILOAMPERE AT 240 VAC; 18 KILOAMPERE AT 480 VAC STAR/277 VAC OR 480 VAC (UL/CSA/NOM)
$763.62 -
FA22020CB SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; F FRAME; 240 VAC AT 50/60 HZ (UL/CSA/NOM); 250 VDC; 20 AMPERE; 2 POLE; INTERRUPTING RATING 10 KILOAMPERE AT 240 VAC (UL/CSA/NOM); 5 KILOAMPERE AT 250 VDC; TERMINAL PLUG ON; SIZE 3 INCH W X 4.13 INCH D X 6 INCH H
$466.85 -
FA22020BC SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
240 VAC AT 50/60 HZ; 20 AMPERE; 2 POLE; INTERRUPTING RATING 25 KILOAMPERE AT 240 VAC (UL/CSA/NOM); TRIP SETTING 275 TO 600 AMPERE; APPLICATION POWER DISTRIBUTION; USED ON CLASS 650/651 I-LINE[R] PANELBOARD/SWITCHBOARD; APPROVAL UL; CSA; FA MODEL
$466.85 -
FA14100C SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
240/277 VAC AT 50/60 HZ (UL/CSA/NOM); 240 VAC AT 50/60 HZ (IEC); 125 VDC; 100 AMPERE; 1 POLE; INTERRUPTING RATING 25 KILOAMPERE AT 240 VAC (UL/CSA/NOM); 18 KILOAMPERE AT 240 VAC (IEC); TRIP SETTING 900 TO 1700 AMPERE; APPLICATION POWER DISTRIBUTION
$389.44 -
FA14100A SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
240/277 VAC AT 50/60 HZ (UL/CSA/NOM); 240 VAC AT 50/60 HZ (IEC); 125 VDC; 100 AMPERE; 1 POLE; INTERRUPTING RATING 25 KILOAMPERE AT 240 VAC (UL/CSA/NOM); 18 KILOAMPERE AT 240 VAC (IEC); TRIP SETTING 900 TO 1700 AMPERE; APPLICATION POWER DISTRIBUTION
$389.44 -
FA100RB SQUARE D/TELEMECANIQUE CIRCUIT BREAKER ENCLOSURES
BREAKER; 1; 2; 3 POLE FAL/FHL/FCL BREAKER; 15 TO 100 AMPERE BREAKER/SWITCH CURRENT RATING; 8.88 INCH W X 4.88 INCH D X 18 INCH H SIZE; NEMA 3R ENCLOSURE; STEEL MATERIAL; SURFACE MOUNTING; APPROVAL UL; CSA
$586.50 -
FA100DS SQUARE D/TELEMECANIQUE CIRCUIT BREAKER ENCLOSURES
BREAKER; 1; 2; 3 POLE FAL/FHL/FCL BREAKER; 15 TO 100 AMPERE BREAKER/SWITCH CURRENT RATING; 9.13 INCH W X 4.88 INCH D X 19.5 INCH H SIZE; NEMA 3/3R/4/4X/5 ENCLOSURE; STAINLESS STEEL MATERIAL; SURFACE MOUNTING; APPROVAL UL; CSA
$1,255.27 -
EME3084 SQUARE D/TELEMECANIQUE POWER METERS
ENHANCED ENERGY METE
$1,724.12 -
EK3062 SQUARE D/TELEMECANIQUE SAFETY SWITCH ACCESSORIES
SWITCH VOLTAGE RATING 240/600 VAC; 250/600 VDC; SWITCH CURRENT RATING 60 AMPERE; CONTACT CONFIGURATION 2NO-2NC; USED ON HEAVY DUTY SAFETY SWITCH
$235.44 -
EK3061 SQUARE D/TELEMECANIQUE SAFETY SWITCH ACCESSORIES
SWITCH VOLTAGE RATING 240/600 VAC; 250/600 VDC; SWITCH CURRENT RATING 60 AMPERE; CONTACT CONFIGURATION 1NO-1NC; USED ON HEAVY DUTY SAFETY SWITCH
$156.96 -
EK3002 SQUARE D/TELEMECANIQUE SAFETY SWITCH ACCESSORIES
SWITCH VOLTAGE RATING 240/600 VAC; 250/600 VDC; SWITCH CURRENT RATING 30 AMPERE; CONTACT CONFIGURATION 2NO-2NC; USED ON HEAVY DUTY SAFETY SWITCH
$235.44 -
EK3001 SQUARE D/TELEMECANIQUE SAFETY SWITCH ACCESSORIES
SWITCH VOLTAGE RATING 240/600 VAC; 250/600 VDC; SWITCH CURRENT RATING 30 AMPERE; CONTACT CONFIGURATION 1NO-1NC; USED ON HEAVY DUTY SAFETY SWITCH
$156.96 -
EK200DTU2 SQUARE D/TELEMECANIQUE SAFETY SWITCH ACCESSORIES
SWITCH VOLTAGE RATING 240/600 VAC; 250 VDC; SWITCH CURRENT RATING 200/600 AMPERE; CONTACT CONFIGURATION DOUBLE THROW; USED ON CLASS 3140 NEMA 1 DOUBLE THROW SAFETY SWITCH
$304.98 -
EK10202 SQUARE D/TELEMECANIQUE SAFETY SWITCH ACCESSORIES
SWITCH VOLTAGE RATING 240/600 VAC; 250/600 VDC; SWITCH CURRENT RATING 100 TO 200 AMPERE; CONTACT CONFIGURATION 2NO-2NC; USED ON HEAVY DUTY SAFETY SWITCH
$394.20 -
EK10201 SQUARE D/TELEMECANIQUE SAFETY SWITCH ACCESSORIES
SWITCH VOLTAGE RATING 240/600 VAC; 250/600 VDC; SWITCH CURRENT RATING 100 TO 200 AMPERE; CONTACT CONFIGURATION 1NO-1NC; USED ON HEAVY DUTY SAFETY SWITCH
$262.80 -
EJB34100 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 3 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 100 AMPERE; INTERRUPTING RATING 100 KILOAMPERE AT 120/240 VAC; 65 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$3,000.61 -
EJB34090 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 3 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 90 AMPERE; INTERRUPTING RATING 100 KILOAMPERE AT 120/240 VAC; 65 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$3,000.61 -
EJB34080 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 3 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 80 AMPERE; INTERRUPTING RATING 100 KILOAMPERE AT 120/240 VAC; 65 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$3,000.61