1 × $1,284.29
-
1 × $1,097.93
-
1 × $299.75
-
1 × $82.70
-
1 × $2,036.33
-
1 × $2.12
-
1 × $52.97
-
1 × $60.00
-
1 × $320.26
-
1 × $1,205.15
-
1 × $1,068.60
-
1 × $8.74
-
1 × $1,275.29
-
1 × $2,363.36
-
1 × $783.53
-
1 × $11.33
-
1 × $91.04
-
1 × $24,982.55
-
1 × $168.88
-
1 × $150.77
-
1 × $44.27
-
1 × $112.01
-
1 × $366.66
-
1 × $191.80
-
1 × $92.08
-
1 × $489.56
-
1 × $1,869.76
-
1 × $2,169.11
-
1 × $1,024.53
-
1 × $17.14
-
1 × $456.52
-
EIK031 SQUARE D/TELEMECANIQUE SAFETY SWITCH ACCESSORIES
SWITCH VOLTAGE RATING 240/600 VAC; 250/600 VDC; SWITCH CURRENT RATING 30/60 AMPERE; CONTACT CONFIGURATION 1NO-1NC; USED ON HEAVY DUTY SAFETY SWITCH
$156.96 -
EGB34125 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 3 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 125 AMPERE; INTERRUPTING RATING 65 KILOAMPERE AT 120/240 VAC; 35 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$3,766.58 -
EGB34100 SQUARE D BREAKER
THERMAL MAGNETIC; BRANCH; 3 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 100 AMPERE; INTERRUPTING RATING 65 KILOAMPERE AT 120/240 VAC; 35 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$1,513.19EGB34100 SQUARE D BREAKER
$1,513.19 -
EGB34090 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 3 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 90 AMPERE; INTERRUPTING RATING 65 KILOAMPERE AT 120/240 VAC; 35 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$1,513.19 -
EGB34080 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 3 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 80 AMPERE; INTERRUPTING RATING 65 KILOAMPERE AT 120/240 VAC; 35 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$1,513.19 -
EGB34070 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 3 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 70 AMPERE; INTERRUPTING RATING 65 KILOAMPERE AT 120/240 VAC; 35 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$1,513.19 -
EGB34060 SQUARE D CIRCUIT BREAKER
THERMAL MAGNETIC; BRANCH; 3 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 60 AMPERE; INTERRUPTING RATING 65 KILOAMPERE AT 120/240 VAC; 35 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$1,324.63EGB34060 SQUARE D CIRCUIT BREAKER
$1,324.63 -
EGB34040 SQUARE D BREAKER
THERMAL MAGNETIC; BRANCH; 3 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 40 AMPERE; INTERRUPTING RATING 65 KILOAMPERE AT 120/240 VAC; 35 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$1,324.63EGB34040 SQUARE D BREAKER
$1,324.63 -
EGB34035 SQUARE D BREAKER
THERMAL MAGNETIC; BRANCH; 3 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 35 AMPERE; INTERRUPTING RATING 65 KILOAMPERE AT 120/240 VAC; 35 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$1,324.63EGB34035 SQUARE D BREAKER
$1,324.63 -
EGB34030 SQUARE D BREAKER
THERMAL MAGNETIC; BRANCH; 3 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 30 AMPERE; INTERRUPTING RATING 65 KILOAMPERE AT 120/240 VAC; 35 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$1,324.63EGB34030 SQUARE D BREAKER
$1,324.63 -
EGB34025 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 3 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 25 AMPERE; INTERRUPTING RATING 65 KILOAMPERE AT 120/240 VAC; 35 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$1,324.63 -
EGB24100 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 2 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 100 AMPERE; INTERRUPTING RATING 65 KILOAMPERE AT 120/240 VAC; 35 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$1,499.14 -
EGB24080 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 2 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 80 AMPERE; INTERRUPTING RATING 65 KILOAMPERE AT 120/240 VAC; 35 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$1,499.14 -
EGB24070 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 2 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 70 AMPERE; INTERRUPTING RATING 65 KILOAMPERE AT 120/240 VAC; 35 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$1,499.14 -
EGB24060 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 2 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 60 AMPERE; INTERRUPTING RATING 65 KILOAMPERE AT 120/240 VAC; 35 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$908.85 -
EGB24050 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 2 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 50 AMPERE; INTERRUPTING RATING 65 KILOAMPERE AT 120/240 VAC; 35 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$908.85 -
EGB24040 SQUARE D BOLT ON BREAKER
THERMAL MAGNETIC; BRANCH; 2 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 40 AMPERE; INTERRUPTING RATING 65 KILOAMPERE AT 120/240 VAC; 35 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$908.85 -
EGB24035 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 2 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 35 AMPERE; INTERRUPTING RATING 65 KILOAMPERE AT 120/240 VAC; 35 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$908.85 -
EGB24030 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 2 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 30 AMPERE; INTERRUPTING RATING 65 KILOAMPERE AT 120/240 VAC; 35 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$908.85 -
EGB24025 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 2 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 25 AMPERE; INTERRUPTING RATING 65 KILOAMPERE AT 120/240 VAC; 35 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$908.85 -
EGB24020 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 2 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 20 AMPERE; INTERRUPTING RATING 65 KILOAMPERE AT 120/240 VAC; 35 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$908.85 -
EGB24015 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 2 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 15 AMPERE; INTERRUPTING RATING 65 KILOAMPERE AT 120/240 VAC; 35 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$908.85 -
EGB14040 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 1 POLE; 120/240/277 VAC AT 50/60 HZ (UL/CSA); 40 AMPERE; INTERRUPTING RATING 65 KILOAMPERE AT 120 VAC; 35 KILOAMPERE AT 120/240/277 VAC (UL/CSA); WIRE SIZE 14 TO 2/0 AWG (ALUMINUM/COPPER)
$298.66 -
EGB14030 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 1 POLE; 120/240/277 VAC AT 50/60 HZ (UL/CSA); 30 AMPERE; INTERRUPTING RATING 65 KILOAMPERE AT 120 VAC; 35 KILOAMPERE AT 120/240/277 VAC (UL/CSA); WIRE SIZE 14 TO 6 AWG (ALUMINUM/COPPER)
$298.66