EDB34060 SQUARE D
THERMAL MAGNETIC; BRANCH; 3 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 60 AMPERE; INTERRUPTING RATING 25 KILOAMPERE AT 120/240 VAC; 18 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$783.53EDB34060 SQUARE D
$783.53 -
EDB34050 SQUARE D CIRCUIT BREAKER
THERMAL MAGNETIC; BRANCH; 3 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 50 AMPERE; INTERRUPTING RATING 25 KILOAMPERE AT 120/240 VAC; 18 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$783.53 -
EDB34045 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 3 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 45 AMPERE; INTERRUPTING RATING 25 KILOAMPERE AT 120/240 VAC; 18 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$783.53 -
EDB34040 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 3 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 40 AMPERE; INTERRUPTING RATING 25 KILOAMPERE AT 120/240 VAC; 18 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$783.53 -
EDB34035 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 3 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 35 AMPERE; INTERRUPTING RATING 25 KILOAMPERE AT 120/240 VAC; 18 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$783.53 -
EDB34030 SQUARE D BOLT ON BREAKER
THERMAL MAGNETIC; BRANCH; 3 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 30 AMPERE; INTERRUPTING RATING 25 KILOAMPERE AT 120/240 VAC; 18 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$783.53 -
EDB34025 SQUARE D BREAKER
THERMAL MAGNETIC; BRANCH; 3 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 25 AMPERE; INTERRUPTING RATING 25 KILOAMPERE AT 120/240 VAC; 18 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$783.53EDB34025 SQUARE D BREAKER
$783.53 -
EDB34015 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 3 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 15 AMPERE; INTERRUPTING RATING 25 KILOAMPERE AT 120/240 VAC; 18 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$783.53 -
EDB24125 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 2 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 125 AMPERE; INTERRUPTING RATING 25 KILOAMPERE AT 120/240 VAC; 18 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$2,279.16 -
EDB24100 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 2 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 100 AMPERE; INTERRUPTING RATING 25 KILOAMPERE AT 120/240 VAC; 18 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$885.43 -
EDB24090 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 2 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 90 AMPERE; INTERRUPTING RATING 25 KILOAMPERE AT 120/240 VAC; 18 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$1,328.14 -
EDB24080 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 2 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 80 AMPERE; INTERRUPTING RATING 25 KILOAMPERE AT 120/240 VAC; 18 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$885.43 -
EDB24070 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 2 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 70 AMPERE; INTERRUPTING RATING 25 KILOAMPERE AT 120/240 VAC; 18 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$885.43 -
EDB24060 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 2 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 60 AMPERE; INTERRUPTING RATING 25 KILOAMPERE AT 120/240 VAC; 18 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$627.76 -
EDB24050 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 2 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 50 AMPERE; INTERRUPTING RATING 25 KILOAMPERE AT 120/240 VAC; 18 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$627.76 -
EDB24045 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 2 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 45 AMPERE; INTERRUPTING RATING 25 KILOAMPERE AT 120/240 VAC; 18 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$627.76 -
EDB24040 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 2 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 40 AMPERE; INTERRUPTING RATING 25 KILOAMPERE AT 120/240 VAC; 18 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$628.73 -
EDB24035 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 2 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 35 AMPERE; INTERRUPTING RATING 25 KILOAMPERE AT 120/240 VAC; 18 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$627.76 -
EDB24030 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 2 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 30 AMPERE; INTERRUPTING RATING 25 KILOAMPERE AT 120/240 VAC; 18 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$627.76 -
EDB24025 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 2 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 25 AMPERE; INTERRUPTING RATING 25 KILOAMPERE AT 120/240 VAC; 18 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$627.76 -
EDB24020 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 2 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 20 AMPERE; INTERRUPTING RATING 25 KILOAMPERE AT 120/240 VAC; 18 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$627.76 -
EDB24015 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 2 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 15 AMPERE; INTERRUPTING RATING 25 KILOAMPERE AT 120/240 VAC; 18 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$627.76 -
EDB14060 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 1 POLE; 120/240/277 VAC AT 50/60 HZ (UL/CSA); 240/415 VAC AT 50/60 HZ (IEC); 60 AMPERE; INTERRUPTING RATING 25 KILOAMPERE AT 120 VAC; 18 KILOAMPERE AT 120/240/277 VAC (UL/CSA)
$175.68 -
EDB14050 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 1 POLE; 120/240/277 VAC AT 50/60 HZ (UL/CSA); 240/415 VAC AT 50/60 HZ (IEC); 50 AMPERE; INTERRUPTING RATING 25 KILOAMPERE AT 120 VAC; 18 KILOAMPERE AT 120/240/277 VAC (UL/CSA)
$175.68 -
EDB14040 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 1 POLE; 120/240/277 VAC AT 50/60 HZ (UL/CSA); 240/415 VAC AT 50/60 HZ (IEC); 40 AMPERE; INTERRUPTING RATING 25 KILOAMPERE AT 120 VAC; 18 KILOAMPERE AT 120/240/277 VAC (UL/CSA)
$175.68