8903LO80V02 SQUARE D/TELEMECANIQUE LIGHTING CONTACTORS
ELECTRICALLY HELD; 8 POLE; 30 AMPERE; RESISTIVE CURRENT 30 AMPERE (FLUORESCENT LIGHTING); 20 AMPERE (TUNGSTEN LIGHTING); COIL VOLTAGE 110 V AT 50 HZ; 120 V AT 60 HZ; OPEN; NEMA CONSTRUCTION STANDARD; APPROVAL UL; CSA; SQUARE D[R] BRAND; 8903 MODEL
$826.89 -
FAL2601513M SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; F FRAME; 240 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ; 480 VAC AT 50/60 HZ; 600 VAC STAR/347 VAC AT 50/60 HZ; 600 VAC AT 50/60 HZ (UL/CSA/NOM); 415 VAC AT 50/60 HZ (IEC); 250 VDC; 15 AMPERE; 2 POLE
$825.79 -
FAL321006153 SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; F FRAME; 240 VAC AT 50/60 HZ (UL/CSA/NOM); 250 VDC; 100 AMPERE; 3 POLE; INTERRUPTING RATING 10 KILOAMPERE AT 240 VAC (UL/CSA/NOM); 5 KILOAMPERE AT 250 VDC; TERMINAL LINE LUG; LOAD LUG
$825.79 -
2510MCW11 SQUARE D/TELEMECANIQUE MANUAL STARTERS
NON REVERSING; 1 PHASE RATING 2 HP AT 115 V; 3 HP AT 230 V; 2 POLE; SIZE NEMA M1; NEMA 4 ENCLOSURE; PUSHBUTTON OPERATOR; OVERLOADS MELTING ALLOY; 2510 MODEL; APPROVAL UL; CSA
$824.87 -
2510MCW1 SQUARE D/TELEMECANIQUE MANUAL STARTERS
NON REVERSING; 1 PHASE RATING 2 HP AT 115 V; 3 HP AT 230 V; 2 POLE; SIZE NEMA M1; NEMA 4X ENCLOSURE; PUSHBUTTON OPERATOR; OVERLOADS MELTING ALLOY; 2510 MODEL; APPROVAL UL; CSA
$824.87 -
HU362EI SQUARE D/TELEMECANIQUE NON-FUSIBLE HEAVY DUTY SAFETY SWITCHES
HEAVY DUTY SAFETY; 240/480/600 V AC VOLTAGE; 250/600 V DC VOLTAGE; 60 AMPERE; POWER RATING 10 HP AT 240 VAC 1 PHASE; 20 HP AT 240 VAC 3 PHASE; 25 HP AT 480 VAC 1 PHASE; 50 HP AT 480 VAC 3 PHASE; 30 HP AT 600 VAC 1 PHASE; 60 HP AT 600 VAC 3 PHASE
$822.80 -
9012GFWM4 SQUARE D/TELEMECANIQUE PRESSURE SWITCHES
NON ADJUSTABLE DIFFERENTIAL; 440 STAINLESS STEEL PISTON WITH VITON DIAPHRAGM OPERATOR; OPERATING PRESSURE RATING 270 TO 9000 PSIG; MAXIMUM LINE PRESSURE RATING 25000 PSIG; DIFFERENTIAL PRESSURE RATING 495 +/- 70 PSIG; PRESSURE MEDIA ANY GAS/LIQUID
$821.10 -
XPSMP11123P SQUARE D/TELEMECANIQUE MONITORING RELAYS & ACCESSORIES
24 VDC; CONTACT CONFIGURATION 6NO; 6 STANDARD CIRCUIT; 12 LED DISPLAY; SCREW CLAMP TERMINAL; OPERATING TEMPERATURE 14 TO 130 DEG F; APPROVAL UL; CSA; CE; PREVENTA[T] BRAND; XPSMP MODEL; ADDITIONAL OUTPUT 3 SOLID STATE
$820.46 -
9012GNG1 SQUARE D/TELEMECANIQUE PRESSURE SWITCHES
ADJUSTABLE DIFFERENTIAL; BUNA N DIAPHRAGM OPERATOR; OPERATING PRESSURE RATING 0.2 TO 10 PSIG; MAXIMUM LINE PRESSURE RATING 100 PSIG; DIFFERENTIAL PRESSURE RATING 0.4 TO 1.5 PSIG; NEMA 1; ZINC PLATED STEEL ENCLOSURE; APPLICATION INDUSTRIAL
$819.75 -
QOM2150MM SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 150 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; BOLT ON MOUNTING; APPROVAL UL; USED ON MP METER-PAK[R] METER CENTER; MP METER-PAK[R] BRAND
$817.18 -
QOM2125MM SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 125 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; BOLT ON MOUNTING; APPROVAL UL; USED ON MP METER-PAK[R] METER CENTER; MP METER-PAK[R] BRAND
$817.18 -
QOM2100MM SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 100 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; BOLT ON MOUNTING; APPROVAL UL; USED ON MP METER-PAK[R] METER CENTER; MP METER-PAK[R] BRAND
$817.18 -
QBP22225TM SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 2 POLE; 240 VAC AT 50/60 HZ (UL/CSA/NOM); 240/415 VAC (IEC); 225 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; BOLT ON MOUNTING; SIZE 3 INCH W X 3.93 INCH D X 6.47 INCH H; APPROVAL UL; CSA; USED ON EZ METER-PAK[R] METER CENTER
$817.18 -
QBP22150TM SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 2 POLE; 240 VAC AT 50/60 HZ (UL/CSA/NOM); 240/415 VAC (IEC); 150 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; BOLT ON MOUNTING; SIZE 3 INCH W X 3.93 INCH D X 6.47 INCH H; APPROVAL UL; CSA; USED ON EZ METER-PAK[R] METER CENTER
$817.18 -
QBP22100TM SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 2 POLE; 240 VAC AT 50/60 HZ (UL/CSA/NOM); 240/415 VAC (IEC); 100 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; BOLT ON MOUNTING; SIZE 3 INCH W X 3.93 INCH D X 6.47 INCH H; APPROVAL UL; CSA; USED ON EZ METER-PAK[R] METER CENTER
$817.18 -
QBM22200TN SQUARE D EXACT REPLACEMENT FOR Q2M2200MT
MOLDED CASE; THERMAL MAGNETIC; Q FRAME; 240 VAC; 200 AMPERE; 2 POLE; INTERRUPTING RATING 10 KILOAMPERE; TERMINAL LINE LUG; SIZE 3 INCH W X 3.93 INCH D X 6.47 INCH H; APPROVAL UL; CSA; CE; POWERPACT[R] BRAND; QB MODEL; APPLICABLE STANDARD W-C-375B/GEN
$817.18 -
8536SCG2V01S SQUARE D/TELEMECANIQUE NEMA NON-COMBINATION STARTERS
FULL VOLTAGE; NON REVERSING; 3 HP AT 115 VAC 50/60 HZ; 5 HP AT 230 VAC 50/60 HZ; 36 AMPERE; 1 PHASE; COIL VOLTAGE 24 V AT 60 HZ; SIZE NEMA 1P; NEMA 1 ENCLOSURE; OVERLOADS MELTING ALLOY; NEMA CONSTRUCTION STANDARD; 8536 MODEL; NUMBER OF POLE 2
$816.41 -
LC1F150U6 SQUARE D/TELEMECANIQUE IEC CONTACTORS
NON REVERSING; 3 POLE; 40 HP AT 200/208 VAC AT 50/60 HZ; 50 HP AT 220/240 VAC AT 50/60 HZ; 100 HP AT 460/480 VAC AT 50/60 HZ; 125 HP AT 575/600 VAC AT 50/60 HZ; INDUCTIVE CURRENT 150 AMPERE (AC-3); RESISTIVE CURRENT 250 AMPERE (AC-1)
$816.41 -
LC1F150L6 SQUARE D/TELEMECANIQUE IEC CONTACTORS
NON REVERSING; 3 POLE; 40 HP AT 200/208 VAC AT 50/60 HZ; 50 HP AT 220/240 VAC AT 50/60 HZ; 100 HP AT 460/480 VAC AT 50/60 HZ; 125 HP AT 575/600 VAC AT 50/60 HZ; INDUCTIVE CURRENT 150 AMPERE (AC-3); RESISTIVE CURRENT 250 AMPERE (AC-1)
$816.41 -
LC1F150G6 SQUARE D/TELEMECANIQUE IEC CONTACTORS
NON REVERSING; 3 POLE; 40 HP AT 200/208 VAC AT 50/60 HZ; 50 HP AT 220/240 VAC AT 50/60 HZ; 100 HP AT 460/480 VAC AT 50/60 HZ; 125 HP AT 575/600 VAC AT 50/60 HZ; INDUCTIVE CURRENT 150 AMPERE (AC-3); RESISTIVE CURRENT 250 AMPERE (AC-1)
$816.41 -
LC1D150L7 SQUARE D/TELEMECANIQUE IEC CONTACTORS
NON REVERSING; 3 POLE; 40 HP AT 200 VAC; 50 HP AT 230 VAC; 100 VAC AT 460 VAC; 125 VAC AT 575 VAC 3 PHASE; INDUCTIVE CURRENT 150 AMPERE (AC-3); RESISTIVE CURRENT 200 AMPERE (AC-1); COIL VOLTAGE 200 VAC AT 50/60 HZ; AUXILIARY CONTACT 1NO-1NC; OPEN
$816.41 -
D224NRB SQUARE D/TELEMECANIQUE FUSIBLE GENERAL DUTY SAFETY SWITCHES
GENERAL DUTY SAFETY; 240 V AC VOLTAGE; 200 AMPERE; POWER RATING 15 HP AT 240 VAC 1 PHASE; 25 HP AT 240 VAC 3 PHASE (STANDARD FOR FAST ACTING ONE TIME FUSE); 60 HP AT 240 VAC 3 PHASE (MAXIMUM FOR DUAL ELEMENT TIME DELAY FUSE); 2 POLE; 3 WIRE
$816.00 -
8736SCO3V02S SQUARE D/TELEMECANIQUE NEMA NON-COMBINATION STARTERS
FULL VOLTAGE; REVERSING; 2 HP AT 115 VAC 50/60 HZ; 3 HP AT 230 VAC 50/60 HZ; 27 AMPERE; 1 PHASE; COIL VOLTAGE 110 V AT 50 HZ; 120 V AT 60 HZ; SIZE NEMA 1; OPEN ENCLOSURE; OVERLOADS MELTING ALLOY THERMAL OVERLOAD RELAY; NEMA CONSTRUCTION STANDARD
$815.54 -
VX5A66D23N4 SQUARE D/TELEMECANIQUE DRIVE ACCESSORIES
POWER BOARD; USED ON ALTIVAR[R] ATV66D23N4 AC DRIVE
$815.24 -
H361EI SQUARE D/TELEMECANIQUE FUSIBLE HEAVY DUTY SAFETY SWITCHES
HEAVY DUTY SAFETY; 480/600 V AC VOLTAGE; 250/600 V DC VOLTAGE; 30 AMPERE; POWER RATING 5 HP AT 480 VAC 3 PHASE; 7 1/2 HP AT 600 VAC 3 PHASE (STANDARD); 15 HP AT 480 VAC 3 PHASE; 20 HP AT 600 VAC 3 PHASE (MAXIMUM); 5 HP AT 250 VDC; 15 HP AT 600 VDC; 3 POLE
$815.15