-
1 × $106.13
-
1 × $7.77
-
1 × $143.82
-
1 × $48.51
-
1 × $100.21
-
1 × $2,726.57
-
1 × $142.11
-
1 × $2,513.81
-
1 × $87.98
-
1 × $161.46
-
1 × $218.99
-
1 × $4,597.22
-
1 × $503.73
-
1 × $32.56
-
1 × $25.29
-
1 × $244.89
-
1 × $487.17
-
1 × $95.23
-
1 × $4,108.29
-
1 × $144.16
-
1 × $665.55
-
1 × $731.00
-
1 × $258.56
-
1 × $195.65
-
1 × $222.63
-
BRH3100 CUTLER-HAMMER CIRCUIT PROTECT DEV STANDARD TRIP PLUG-IN CIRCUIT BREAKERS
THERMAL MAGNETIC; MAIN; 3 POLE; 208 VAC STAR/120 VAC; 240 VAC; 100 AMPERE; INTERRUPTING RATING 22 KILOAMPERE; WIRE SIZE 1 AWG (ALUMINUM/COPPER); APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL
$409.13 -
BRH260 CUTLER-HAMMER CIRCUIT PROTECT DEV STANDARD TRIP PLUG-IN CIRCUIT BREAKERS
THERMAL MAGNETIC; COMMON TRIP; 2 POLE; 120/240 VAC; 60 AMPERE; INTERRUPTING RATING 22 KILOAMPERE; WIRE SIZE 4 TO 1/0 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL
$75.38 -
BRH250 CUTLER-HAMMER CIRCUIT PROTECT DEV STANDARD TRIP PLUG-IN CIRCUIT BREAKERS
THERMAL MAGNETIC; COMMON TRIP; 2 POLE; 120/240 VAC; 50 AMPERE; INTERRUPTING RATING 22 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL
$75.38 -
BRH240 CUTLER-HAMMER CIRCUIT PROTECT DEV STANDARD TRIP PLUG-IN CIRCUIT BREAKERS
THERMAL MAGNETIC; COMMON TRIP; 2 POLE; 120/240 VAC; 40 AMPERE; INTERRUPTING RATING 22 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL
$75.38 -
BRH230 CUTLER-HAMMER CIRCUIT PROTECT DEV STANDARD TRIP PLUG-IN CIRCUIT BREAKERS
THERMAL MAGNETIC; COMMON TRIP; 2 POLE; 120/240 VAC; 30 AMPERE; INTERRUPTING RATING 22 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL
$76.90 -
BRH220 CUTLER-HAMMER CIRCUIT PROTECT DEV STANDARD TRIP PLUG-IN CIRCUIT BREAKERS
THERMAL MAGNETIC; COMMON TRIP; 2 POLE; 120/240 VAC; 20 AMPERE; INTERRUPTING RATING 22 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL
$76.90 -
BRH130 CUTLER-HAMMER CIRCUIT PROTECT DEV STANDARD TRIP PLUG-IN CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120/240 VAC; 30 AMPERE; INTERRUPTING RATING 22 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL
$33.15 -
BRH120 CUTLER-HAMMER CIRCUIT PROTECT DEV STANDARD TRIP PLUG-IN CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120/240 VAC; 20 AMPERE; INTERRUPTING RATING 22 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL
$33.15 -
BRH115 CUTLER-HAMMER CIRCUIT PROTECT DEV STANDARD TRIP PLUG-IN CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120/240 VAC; 15 AMPERE; INTERRUPTING RATING 22 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL
$33.15 -
BRD220230 CUTLER-HAMMER CIRCUIT PROTECT DEV STANDARD TRIP PLUG-IN CIRCUIT BREAKERS
THERMAL MAGNETIC; INDEPENDENT TRIP; QUADPLEX; 2 POLE; 120/240 VAC; 20 AMPERE (OUTSIDE POLE); 30 AMPERE (CENTER POLE; INDEPENDENT TRIP POLE); INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489
$55.89 -
BRCAF120 CUTLER-HAMMER NUMA-LOGIC CTRLS STANDARD TRIP PLUG-IN CIRCUIT BREAKERS
1 POLE; 120/240 VAC; 20 AMPERE; INTERRUPTING RATING 10000 AMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); APPLICATION HACR; WITH ARC FAULT CIRCUIT INTERRUPTER; SIZE 1 INCH W; APPROVAL UL 1699; CSA; USED ON LOAD CENTER; PANEL
$69.44 -
BR390 CUTLER-HAMMER CIRCUIT PROTECT DEV STANDARD TRIP PLUG-IN CIRCUIT BREAKERS
THERMAL MAGNETIC; COMMON TRIP; 3 POLE; 240 VAC; 90 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 4 TO 1/0 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL
$117.21 -
BR380 CUTLER-HAMMER CONTROLS/DISTRIBUTION EQUIPMENT STANDARD TRIP PLUG-IN CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 3 POLE; 240 VAC; 80 AMPERE; INTERRUPTING RATING 10000 AMPERE; LUG TERMINAL; WIRE SIZE 4 TO 1/0 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; USED ON LOAD CENTER; BR MODEL
$117.21 -
BR370 CUTLER-HAMMER CIRCUIT PROTECT DEV STANDARD TRIP PLUG-IN CIRCUIT BREAKERS
THERMAL MAGNETIC; COMMON TRIP; 3 POLE; 240 VAC; 70 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 4 TO 1/0 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL
$113.81 -
BR360 CUTLER-HAMMER CIRCUIT PROTECT DEV STANDARD TRIP PLUG-IN CIRCUIT BREAKERS
THERMAL MAGNETIC; COMMON TRIP; 3 POLE; 240 VAC; 60 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 4 TO 1/0 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL
$76.44 -
BR350 CUTLER-HAMMER CIRCUIT PROTECT DEV STANDARD TRIP PLUG-IN CIRCUIT BREAKERS
THERMAL MAGNETIC; COMMON TRIP; 3 POLE; 240 VAC; 50 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL
$76.44 -
BR340 CUTLER-HAMMER CIRCUIT PROTECT DEV STANDARD TRIP PLUG-IN CIRCUIT BREAKERS
THERMAL MAGNETIC; COMMON TRIP; 3 POLE; 240 VAC; 40 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL
$76.44 -
BR335 CUTLER-HAMMER CIRCUIT PROTECT DEV STANDARD TRIP PLUG-IN CIRCUIT BREAKERS
THERMAL MAGNETIC; COMMON TRIP; 3 POLE; 240 VAC; 35 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL
$76.44 -
BR330 CUTLER-HAMMER CIRCUIT PROTECT DEV STANDARD TRIP PLUG-IN CIRCUIT BREAKERS
THERMAL MAGNETIC; COMMON TRIP; 3 POLE; 240 VAC; 30 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL
$76.44 -
BR325 CUTLER-HAMMER CIRCUIT PROTECT DEV STANDARD TRIP PLUG-IN CIRCUIT BREAKERS
THERMAL MAGNETIC; COMMON TRIP; 3 POLE; 240 VAC; 25 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL
$76.44 -
BR320 CUTLER-HAMMER CIRCUIT PROTECT DEV STANDARD TRIP PLUG-IN CIRCUIT BREAKERS
THERMAL MAGNETIC; COMMON TRIP; 3 POLE; 240 VAC; 20 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL
$76.44 -
BR315 CUTLER-HAMMER CIRCUIT PROTECT DEV STANDARD TRIP PLUG-IN CIRCUIT BREAKERS
THERMAL MAGNETIC; COMMON TRIP; 3 POLE; 240 VAC; 15 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL
$76.44 -
BR3100ST CUTLER-HAMMER CIRCUIT PROTECT DEV STANDARD TRIP PLUG-IN CIRCUIT BREAKERS
THERMAL MAGNETIC; COMMON TRIP; 3 POLE; 240 VAC; 100 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 4 TO 1/0 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL; WITH 120 V SHUNT TRIP
$341.50 -
BR3100 CUTLER-HAMMER CIRCUIT PROTECT DEV STANDARD TRIP PLUG-IN CIRCUIT BREAKERS
THERMAL MAGNETIC; MAIN; 3 POLE; 208 VAC STAR/120 VAC; 240 VAC; 100 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 1 AWG (ALUMINUM/COPPER); APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL
$117.21 -
BR3030 CUTLER-HAMMER CIRCUIT PROTECT DEV STANDARD TRIP PLUG-IN CIRCUIT BREAKERS
THERMAL MAGNETIC; DUPLEX; 3 POLE; 120 VAC; 30 AMPERE (OUTSIDE POLE; INSIDE POLE); INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL
$22.34