1 × $1.95
-
1 × $120.89
-
1 × $408.79
-
1 × $408.79
-
1 × $394.13
-
1 × $14.22
-
1 × $394.13
-
1 × $116.39
-
1 × $141.14
-
1 × $98.49
-
1 × $707.30
-
1 × $125.58
-
1 × $1,945.91
-
1 × $308.09
-
1 × $36.21
-
1 × $227.61
-
1 × $354.47
-
1 × $38.12
-
1 × $99.62
-
1 × $1,388.64
-
1 × $389.94
-
1 × $312.84
-
1 × $5,395.80
-
1 × $391.31
-
1 × $92.08
-
1 × $170.75
-
1 × $622.82
-
1 × $250.96
-
1 × $192.89
-
1 × $148.58
-
1 × $120.89
-
1 × $140.68
-
1 × $2.51
-
1 × $16.79
-
1 × $475.20
-
1 × $1,300.62
-
1 × $379.39
-
1 × $35.19
-
1 × $7.73
-
1 × $127.42
-
1 × $52.02
-
1 × $1,316.43
-
1 × $1.76
-
1 × $515.55
-
1 × $506.99
-
1 × $129.65
-
1 × $120.89
-
1 × $2,560.49
-
1 × $9.69
-
1 × $395.30
-
1 × $815.89
-
1 × $1.96
-
1 × $323.15
-
1 × $202.96
-
1 × $193.43
-
1 × $13.57
-
1 × $179.19
-
1 × $11.24
-
1 × $35.53
-
1 × $82.59
-
1 × $2.25
-
1 × $120.89
-
1 × $41.44
-
1 × $19.81
-
1 × $44.72
-
1 × $58.58
-
1 × $45.08
-
BQD335 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ (UL); 35 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC (UL); TERMINAL LOAD LUG; SIZE 3 INCH W X 4.49 INCH H
$232.36 -
BQD330 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ (UL); 30 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC (UL); TERMINAL LOAD LUG; SIZE 3 INCH W X 4.49 INCH H
$232.36 -
BQD325 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ (UL); 25 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC (UL); TERMINAL LOAD LUG; SIZE 3 INCH W X 4.49 INCH H
$232.36 -
BQD320 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ (UL); 20 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC (UL); TERMINAL LOAD LUG; SIZE 3 INCH W X 4.49 INCH H
$232.36 -
BQD315 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ (UL); 15 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC (UL); TERMINAL LOAD LUG; SIZE 3 INCH W X 4.49 INCH H
$232.36 -
BQD3100 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ (UL); 100 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC (UL); TERMINAL LOAD LUG; SIZE 3 INCH W X 4.49 INCH H
$305.20 -
BQD290 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 90 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$271.24 -
BQD280 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 80 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$271.24 -
BQD270 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 70 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$271.24 -
BQD260 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 60 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$138.15 -
BQD250 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 50 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$138.15 -
BQD245 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 45 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$138.15 -
BQD240 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 40 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$138.15 -
BQD235 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 35 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$138.15 -
BQD230 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 30 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$138.15 -
BQD225 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 25 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$138.15 -
BQD220 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 20 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$138.15 -
BQD215 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 15 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$138.15 -
BQD2100 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 100 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$271.24 -
BQD160 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 120/277 VAC AT 60 HZ; 125 VDC (UL); 60 AMPERE AT 40 DEG C; 1 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 120 VAC; 14 KILOAMPERE AT 277 VAC/125 VDC (UL); TERMINAL LOAD LUG; SIZE 1 INCH W X 4.49 INCH H
$68.88 -
BQD150 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 120/277 VAC AT 60 HZ; 125 VDC (UL); 50 AMPERE AT 40 DEG C; 1 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 120 VAC; 14 KILOAMPERE AT 277 VAC/125 VDC (UL); TERMINAL LOAD LUG; SIZE 1 INCH W X 4.49 INCH H
$68.88 -
BQD140 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 120/277 VAC AT 60 HZ; 125 VDC (UL); 40 AMPERE AT 40 DEG C; 1 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 120 VAC; 14 KILOAMPERE AT 277 VAC/125 VDC (UL); TERMINAL LOAD LUG; SIZE 1 INCH W X 4.49 INCH H
$68.88 -
BQD120 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 120/277 VAC AT 60 HZ; 125 VDC (UL); 20 AMPERE AT 40 DEG C; 1 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 120 VAC; 14 KILOAMPERE AT 277 VAC/125 VDC (UL); TERMINAL LOAD LUG; SIZE 1 INCH W X 4.49 INCH H
$68.88 -
BQD115 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 120/277 VAC AT 60 HZ; 125 VDC (UL); 15 AMPERE AT 40 DEG C; 1 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 120 VAC; 14 KILOAMPERE AT 277 VAC/125 VDC (UL); TERMINAL LOAD LUG; SIZE 1 INCH W X 4.49 INCH H
$68.88 -
BQC220220 CUTLER-HAMMER CIRCUIT PROTECT DEV STANDARD TRIP PLUG-IN CIRCUIT BREAKERS
THERMAL MAGNETIC; COMMON TRIP; QUADPLEX; 2 POLE; 120/240 VAC; 20 AMPERE (OUTSIDE POLE; CENTER POLE; COMMON TRIP POLE); INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); APPROVAL UL 489; USED ON LOAD CENTER; BQC MODEL
$39.66