1 × $70.03
-
1 × $16,997.95
-
1 × $0.48
-
1 × $9.49
-
1 × $1.98
-
1 × $41.05
-
1 × $1,682.22
-
1 × $323.15
-
1 × $0.69
-
1 × $0.89
-
1 × $0.89
-
1 × $35.53
-
1 × $58.00
-
1 × $99.62
-
1 × $148.94
-
1 × $2.08
-
1 × $4.33
-
1 × $1,114.07
-
1 × $53,852.43
-
1 × $539.10
-
1 × $99.62
-
1 × $136.76
-
1 × $92.08
-
1 × $0.89
-
1 × $2.63
-
1 × $17,038.89
-
1 × $1,088.36
-
1 × $0.89
-
1 × $3.63
-
1 × $9.95
-
1 × $4,816.34
-
1 × $102.31
-
1 × $69.69
-
1 × $6,988.93
-
1 × $6.78
-
1 × $940.53
-
1 × $6,601.36
-
1 × $1.66
-
1 × $18.65
-
1 × $2,167.92
-
1 × $82.11
-
1 × $0.89
-
1 × $3.47
-
1 × $1,075.64
-
1 × $626.15
-
1 × $1.87
-
1 × $0.59
-
1 × $4,665.41
-
1 × $5,991.17
-
1 × $45.59
-
1 × $6,232.00
-
1 × $6.27
-
1 × $8.74
-
1 × $3.72
-
1 × $0.89
-
BQD335 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ (UL); 35 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC (UL); TERMINAL LOAD LUG; SIZE 3 INCH W X 4.49 INCH H
$232.36 -
BQD330 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ (UL); 30 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC (UL); TERMINAL LOAD LUG; SIZE 3 INCH W X 4.49 INCH H
$232.36 -
BQD325 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ (UL); 25 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC (UL); TERMINAL LOAD LUG; SIZE 3 INCH W X 4.49 INCH H
$232.36 -
BQD320 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ (UL); 20 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC (UL); TERMINAL LOAD LUG; SIZE 3 INCH W X 4.49 INCH H
$232.36 -
BQD315 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ (UL); 15 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC (UL); TERMINAL LOAD LUG; SIZE 3 INCH W X 4.49 INCH H
$232.36 -
BQD3100 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ (UL); 100 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC (UL); TERMINAL LOAD LUG; SIZE 3 INCH W X 4.49 INCH H
$305.20 -
BQD290 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 90 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$271.24 -
BQD280 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 80 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$271.24 -
BQD270 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 70 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$271.24 -
BQD260 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 60 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$138.15 -
BQD250 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 50 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$138.15 -
BQD245 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 45 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$138.15 -
BQD240 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 40 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$138.15 -
BQD235 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 35 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$138.15 -
BQD230 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 30 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$138.15 -
BQD225 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 25 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$138.15 -
BQD220 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 20 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$138.15 -
BQD215 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 15 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$138.15 -
BQD2100 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 100 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$271.24 -
BQD160 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 120/277 VAC AT 60 HZ; 125 VDC (UL); 60 AMPERE AT 40 DEG C; 1 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 120 VAC; 14 KILOAMPERE AT 277 VAC/125 VDC (UL); TERMINAL LOAD LUG; SIZE 1 INCH W X 4.49 INCH H
$68.88 -
BQD150 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 120/277 VAC AT 60 HZ; 125 VDC (UL); 50 AMPERE AT 40 DEG C; 1 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 120 VAC; 14 KILOAMPERE AT 277 VAC/125 VDC (UL); TERMINAL LOAD LUG; SIZE 1 INCH W X 4.49 INCH H
$68.88 -
BQD140 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 120/277 VAC AT 60 HZ; 125 VDC (UL); 40 AMPERE AT 40 DEG C; 1 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 120 VAC; 14 KILOAMPERE AT 277 VAC/125 VDC (UL); TERMINAL LOAD LUG; SIZE 1 INCH W X 4.49 INCH H
$68.88 -
BQD120 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 120/277 VAC AT 60 HZ; 125 VDC (UL); 20 AMPERE AT 40 DEG C; 1 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 120 VAC; 14 KILOAMPERE AT 277 VAC/125 VDC (UL); TERMINAL LOAD LUG; SIZE 1 INCH W X 4.49 INCH H
$68.88 -
BQD115 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 120/277 VAC AT 60 HZ; 125 VDC (UL); 15 AMPERE AT 40 DEG C; 1 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 120 VAC; 14 KILOAMPERE AT 277 VAC/125 VDC (UL); TERMINAL LOAD LUG; SIZE 1 INCH W X 4.49 INCH H
$68.88 -
BQC220220 CUTLER-HAMMER CIRCUIT PROTECT DEV STANDARD TRIP PLUG-IN CIRCUIT BREAKERS
THERMAL MAGNETIC; COMMON TRIP; QUADPLEX; 2 POLE; 120/240 VAC; 20 AMPERE (OUTSIDE POLE; CENTER POLE; COMMON TRIP POLE); INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); APPROVAL UL 489; USED ON LOAD CENTER; BQC MODEL
$39.66