-
1 × $1,019.58
-
1 × $157.75
-
1 × $16.38
-
1 × $182.84
-
1 × $12.47
-
1 × $127.79
-
1 × $458.61
-
2 × $34.10
-
1 × $67.93
-
1 × $228.80
-
1 × $179.47
-
1 × $309.97
-
1 × $126.42
-
1 × $170.44
-
1 × $230.28
-
1 × $200.96
-
1 × $11.16
-
1 × $344.14
-
1 × $136.76
-
1 × $319.06
-
1 × $200.22
-
1 × $170.75
-
1 × $180.29
-
1 × $114.30
-
1 × $834.89
-
1 × $159.00
-
1 × $389.29
-
1 × $11.24
-
1 × $66.19
-
1 × $303.54
-
1 × $206.83
-
1 × $304.78
-
1 × $148.09
-
1 × $2.75
-
1 × $185.06
-
1 × $170.44
-
1 × $879.28
-
1 × $206.83
-
1 × $2.83
-
1 × $204.34
-
1 × $25.73
-
1 × $0.89
-
1 × $3,505.40
-
1 × $3.47
-
1 × $260.00
-
1 × $11.03
-
1 × $227.40
-
1 × $192.75
-
1 × $162.50
-
1 × $3.41
-
1 × $261.71
-
1 × $143.82
-
BQD335 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ (UL); 35 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC (UL); TERMINAL LOAD LUG; SIZE 3 INCH W X 4.49 INCH H
$232.36 -
BQD330 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ (UL); 30 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC (UL); TERMINAL LOAD LUG; SIZE 3 INCH W X 4.49 INCH H
$232.36 -
BQD325 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ (UL); 25 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC (UL); TERMINAL LOAD LUG; SIZE 3 INCH W X 4.49 INCH H
$232.36 -
BQD320 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ (UL); 20 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC (UL); TERMINAL LOAD LUG; SIZE 3 INCH W X 4.49 INCH H
$232.36 -
BQD315 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ (UL); 15 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC (UL); TERMINAL LOAD LUG; SIZE 3 INCH W X 4.49 INCH H
$232.36 -
BQD3100 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ (UL); 100 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC (UL); TERMINAL LOAD LUG; SIZE 3 INCH W X 4.49 INCH H
$305.20 -
BQD290 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 90 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$271.24 -
BQD280 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 80 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$271.24 -
BQD270 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 70 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$271.24 -
BQD260 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 60 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$138.15 -
BQD250 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 50 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$138.15 -
BQD245 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 45 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$138.15 -
BQD240 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 40 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$138.15 -
BQD235 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 35 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$138.15 -
BQD230 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 30 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$138.15 -
BQD225 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 25 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$138.15 -
BQD220 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 20 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$138.15 -
BQD215 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 15 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$138.15 -
BQD2100 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 100 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$271.24 -
BQD160 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 120/277 VAC AT 60 HZ; 125 VDC (UL); 60 AMPERE AT 40 DEG C; 1 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 120 VAC; 14 KILOAMPERE AT 277 VAC/125 VDC (UL); TERMINAL LOAD LUG; SIZE 1 INCH W X 4.49 INCH H
$68.88 -
BQD150 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 120/277 VAC AT 60 HZ; 125 VDC (UL); 50 AMPERE AT 40 DEG C; 1 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 120 VAC; 14 KILOAMPERE AT 277 VAC/125 VDC (UL); TERMINAL LOAD LUG; SIZE 1 INCH W X 4.49 INCH H
$68.88 -
BQD140 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 120/277 VAC AT 60 HZ; 125 VDC (UL); 40 AMPERE AT 40 DEG C; 1 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 120 VAC; 14 KILOAMPERE AT 277 VAC/125 VDC (UL); TERMINAL LOAD LUG; SIZE 1 INCH W X 4.49 INCH H
$68.88 -
BQD120 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 120/277 VAC AT 60 HZ; 125 VDC (UL); 20 AMPERE AT 40 DEG C; 1 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 120 VAC; 14 KILOAMPERE AT 277 VAC/125 VDC (UL); TERMINAL LOAD LUG; SIZE 1 INCH W X 4.49 INCH H
$68.88 -
BQD115 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 120/277 VAC AT 60 HZ; 125 VDC (UL); 15 AMPERE AT 40 DEG C; 1 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 120 VAC; 14 KILOAMPERE AT 277 VAC/125 VDC (UL); TERMINAL LOAD LUG; SIZE 1 INCH W X 4.49 INCH H
$68.88 -
BQC220220 CUTLER-HAMMER CIRCUIT PROTECT DEV STANDARD TRIP PLUG-IN CIRCUIT BREAKERS
THERMAL MAGNETIC; COMMON TRIP; QUADPLEX; 2 POLE; 120/240 VAC; 20 AMPERE (OUTSIDE POLE; CENTER POLE; COMMON TRIP POLE); INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); APPROVAL UL 489; USED ON LOAD CENTER; BQC MODEL
$39.66