-
1 × $250.96
-
1 × $176.45
-
1 × $215.58
-
1 × $1,177.32
-
1 × $121.99
-
1 × $1,401.90
-
1 × $45.32
-
1 × $3,167.10
-
1 × $82.59
-
1 × $4.70
-
1 × $5.85
-
1 × $2,038.57
-
1 × $941.72
-
1 × $6.89
-
1 × $612.96
-
1 × $6.89
-
1 × $102.31
-
1 × $8.74
-
1 × $2.25
-
1 × $225.18
-
1 × $18.00
-
1 × $152.89
-
1 × $14.61
-
1 × $100.21
-
1 × $1.95
-
1 × $140.68
-
1 × $637.99
-
1 × $13.90
-
1 × $117.49
-
1 × $1,844.64
-
1 × $218.14
-
1 × $690.05
-
1 × $222.11
-
1 × $512.74
-
1 × $61.91
-
1 × $159.52
-
1 × $7.19
-
1 × $429.51
-
1 × $96.60
-
1 × $141.52
-
1 × $876.78
-
1 × $457.94
-
1 × $6.17
-
1 × $994.10
-
1 × $4.51
-
1 × $1,433.25
-
1 × $137.53
-
1 × $11.04
-
1 × $152.89
-
1 × $134.93
-
1 × $1,913.46
-
1 × $152.89
-
1 × $272.17
-
1 × $3.03
-
1 × $391.34
-
1 × $252.74
-
1 × $306.03
-
1 × $1,380.10
-
1 × $127.76
-
1 × $699.99
-
1 × $331.87
-
1 × $304.78
-
1 × $35.06
-
QC3015H CUTLER-HAMMER MULTIPLE METERING DIN RAIL MOUNT CIRCUIT BREAKERS
THERMAL MAGNETIC; 3 POLE; 240 VAC; 15 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; RING TERMINAL; WIRE SIZE 14 TO 10 AWG (ALUMINUM/COPPER; LINE); CABLE IN; CABLE OUT MOUNTING; APPROVAL UL 489; CSA; QUICKLAG[R] BRAND; QC MODEL
$176.53 -
QC2100 CUTLER-HAMMER MULTIPLE METERING DIN RAIL MOUNT CIRCUIT BREAKERS
THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 100 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 5000 AMPERE AT 24 TO 48/62.5/80 VDC; BOX LUG TERMINAL; WIRE SIZE 14 TO 10 AWG ALUMINUM/COPPER (LINE); 8 TO 1/0 AWG ALUMINUM/COPPER (LOAD)
$140.56 -
QC2090 CUTLER-HAMMER MULTIPLE METERING DIN RAIL MOUNT CIRCUIT BREAKERS
THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 90 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 5000 AMPERE AT 24 TO 48/62.5/80 VDC; BOX LUG TERMINAL; WIRE SIZE 14 TO 10 AWG ALUMINUM/COPPER (LINE); 8 TO 1/0 AWG ALUMINUM/COPPER (LOAD)
$140.56 -
QC2080 CUTLER-HAMMER MULTIPLE METERING DIN RAIL MOUNT CIRCUIT BREAKERS
THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 80 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 5000 AMPERE AT 24 TO 48/62.5/80 VDC; BOX LUG TERMINAL; WIRE SIZE 14 TO 10 AWG ALUMINUM/COPPER (LINE); 8 TO 1/0 AWG ALUMINUM/COPPER (LOAD)
$140.56 -
QC2070 CUTLER HAMMER WESTINGHOUSE FEED THROUGH
THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 70 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 5000 AMPERE AT 24 TO 48/62.5/80 VDC; BOX LUG TERMINAL; WIRE SIZE 14 TO 10 AWG ALUMINUM/COPPER (LINE); 8 TO 1/0 AWG ALUMINUM/COPPER (LOAD)
$112.69 -
QC2060 CUTLER-HAMMER MULTIPLE METERING DIN RAIL MOUNT CIRCUIT BREAKERS
THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 60 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 5000 AMPERE AT 24 TO 48/62.5/80 VDC; BOX LUG TERMINAL; WIRE SIZE 14 TO 10 AWG ALUMINUM/COPPER (LINE); 14 TO 4 AWG ALUMINUM/COPPER (LOAD)
$56.41 -
QC2050 CUTLER-HAMMER MULTIPLE METERING DIN RAIL MOUNT CIRCUIT BREAKERS
THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 50 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 5000 AMPERE AT 24 TO 48/62.5/80 VDC; BOX LUG TERMINAL; WIRE SIZE 14 TO 10 AWG ALUMINUM/COPPER (LINE); 14 TO 4 AWG ALUMINUM/COPPER (LOAD)
$56.41 -
QC2045 CUTLER-HAMMER MULTIPLE METERING SUPPLEMENTARY PROTECTOR CIRCUIT BREAKERS
THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 45 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; ALUMINUM BOX LUG LINE TERMINAL; STEEL BOX LUG LOAD TERMINAL TERMINAL; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER; LOAD); CABLE IN; CABLE OUT MOUNTING; APPROVAL UL 489; CSA
$57.17 -
QC2040 CUTLER-HAMMER MULTIPLE METERING DIN RAIL MOUNT CIRCUIT BREAKERS
THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 40 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 5000 AMPERE AT 24 TO 48/62.5/80 VDC; BOX LUG TERMINAL; WIRE SIZE 14 TO 10 AWG ALUMINUM/COPPER (LINE); 14 TO 4 AWG ALUMINUM/COPPER (LOAD)
$56.41 -
QC2030H CUTLER-HAMMER MULTIPLE METERING DIN RAIL MOUNT CIRCUIT BREAKERS
THERMAL MAGNETIC; 2 POLE; 240 VAC; 30 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE; BOX LUG TERMINAL; WIRE SIZE 14 TO 10 AWG ALUMINUM/COPPER (LINE); 14 TO 4 AWG ALUMINUM/COPPER (LOAD); CABLE IN; CABLE OUT MOUNTING; APPROVAL UL 489; CSA
$332.03 -
QC2030 CUTLER HAMMER WESTINGHOUSE FEED THROUGH
THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 30 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 5000 AMPERE AT 24 TO 48/62.5/80 VDC; BOX LUG TERMINAL; WIRE SIZE 14 TO 10 AWG ALUMINUM/COPPER (LINE); 14 TO 4 AWG ALUMINUM/COPPER (LOAD)
$56.41 -
QC2025 CUTLER-HAMMER MULTIPLE METERING DIN RAIL MOUNT CIRCUIT BREAKERS
THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 25 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 5000 AMPERE AT 24 TO 48/62.5/80 VDC; BOX LUG TERMINAL; WIRE SIZE 14 TO 10 AWG ALUMINUM/COPPER (LINE); 14 TO 4 AWG ALUMINUM/COPPER (LOAD)
$56.41 -
QC2020 CUTLER-HAMMER MULTIPLE METERING DIN RAIL MOUNT CIRCUIT BREAKERS
THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 20 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 5000 AMPERE AT 24 TO 48/62.5/80 VDC; RING TERMINAL; WIRE SIZE 14 TO 10 AWG (ALUMINUM/COPPER; LINE); CABLE IN; CABLE OUT MOUNTING
$56.41 -
QC2010 CUTLER-HAMMER MULTIPLE METERING DIN RAIL MOUNT CIRCUIT BREAKERS
THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 10 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 5000 AMPERE AT 24 TO 48/62.5/80 VDC; RING TERMINAL; WIRE SIZE 14 TO 10 AWG (ALUMINUM/COPPER; LINE); CABLE IN; CABLE OUT MOUNTING; APPROVAL CSA
$56.41 -
QC1FP CUTLER-HAMMER MULTIPLE METERING CIRCUIT BREAKER ACCESSORIES
1 POLE; USED ON QUICKLAG[R] TYPE C MINIATURE CIRCUIT BREAKER; QC MODEL
$22.98 -
QC1070 CUTLER-HAMMER MULTIPLE METERING DIN RAIL MOUNT CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120/240 VAC; 70 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 5000 AMPERE AT 24 TO 48 VDC; 2500 AMPERE AT 62.5 VDC; BOX LUG TERMINAL; WIRE SIZE 14 TO 10 AWG ALUMINUM/COPPER (LINE)
$118.40 -
QC1060 CUTLER-HAMMER MULTIPLE METERING DIN RAIL MOUNT CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120/240 VAC; 60 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 5000 AMPERE AT 24 TO 48 VDC; 2500 AMPERE AT 62.5 VDC; BOX LUG TERMINAL; WIRE SIZE 14 TO 10 AWG ALUMINUM/COPPER (LINE)
$26.77 -
QC1040 CUTLER-HAMMER MULTIPLE METERING DIN RAIL MOUNT CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120/240 VAC; 40 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 5000 AMPERE AT 24 TO 48 VDC; 3800 AMPERE AT 62.5 VDC; BOX LUG TERMINAL; WIRE SIZE 14 TO 10 AWG ALUMINUM/COPPER (LINE)
$23.42 -
QC1030 CUTLER-HAMMER MULTIPLE METERING DIN RAIL MOUNT CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120/240 VAC; 30 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 5000 AMPERE AT 24 TO 48 VDC; 3800 AMPERE AT 62.5 VDC; BOX LUG TERMINAL; WIRE SIZE 14 TO 10 AWG ALUMINUM/COPPER (LINE)
$23.42 -
QC1020 CUTLER-HAMMER MULTIPLE METERING DIN RAIL MOUNT CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120/240 VAC; 20 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 5000 AMPERE AT 24 TO 48 VDC; 3800 AMPERE AT 62.5 VDC; RING TERMINAL; WIRE SIZE 14 TO 10 AWG (ALUMINUM/COPPER; LINE)
$23.42 -
QC1015 CUTLER-HAMMER MULTIPLE METERING DIN RAIL MOUNT CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120/240 VAC; 15 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 5000 AMPERE AT 24 TO 48 VDC; 3800 AMPERE AT 62.5 VDC; RING TERMINAL; WIRE SIZE 14 TO 10 AWG (ALUMINUM/COPPER; LINE)
$23.42 -
QC1010 CUTLER-HAMMER MULTIPLE METERING DIN RAIL MOUNT CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120/240 VAC; 10 AMPERE AT 40 DEG C; INTERRUPTING RATING 10000 AMPERE AT 120/240 VAC; 5000 AMPERE AT 24 TO 48 VDC; 3800 AMPERE AT 62.5 VDC; RING TERMINAL; WIRE SIZE 14 TO 10 AWG (ALUMINUM/COPPER; LINE)
$26.77 -
QBHW3090H CUTLER-HAMMER MULTIPLE METERING STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 3 POLE; 240 VAC; 90 AMPERE AT 40 DEG C; INTERRUPTING RATING 22000 AMPERE; EXTENDED TANG LINE TERMINAL; BOX LUG LOAD TERMINAL TERMINAL; WIRE SIZE 8 TO 1/0 AWG (ALUMINUM/COPPER; LOAD); BOLT ON MOUNTING; APPROVAL UL 489; CSA
$344.20 -
QBHW3080H CUTLER-HAMMER MULTIPLE METERING STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 3 POLE; 240 VAC; 80 AMPERE AT 40 DEG C; INTERRUPTING RATING 22000 AMPERE; EXTENDED TANG LINE TERMINAL; BOX LUG LOAD TERMINAL TERMINAL; WIRE SIZE 8 TO 1/0 AWG (ALUMINUM/COPPER; LOAD); BOLT ON MOUNTING; APPROVAL UL 489; CSA
$344.20 -
QBHW3070H CUTLER-HAMMER MULTIPLE METERING STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 3 POLE; 240 VAC; 70 AMPERE AT 40 DEG C; INTERRUPTING RATING 22000 AMPERE; EXTENDED TANG LINE TERMINAL; BOX LUG LOAD TERMINAL TERMINAL; WIRE SIZE 8 TO 1/0 AWG (ALUMINUM/COPPER; LOAD); BOLT ON MOUNTING; APPROVAL UL 489; CSA
$344.20