-
1 × $7,069.28
-
1 × $170.44
-
1 × $326.57
-
1 × $4,507.96
-
1 × $225.15
-
1 × $7,381.41
-
1 × $1,480.74
-
1 × $349.29
-
1 × $5,278.50
-
1 × $539.95
-
1 × $200.96
-
1 × $57.81
-
1 × $58.00
-
1 × $291.60
-
1 × $165.25
-
1 × $40.12
-
1 × $59.02
-
1 × $4,999.33
-
1 × $5,991.17
-
1 × $5,060.46
-
1 × $411.84
-
1 × $89.38
-
1 × $1,090.89
-
1 × $5,909.44
-
1 × $5,909.44
-
1 × $5,826.62
-
1 × $538.56
-
1 × $190.08
-
CED63B040 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
FUSELESS CURRENT LIMITING; THERMAL MAGNETIC; 3 POLE; 600 VAC; 500 VDC; 40 AMPERE AT 40 DEG C; INTERRUPTING RATING 200 KILOAMPERE AT 240/480 VAC; 100 KILOAMPERE AT 600 VAC; 50 KILOAMPERE AT 500 VDC (UL); LUG LOAD TERMINAL TERMINAL
$1,071.43 -
CED63B015 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
FUSELESS CURRENT LIMITING; THERMAL MAGNETIC; 3 POLE; 600 VAC; 500 VDC; 15 AMPERE AT 40 DEG C; INTERRUPTING RATING 200 KILOAMPERE AT 240/480 VAC; 100 KILOAMPERE AT 600 VAC; 50 KILOAMPERE AT 500 VDC (UL); LUG LOAD TERMINAL TERMINAL
$1,071.43 -
CC94.0 SQUARE D/TELEMECANIQUE THERMAL OVERLOAD HEATER ELEMENTS
CLASS 20; STANDARD TRIP; MOTOR FLA 132 TO 142 AMPERE (1 THERMAL UNIT); PLUG IN MOUNTING; USED ON AC MAGNETIC STARTER; SQUARE D[R] BRAND
$26.37 -
CC87.7 SQUARE D/TELEMECANIQUE THERMAL OVERLOAD HEATER ELEMENTS
CLASS 20; STANDARD TRIP; MOTOR FLA 123 TO 131 AMPERE (1 THERMAL UNIT); PLUG IN MOUNTING; USED ON AC MAGNETIC STARTER; SQUARE D[R] BRAND
$26.37 -
CC81.5 SQUARE D HEATER ELEMENTS
CLASS 20; STANDARD TRIP; MOTOR FLA 113 TO 122 AMPERE (1 THERMAL UNIT); PLUG IN MOUNTING; USED ON AC MAGNETIC STARTER; SQUARE D[R] BRAND
$26.37 -
CC74.6 SQUARE D/TELEMECANIQUE THERMAL OVERLOAD HEATER ELEMENTS
CLASS 20; STANDARD TRIP; MOTOR FLA 105 TO 112 AMPERE (1 THERMAL UNIT); PLUG IN MOUNTING; USED ON AC MAGNETIC STARTER; SQUARE D[R] BRAND
$26.37 -
CC64.3 SQUARE D/TELEMECANIQUE THERMAL OVERLOAD HEATER ELEMENTS
CLASS 20; STANDARD TRIP; MOTOR FLA 51.4 TO 54.6 AMPERE (1 THERMAL UNIT); PLUG IN MOUNTING; USED ON AC MAGNETIC STARTER; SQUARE D[R] BRAND
$26.37 -
CC54.5 SQUARE D/TELEMECANIQUE THERMAL OVERLOAD HEATER ELEMENTS
CLASS 20; STANDARD TRIP; MOTOR FLA 68.2 TO 73.7 AMPERE (1 THERMAL UNIT); PLUG IN MOUNTING; USED ON AC MAGNETIC STARTER; SQUARE D[R] BRAND
$26.37 -
CC50.1 SQUARE D/TELEMECANIQUE THERMAL OVERLOAD HEATER ELEMENTS
CLASS 20; STANDARD TRIP; MOTOR FLA 63.4 TO 68.1 AMPERE (1 THERMAL UNIT); PLUG IN MOUNTING; USED ON AC MAGNETIC STARTER; SQUARE D[R] BRAND
$26.37 -
CC46.6 SQUARE D/TELEMECANIQUE THERMAL OVERLOAD HEATER ELEMENTS
CLASS 20; STANDARD TRIP; MOTOR FLA 59 TO 63.3 AMPERE (1 THERMAL UNIT); PLUG IN MOUNTING; USED ON AC MAGNETIC STARTER; SQUARE D[R] BRAND
$26.37 -
CC39.6 SQUARE D/TELEMECANIQUE THERMAL OVERLOAD HEATER ELEMENTS
CLASS 20; STANDARD TRIP; MOTOR FLA 50.6 TO 54.3 AMPERE (1 THERMAL UNIT); PLUG IN MOUNTING; USED ON AC MAGNETIC STARTER; SQUARE D[R] BRAND
$26.37 -
CC36.4 SQUARE D/TELEMECANIQUE THERMAL OVERLOAD HEATER ELEMENTS
CLASS 20; STANDARD TRIP; MOTOR FLA 46.8 TO 50.5 AMPERE (1 THERMAL UNIT); PLUG IN MOUNTING; USED ON AC MAGNETIC STARTER; SQUARE D[R] BRAND
$26.37 -
CC33.3 SQUARE D/TELEMECANIQUE THERMAL OVERLOAD HEATER ELEMENTS
CLASS 20; STANDARD TRIP; MOTOR FLA 43.6 TO 46.7 AMPERE (1 THERMAL UNIT); PLUG IN MOUNTING; USED ON AC MAGNETIC STARTER; SQUARE D[R] BRAND
$42.67 -
CC31.0 SQUARE D/TELEMECANIQUE THERMAL OVERLOAD HEATER ELEMENTS
CLASS 20; STANDARD TRIP; MOTOR FLA 40.6 TO 43.5 AMPERE (1 THERMAL UNIT); PLUG IN MOUNTING; USED ON AC MAGNETIC STARTER; SQUARE D[R] BRAND
$42.67 -
CC28.8 SQUARE D/TELEMECANIQUE THERMAL OVERLOAD HEATER ELEMENTS
CLASS 20; STANDARD TRIP; MOTOR FLA 37.6 TO 40.5 AMPERE (1 THERMAL UNIT); PLUG IN MOUNTING; USED ON AC MAGNETIC STARTER; SQUARE D[R] BRAND
$42.67 -
CC26.3 SQUARE D/TELEMECANIQUE THERMAL OVERLOAD HEATER ELEMENTS
CLASS 20; STANDARD TRIP; MOTOR FLA 34.6 TO 37.5 AMPERE (1 THERMAL UNIT); PLUG IN MOUNTING; USED ON AC MAGNETIC STARTER; SQUARE D[R] BRAND
$26.37 -
CC24.6 SQUARE D/TELEMECANIQUE THERMAL OVERLOAD HEATER ELEMENTS
CLASS 20; STANDARD TRIP; MOTOR FLA 32.6 TO 34.5 AMPERE (1 THERMAL UNIT); PLUG IN MOUNTING; USED ON AC MAGNETIC STARTER; SQUARE D[R] BRAND
$42.67 -
CC22.8 SQUARE D/TELEMECANIQUE THERMAL OVERLOAD HEATER ELEMENTS
CLASS 20; STANDARD TRIP; MOTOR FLA 30 TO 32.5 AMPERE (1 THERMAL UNIT); PLUG IN MOUNTING; USED ON AC MAGNETIC STARTER; SQUARE D[R] BRAND
$42.67 -
CC219.0 SQUARE D/TELEMECANIQUE THERMAL OVERLOAD HEATER ELEMENTS
CLASS 20; STANDARD TRIP; MOTOR FLA 142 TO 150 AMPERE (1 THERMAL UNIT); PLUG IN MOUNTING; USED ON AC MAGNETIC STARTER; SQUARE D[R] BRAND
$26.37 -
CC208.0 SQUARE D/TELEMECANIQUE THERMAL OVERLOAD HEATER ELEMENTS
CLASS 20; STANDARD TRIP; MOTOR FLA 132 TO 141 AMPERE (1 THERMAL UNIT); PLUG IN MOUNTING; USED ON AC MAGNETIC STARTER; SQUARE D[R] BRAND
$26.37 -
CC20.9 SQUARE D/TELEMECANIQUE THERMAL OVERLOAD HEATER ELEMENTS
CLASS 20; STANDARD TRIP; MOTOR FLA 28 TO 29.9 AMPERE (1 THERMAL UNIT); PLUG IN MOUNTING; USED ON AC MAGNETIC STARTER; SQUARE D[R] BRAND
$26.37 -
CC196.0 SQUARE D/TELEMECANIQUE THERMAL OVERLOAD HEATER ELEMENTS
CLASS 20; STANDARD TRIP; MOTOR FLA 248 TO 266 AMPERE (1 THERMAL UNIT); PLUG IN MOUNTING; USED ON AC MAGNETIC STARTER; SQUARE D[R] BRAND
$26.37 -
CC167.0 SQUARE D/TELEMECANIQUE THERMAL OVERLOAD HEATER ELEMENTS
CLASS 20; STANDARD TRIP; MOTOR FLA 210 TO 227 AMPERE (1 THERMAL UNIT); PLUG IN MOUNTING; USED ON AC MAGNETIC STARTER; SQUARE D[R] BRAND
$26.37 -
CC156.0 SQUARE D/TELEMECANIQUE THERMAL OVERLOAD HEATER ELEMENTS
CLASS 20; STANDARD TRIP; MOTOR FLA 196 TO 209 AMPERE (1 THERMAL UNIT); PLUG IN MOUNTING; USED ON AC MAGNETIC STARTER; SQUARE D[R] BRAND
$26.37 -
CC143.0 SQUARE D/TELEMECANIQUE THERMAL OVERLOAD HEATER ELEMENTS
CLASS 20; STANDARD TRIP; MOTOR FLA 182 TO 195 AMPERE (1 THERMAL UNIT); PLUG IN MOUNTING; USED ON AC MAGNETIC STARTER; SQUARE D[R] BRAND
$26.37