-
1 × $209.31
-
1 × $62.82
-
1 × $98.49
-
1 × $485.30
-
1 × $174.02
-
1 × $487.17
-
1 × $1.05
-
1 × $142.89
-
1 × $1.95
-
1 × $3.52
-
1 × $646.25
-
1 × $209.79
-
1 × $1,667.29
-
1 × $108.36
-
1 × $781.72
-
1 × $126.04
-
1 × $1,112.77
-
1 × $374.99
-
1 × $268.47
-
1 × $0.74
-
1 × $209.79
-
1 × $1,396.65
-
1 × $539.95
-
1 × $2.12
-
1 × $21.25
-
1 × $781.72
-
1 × $19.16
-
1 × $607.00
-
1 × $1,162.13
-
1 × $1.01
-
1 × $126.36
-
1 × $268.47
-
1 × $12.72
-
1 × $273.03
-
1 × $3.11
-
1 × $1.01
-
1 × $19.38
-
1 × $114.93
-
1 × $322.82
-
1 × $13.79
-
1 × $426.97
-
1 × $192.16
-
1 × $272.62
-
1 × $175.92
-
1 × $0.89
-
QOB370VH SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 3 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 70 AMPERE; INTERRUPTING RATING 22 KILOAMPERE; WIRE SIZE 8 TO 2 AWG (ALUMINUM/COPPER); BOLT ON MOUNTING; SIZE 4.5 INCH W X 4.9 INCH D X 5.72 INCH H; APPROVAL UL; USED ON NQ PANELBOARD
$643.59 -
QOB370 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 3 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 70 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 8 TO 2 AWG (ALUMINUM/COPPER); BOLT ON MOUNTING
$424.08 -
QOB360VH SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 3 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 60 AMPERE; INTERRUPTING RATING 22 KILOAMPERE; WIRE SIZE 8 TO 2 AWG (ALUMINUM/COPPER); BOLT ON MOUNTING; SIZE 4.5 INCH W X 4.9 INCH D X 5.72 INCH H; APPROVAL UL; USED ON NQ PANELBOARD
$505.67 -
QOB3601021 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 3 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 60 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 8 TO 2 AWG (ALUMINUM/COPPER); BOLT ON MOUNTING
$512.91 -
QOB350VH SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 3 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 50 AMPERE; INTERRUPTING RATING 22 KILOAMPERE; WIRE SIZE 8 TO 2 AWG (ALUMINUM/COPPER); BOLT ON MOUNTING; SIZE 4.5 INCH W X 4.9 INCH D X 5.72 INCH H; APPROVAL UL; USED ON NQ PANELBOARD
$505.67 -
QOB350 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 3 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 50 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 8 TO 2 AWG (ALUMINUM/COPPER); BOLT ON MOUNTING
$336.73 -
QOB345 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 3 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 45 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 8 TO 2 AWG (ALUMINUM/COPPER); BOLT ON MOUNTING
$336.73 -
QOB340VH SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 3 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 40 AMPERE; INTERRUPTING RATING 22 KILOAMPERE; WIRE SIZE 8 TO 2 AWG (ALUMINUM/COPPER); BOLT ON MOUNTING; SIZE 4.5 INCH W X 4.9 INCH D X 5.72 INCH H; APPROVAL UL; USED ON NQ PANELBOARD
$505.67 -
QOB340 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 3 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 40 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 8 TO 2 AWG (ALUMINUM/COPPER); BOLT ON MOUNTING
$336.73 -
QOB330VH SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 3 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 30 AMPERE; INTERRUPTING RATING 22 KILOAMPERE; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER); BOLT ON MOUNTING; SIZE 4.5 INCH W X 4.9 INCH D X 5.72 INCH H; APPROVAL UL
$505.67 -
QOB330 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 3 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 30 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER); BOLT ON MOUNTING
$336.73 -
QOB325 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 3 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 25 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER); BOLT ON MOUNTING
$336.73 -
QOB320VH SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 3 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 20 AMPERE; INTERRUPTING RATING 22 KILOAMPERE; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER); BOLT ON MOUNTING; SIZE 4.5 INCH W X 4.9 INCH D X 5.72 INCH H; APPROVAL UL
$505.67 -
QOB320SWN SQUARE D/TELEMECANIQUE SPECIAL APPLICATION BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; 3 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 20 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER); (2) 14 TO 10 AWG (COPPER)
$180.90 -
QOB320HID SQUARE D/TELEMECANIQUE SPECIAL APPLICATION BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 3 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 20 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 14 TO 8 AWG (ALUMINUM); (2) 14 TO 10 AWG (COPPER)
$347.97 -
QOB3201021 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 3 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 20 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER); BOLT ON MOUNTING
$512.91 -
QOB320 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 3 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 20 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER); BOLT ON MOUNTING
$336.73 -
QOB315VH SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 3 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 15 AMPERE; INTERRUPTING RATING 22 KILOAMPERE; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER); BOLT ON MOUNTING; SIZE 4.5 INCH W X 4.9 INCH D X 5.72 INCH H; APPROVAL UL
$505.67 -
QOB3150VH SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 3 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 150 AMPERE; INTERRUPTING RATING 22 KILOAMPERE; WIRE SIZE 4 AWG TO 300 KCMIL (ALUMINUM/COPPER); BOLT ON MOUNTING; SIZE 4.5 INCH W X 4.9 INCH D X 5.72 INCH H; APPROVAL UL
$2,079.01 -
QOB315 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 3 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 15 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER); BOLT ON MOUNTING
$336.73 -
QOB3125VH SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 3 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 125 AMPERE; INTERRUPTING RATING 22 KILOAMPERE; WIRE SIZE 4 AWG TO 300 KCMIL (ALUMINUM/COPPER); BOLT ON MOUNTING; SIZE 4.5 INCH W X 4.9 INCH D X 5.72 INCH H; APPROVAL UL
$2,079.01 -
QOB3125SL SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
SUB FEED LUG; 125 AMPERE; USED ON NQOD MERCHANDISED PANELBOARD; NUMBER OF POLE 3; MOUNTING BOLT ON
$187.29 -
QOB3100VH SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
BRANCH; 120/240 VAC AT 50/60 HZ; 208 VAC STAR/120 VAC AT 50/60 HZ; 120 VAC STAR/240 VAC AT 50/60 HZ (UL/CSA); 100 AMPERE; 3 POLE; INTERRUPTING RATING 22 KILOAMPERE AT 120/240 VAC; 22 KILOAMPERE AT 120 VAC STAR/240 VAC (UL/CSA)
$722.88 -
QOB3100 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 3 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 100 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 4 TO 2/0 AWG (ALUMINUM/COPPER); BOLT ON MOUNTING
$481.54 -
QOB290 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 90 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 4 TO 2/0 AWG (ALUMINUM/COPPER); BOLT ON MOUNTING
$272.75