-
1 × $0.89
-
1 × $31.87
-
1 × $118.33
-
1 × $13.79
-
1 × $688.68
-
1 × $1,052.88
-
1 × $31.53
-
1 × $193.74
-
1 × $31.11
-
1 × $31.10
-
1 × $1,862.60
-
1 × $31.10
-
1 × $43.03
-
1 × $96.60
-
1 × $31.81
-
1 × $143.36
-
1 × $273.03
-
1 × $187.68
-
1 × $84.71
-
1 × $781.72
-
1 × $113.48
-
1 × $13.51
-
1 × $25.73
-
1 × $19.16
-
1 × $1,396.65
-
1 × $3,905.89
-
1 × $118.33
-
1 × $183.69
-
1 × $10.36
-
1 × $86.43
-
1 × $158.98
-
1 × $25.12
-
1 × $539.95
-
1 × $43.03
-
1 × $95.08
-
1 × $127.77
-
1 × $31.81
-
1 × $241.53
-
1 × $100.21
-
1 × $473.17
-
1 × $351.90
-
1 × $151.08
-
1 × $1,162.13
-
1 × $230.92
-
1 × $25.12
-
1 × $24.54
-
1 × $22.45
-
1 × $13.51
-
1 × $43.26
-
1 × $86.10
-
1 × $100.10
-
1 × $268.47
-
1 × $183.23
-
1 × $439.69
-
1 × $32.49
-
1 × $546.62
-
1 × $98.49
-
1 × $162.50
-
1 × $100.21
-
1 × $546.62
-
1 × $100.21
-
1 × $230.92
-
1 × $144.12
-
1 × $27.24
-
1 × $1,211.65
-
1 × $84.61
-
1 × $1,911.52
-
1 × $137.59
-
1 × $509.96
-
1 × $13.57
-
1 × $165.39
-
1 × $114.78
-
1 × $100.10
-
QOB220 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 20 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER); (2) 14 TO 10 AWG (COPPER)
$97.41 -
QOB215VH SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 15 AMPERE; INTERRUPTING RATING 22 KILOAMPERE; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER); (2) 14 TO 10 AWG (COPPER); BOLT ON MOUNTING; SIZE 3 INCH W X 4.9 INCH D X 5.72 INCH H
$196.52 -
QOB215GFI SQUARE D/TELEMECANIQUE GROUND FAULT GFCI BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 15 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 12 TO 8 AWG (ALUMINUM); 14 TO 8 AWG (COPPER); BOLT ON MOUNTING; SIZE 1.5 INCH W X 2.91 INCH D X 4.12 INCH H; APPROVAL UL
$472.47 -
QOB215EPD SQUARE D/TELEMECANIQUE EQUIPMENT PROTECTION EPD BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 15 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 12 TO 8 AWG (ALUMINUM); 14 TO 8 AWG (COPPER); BOLT ON MOUNTING; SIZE 1.5 INCH W X 2.91 INCH D X 4.12 INCH H; APPROVAL UL
$1,237.63 -
QOB2150VH SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 150 AMPERE; INTERRUPTING RATING 22 KILOAMPERE; WIRE SIZE 4 AWG TO 300 KCMIL (ALUMINUM/COPPER); BOLT ON MOUNTING; SIZE 3 INCH W X 4.9 INCH D X 5.72 INCH H; APPROVAL UL
$1,405.55 -
QOB215 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 15 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER); (2) 14 TO 10 AWG (COPPER)
$97.41 -
QOB2125VH SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 125 AMPERE; INTERRUPTING RATING 22 KILOAMPERE; WIRE SIZE 4 AWG TO 300 KCMIL (ALUMINUM/COPPER); BOLT ON MOUNTING; SIZE 3 INCH W X 4.9 INCH D X 5.72 INCH H; APPROVAL UL
$1,275.68 -
QOB2125 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
BRANCH; 120/240 VAC AT 50/60 HZ; 208 VAC STAR/120 VAC AT 50/60 HZ; 120 VAC STAR/240 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 125 AMPERE; 2 POLE; INTERRUPTING RATING 10 KILOAMPERE AT 120 VAC; 10 KILOAMPERE AT 120 VAC STAR/240 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC
$575.78 -
QOB2110 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 110 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 4 TO 2/0 AWG (ALUMINUM/COPPER); BOLT ON MOUNTING
$575.78 -
QOB2100VH SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
BRANCH; 120/240 VAC AT 50/60 HZ; 208 VAC STAR/120 VAC AT 50/60 HZ; 120 VAC STAR/240 VAC AT 50/60 HZ (UL/CSA); 100 AMPERE; 2 POLE; INTERRUPTING RATING 22 KILOAMPERE AT 120 VAC; 22 KILOAMPERE AT 120 VAC STAR/240 VAC (UL/CSA); APPLICATION APPLIANCE; LIGHTING
$441.32 -
RSL1PRBU SQUARE D/TELEMECANIQUE
GENERAL PURPOSE PLUG-IN RELAY AND SOCKET
$26.38 -
QOB2100 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 100 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 4 TO 2/0 AWG (ALUMINUM/COPPER); BOLT ON MOUNTING
$272.75 -
QOB210 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 10 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER); (2) 14 TO 10 AWG (COPPER)
$97.41 -
QOB170 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 70 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 8 TO 2 AWG (ALUMINUM/COPPER); BOLT ON MOUNTING
$89.64 -
QOB160 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 60 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 8 TO 2 AWG (ALUMINUM/COPPER); BOLT ON MOUNTING
$42.35 -
QOB150 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 50 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 8 TO 2 AWG (ALUMINUM/COPPER); BOLT ON MOUNTING
$42.35 -
QOB140 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 40 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 8 TO 2 AWG (ALUMINUM/COPPER); BOLT ON MOUNTING
$42.35 -
QOB130VH SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 30 AMPERE; INTERRUPTING RATING 22 KILOAMPERE; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER); (2) 14 TO 10 AWG (COPPER); BOLT ON MOUNTING; APPROVAL UL; USED ON NQ PANELBOARD; QO[R] BRAND; QOB-VH MODEL
$82.75 -
QOB130HID SQUARE D/TELEMECANIQUE SPECIAL APPLICATION BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 30 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 14 TO 8 AWG (ALUMINUM); (2) 14 TO 10 AWG (COPPER); APPLICATION FLUORESCENT/HID LIGHTING
$52.67 -
QOB130GFI SQUARE D/TELEMECANIQUE GROUND FAULT GFCI BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120 VAC AT 50/60 HZ (UL/CSA); 30 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 12 TO 8 AWG (ALUMINUM); 14 TO 8 AWG (COPPER); BOLT ON MOUNTING; SIZE 0.75 INCH W X 2.91 INCH D X 4.12 INCH H; APPROVAL UL
$263.90 -
QOB130EPD SQUARE D/TELEMECANIQUE EQUIPMENT PROTECTION EPD BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120 VAC AT 50/60 HZ (UL/CSA); 30 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 12 TO 8 AWG (ALUMINUM); 14 TO 8 AWG (COPPER); BOLT ON MOUNTING; SIZE 0.75 INCH W X 2.91 INCH D X 4.12 INCH H; APPROVAL UL
$718.91 -
QOB1301021 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 30 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER); (2) 14 TO 10 AWG (COPPER); BOLT ON MOUNTING
$243.69 -
QOB130 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 30 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER); (2) 14 TO 10 AWG (COPPER); BOLT ON MOUNTING
$21.89 -
QOB125GFI SQUARE D/TELEMECANIQUE GROUND FAULT GFCI BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120 VAC AT 50/60 HZ (UL/CSA); 25 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 12 TO 8 AWG (ALUMINUM); 14 TO 8 AWG (COPPER); BOLT ON MOUNTING; SIZE 0.75 INCH W X 2.91 INCH D X 4.12 INCH H; APPROVAL UL
$263.90 -
QOB120VH SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 20 AMPERE; INTERRUPTING RATING 22 KILOAMPERE; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER); (2) 14 TO 10 AWG (COPPER); BOLT ON MOUNTING; APPROVAL UL; USED ON NQ PANELBOARD; QO[R] BRAND; QOB-VH MODEL
$82.75