-
1 × $69.97
-
1 × $266.27
-
1 × $13.85
-
1 × $360.55
-
1 × $13.79
-
1 × $202.95
-
1 × $1.79
-
1 × $546.62
-
1 × $1.79
-
1 × $15.23
-
1 × $178.61
-
1 × $179.21
-
1 × $395.30
-
1 × $236.68
-
1 × $466.85
-
1 × $417.46
-
1 × $420.41
-
1 × $267.44
-
1 × $198.49
-
1 × $222.99
-
1 × $417.28
-
1 × $190.47
-
1 × $22,379.64
-
1 × $1.78
-
1 × $203.64
-
1 × $275.66
-
1 × $26,429.76
-
1 × $201.99
-
1 × $0.89
-
1 × $1,363.68
-
1 × $1.16
-
1 × $269.55
-
1 × $152.83
-
1 × $1.13
-
1 × $307.04
-
1 × $158.62
-
1 × $5,937.22
-
1 × $206.14
-
1 × $2,423.21
-
QF230 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS GROUND FAULT GFCI PLUG-IN CIRCUIT BREAKERS
THERMAL MAGNETIC; 2 POLE; 120/240 VAC; 30 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL); 5 MILLIAMPERE TRIP SENSITIVITY; PLUG IN MOUNTING; APPROVAL CSA; QPF MODEL
$116.88 -
QF130 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS GROUND FAULT GFCI PLUG-IN CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120 VAC; 30 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120 VAC (UL); 5 MILLIAMPERE TRIP SENSITIVITY; PLUG IN MOUNTING; APPROVAL CSA; QPF MODEL
$48.69 -
QF120 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS GROUND FAULT GFCI PLUG-IN CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120 VAC; 20 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120 VAC (UL); 5 MILLIAMPERE TRIP SENSITIVITY; PLUG IN MOUNTING; APPROVAL CSA; QPF MODEL
$48.69 -
QF115 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS GROUND FAULT GFCI PLUG-IN CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120 VAC; 15 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120 VAC (UL); 5 MILLIAMPERE TRIP SENSITIVITY; PLUG IN MOUNTING; APPROVAL CSA; QPF MODEL
$48.69 -
QE250 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS EQUIPMENT PROTECTION EPD PLUG-IN CIRCUIT BREAKERS
EQUIPMENT PROTECTOR; 2 POLE; 120/240 VAC; 50 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL); PLUG IN MOUNTING; QE MODEL
$243.54 -
QE130 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS EQUIPMENT PROTECTION EPD PLUG-IN CIRCUIT BREAKERS
EQUIPMENT PROTECTOR; 1 POLE; 120 VAC; 30 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120 VAC (UL); PLUG IN MOUNTING; APPROVAL CSA; QE MODEL
$129.94 -
QE120 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS EQUIPMENT PROTECTION EPD PLUG-IN CIRCUIT BREAKERS
EQUIPMENT PROTECTOR; 1 POLE; 120 VAC; 20 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120 VAC (UL); PLUG IN MOUNTING; APPROVAL CSA; QE MODEL
$129.94 -
QE115 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS EQUIPMENT PROTECTION EPD PLUG-IN CIRCUIT BREAKERS
EQUIPMENT PROTECTOR; 1 POLE; 120 VAC; 15 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120 VAC (UL); PLUG IN MOUNTING; APPROVAL CSA; QE MODEL
$129.94 -
QDP32100TM SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 3 POLE; 240 VAC AT 50/60 HZ (UL/CSA/NOM); 240/415 VAC (IEC); 100 AMPERE; INTERRUPTING RATING 25 KILOAMPERE AT 240 VAC (UL/CSA/NOM); 10 KILOAMPERE AT 240/415 VAC (IEC); BOLT ON MOUNTING; SIZE 4.5 INCH W X 3.93 INCH D X 6.47 INCH H
$3,075.62 -
QDP22150TM SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 2 POLE; 240 VAC AT 50/60 HZ (UL/CSA/NOM); 240/415 VAC (IEC); 150 AMPERE; INTERRUPTING RATING 25 KILOAMPERE AT 240 VAC (UL/CSA/NOM); 10 KILOAMPERE AT 240/415 VAC (IEC); BOLT ON MOUNTING; SIZE 3 INCH W X 3.93 INCH D X 6.47 INCH H
$1,970.53 -
QDP22125TM SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 2 POLE; 240 VAC AT 50/60 HZ (UL/CSA/NOM); 240/415 VAC (IEC); 125 AMPERE; INTERRUPTING RATING 25 KILOAMPERE AT 240 VAC (UL/CSA/NOM); 10 KILOAMPERE AT 240/415 VAC (IEC); BOLT ON MOUNTING; SIZE 3 INCH W X 3.93 INCH D X 6.47 INCH H
$1,970.53 -
QDL32225 SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; Q FRAME; 240 VAC; 225 AMPERE; 3 POLE; INTERRUPTING RATING 25 KILOAMPERE AT 240 VAC (UL/CSA/NOM); 10 KILOAMPERE AT 240 VAC (IEC); TERMINAL LINE LUG; LOAD LUG; SIZE 4.5 INCH W X 3.93 INCH D X 6.47 INCH H; APPROVAL UL; CSA; CE
$663.25 -
QDL32200 SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; Q FRAME; 240 VAC; 200 AMPERE; 3 POLE; INTERRUPTING RATING 25 KILOAMPERE AT 240 VAC (UL/CSA/NOM); 10 KILOAMPERE AT 240 VAC (IEC); TERMINAL LINE LUG; LOAD LUG; SIZE 4.5 INCH W X 3.93 INCH D X 6.47 INCH H; APPROVAL UL; CSA; CE
$607.02 -
QDL32150 SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; Q FRAME; 240 VAC; 150 AMPERE; 3 POLE; INTERRUPTING RATING 25 KILOAMPERE AT 240 VAC (UL/CSA/NOM); 10 KILOAMPERE AT 240 VAC (IEC); TERMINAL LINE LUG; LOAD LUG; SIZE 4.5 INCH W X 3.93 INCH D X 6.47 INCH H; APPROVAL UL; CSA; CE
$607.02 -
QDL32125 SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; Q FRAME; 240 VAC; 125 AMPERE; 3 POLE; INTERRUPTING RATING 25 KILOAMPERE AT 240 VAC (UL/CSA/NOM); 10 KILOAMPERE AT 240 VAC (IEC); TERMINAL LINE LUG; LOAD LUG; SIZE 4.5 INCH W X 3.93 INCH D X 6.47 INCH H; APPROVAL UL; CSA; CE
$1,370.11 -
QDL32100 SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; Q FRAME; 240 VAC; 100 AMPERE; 3 POLE; INTERRUPTING RATING 25 KILOAMPERE AT 240 VAC (UL/CSA/NOM); 10 KILOAMPERE AT 240 VAC (IEC); TERMINAL LINE LUG; LOAD LUG; SIZE 4.5 INCH W X 3.93 INCH D X 6.47 INCH H; APPROVAL UL; CSA; CE
$1,370.11 -
QDL32080 SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; Q FRAME; 240 VAC; 80 AMPERE; 3 POLE; INTERRUPTING RATING 25 KILOAMPERE AT 240 VAC (UL/CSA/NOM); 10 KILOAMPERE AT 240 VAC (IEC); TERMINAL LINE LUG; LOAD LUG; SIZE 4.5 INCH W X 3.93 INCH D X 6.47 INCH H; APPROVAL UL; CSA; CE
$1,027.58 -
QDL32070 SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; Q FRAME; 240 VAC; 70 AMPERE; 3 POLE; INTERRUPTING RATING 25 KILOAMPERE AT 240 VAC (UL/CSA/NOM); 10 KILOAMPERE AT 240 VAC (IEC); TERMINAL LINE LUG; LOAD LUG; SIZE 4.5 INCH W X 3.93 INCH D X 6.47 INCH H; APPROVAL UL; CSA; CE
$1,370.11 -
QDL22225 SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; Q FRAME; 240 VAC; 225 AMPERE; 2 POLE; INTERRUPTING RATING 25 KILOAMPERE AT 240 VAC (UL/CSA/NOM); 10 KILOAMPERE AT 240 VAC (IEC); TERMINAL LINE LUG; LOAD LUG; SIZE 3 INCH W X 3.93 INCH D X 6.47 INCH H; APPROVAL UL; CSA; CE
$389.29 -
QDL22200 SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; Q FRAME; 240 VAC; 200 AMPERE; 2 POLE; INTERRUPTING RATING 25 KILOAMPERE AT 240 VAC (UL/CSA/NOM); 10 KILOAMPERE AT 240 VAC (IEC); TERMINAL LINE LUG; LOAD LUG; SIZE 3 INCH W X 3.93 INCH D X 6.47 INCH H; APPROVAL UL; CSA; CE
$389.29 -
QDL22150 SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; Q FRAME; 240 VAC; 150 AMPERE; 2 POLE; INTERRUPTING RATING 25 KILOAMPERE AT 240 VAC (UL/CSA/NOM); 10 KILOAMPERE AT 240 VAC (IEC); TERMINAL LINE LUG; LOAD LUG; SIZE 3 INCH W X 3.93 INCH D X 6.47 INCH H; APPROVAL UL; CSA; CE
$389.29 -
QDL22100 SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; Q FRAME; 240 VAC; 100 AMPERE; 2 POLE; INTERRUPTING RATING 25 KILOAMPERE AT 240 VAC (UL/CSA/NOM); 10 KILOAMPERE AT 240 VAC (IEC); TERMINAL LINE LUG; LOAD LUG; SIZE 3 INCH W X 3.93 INCH D X 6.47 INCH H; APPROVAL UL; CSA; CE
$658.37 -
QDA32225 SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
240 VAC AT 50/60 HZ; 225 AMPERE; 3 POLE; INTERRUPTING RATING 25 KILOAMPERE AT 240 VAC (UL/CSA/NOM/IEC); 10 KILOAMPERE AT 240 VAC (IEC); TRIP SETTING 1200 TO 2400 AMPERE; APPLICATION POWER DISTRIBUTION
$2,423.21 -
QDA32200 SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
240 VAC AT 50/60 HZ; 200 AMPERE; 3 POLE; INTERRUPTING RATING 25 KILOAMPERE AT 240 VAC (UL/CSA/NOM/IEC); 10 KILOAMPERE AT 240 VAC (IEC); TRIP SETTING 1200 TO 2400 AMPERE; APPLICATION POWER DISTRIBUTION
$2,423.21 -
QDA32175 SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
240 VAC AT 50/60 HZ; 175 AMPERE; 3 POLE; INTERRUPTING RATING 25 KILOAMPERE AT 240 VAC (UL/CSA/NOM/IEC); 10 KILOAMPERE AT 240 VAC (IEC); TRIP SETTING 1200 TO 2400 AMPERE; APPLICATION POWER DISTRIBUTION
$2,423.21