QBM22200TN SQUARE D EXACT REPLACEMENT FOR Q2M2200MT
MOLDED CASE; THERMAL MAGNETIC; Q FRAME; 240 VAC; 200 AMPERE; 2 POLE; INTERRUPTING RATING 10 KILOAMPERE; TERMINAL LINE LUG; SIZE 3 INCH W X 3.93 INCH D X 6.47 INCH H; APPROVAL UL; CSA; CE; POWERPACT[R] BRAND; QB MODEL; APPLICABLE STANDARD W-C-375B/GEN
$817.18 -
QBL32225 SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; Q FRAME; 240 VAC; 225 AMPERE; 3 POLE; INTERRUPTING RATING 10 KILOAMPERE; TERMINAL LINE LUG; LOAD LUG; SIZE 4.5 INCH W X 3.93 INCH D X 6.47 INCH H; APPROVAL UL; CSA; CE; POWERPACT[R] BRAND; QB MODEL
$424.70 -
QBL32200 SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; Q FRAME; 240 VAC; 200 AMPERE; 3 POLE; INTERRUPTING RATING 10 KILOAMPERE; TERMINAL LINE LUG; LOAD LUG; SIZE 4.5 INCH W X 3.93 INCH D X 6.47 INCH H; APPROVAL UL; CSA; CE; POWERPACT[R] BRAND; QB MODEL
$958.46 -
QBL32175 SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; Q FRAME; 240 VAC; 175 AMPERE; 3 POLE; INTERRUPTING RATING 10 KILOAMPERE; TERMINAL LINE LUG; LOAD LUG; SIZE 4.5 INCH W X 3.93 INCH D X 6.47 INCH H; APPROVAL UL; CSA; CE; POWERPACT[R] BRAND; QB MODEL
$958.46 -
QBL32125 SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; Q FRAME; 240 VAC; 125 AMPERE; 3 POLE; INTERRUPTING RATING 10 KILOAMPERE; TERMINAL LINE LUG; LOAD LUG; SIZE 4.5 INCH W X 3.93 INCH D X 6.47 INCH H; APPROVAL UL; CSA; CE; POWERPACT[R] BRAND; QB MODEL
$958.46 -
QBL22225 SQUARE D QBL 2 POLE 225 AMP BREAKER
MOLDED CASE; THERMAL MAGNETIC; Q FRAME; 240 VAC; 225 AMPERE; 2 POLE; INTERRUPTING RATING 10 KILOAMPERE; TERMINAL LINE LUG; LOAD LUG; SIZE 3 INCH W X 3.93 INCH D X 6.47 INCH H; APPROVAL UL; CSA; CE; POWERPACT[R] BRAND; QB MODEL
$161.51 -
QBL22200 200A MAIN CIRC BREAKR EA
QBL22200 200A MAIN CIRC BREAKR
$161.51 -
QBL22150 SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; Q FRAME; 240 VAC; 150 AMPERE; 2 POLE; INTERRUPTING RATING 10 KILOAMPERE; TERMINAL LINE LUG; LOAD LUG; SIZE 3 INCH W X 3.93 INCH D X 6.47 INCH H; APPROVAL UL; CSA; CE; POWERPACT[R] BRAND; QB MODEL
$161.51 -
QBL22125 SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; Q FRAME; 240 VAC; 125 AMPERE; 2 POLE; INTERRUPTING RATING 10 KILOAMPERE; TERMINAL LINE LUG; LOAD LUG; SIZE 3 INCH W X 3.93 INCH D X 6.47 INCH H; APPROVAL UL; CSA; CE; POWERPACT[R] BRAND; QB MODEL
$161.51 -
-
X-379482 ALLEN BRADLEY X379482
ALLEN BRADLEY X-379482
$165.65X-379482 ALLEN BRADLEY X379482
$165.65 -
-
QBA32225 SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
240 VAC AT 50/60 HZ; 225 AMPERE; 3 POLE; INTERRUPTING RATING 10 KILOAMPERE AT 240 VAC (UL/CSA/NOM/IEC); 10 KILOAMPERE AT 240 VAC (IEC); TRIP SETTING 1200 TO 2400 AMPERE; APPLICATION POWER DISTRIBUTION
$2,240.51 -
QBA32200 SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
240 VAC AT 50/60 HZ; 200 AMPERE; 3 POLE; INTERRUPTING RATING 10 KILOAMPERE AT 240 VAC (UL/CSA/NOM/IEC); 10 KILOAMPERE AT 240 VAC (IEC); TRIP SETTING 1200 TO 2400 AMPERE; APPLICATION POWER DISTRIBUTION
$2,240.51 -
QBA32150 SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
240 VAC AT 50/60 HZ; 150 AMPERE; 3 POLE; INTERRUPTING RATING 10 KILOAMPERE AT 240 VAC (UL/CSA/NOM/IEC); 10 KILOAMPERE AT 240 VAC (IEC); TRIP SETTING 1200 TO 2400 AMPERE; APPLICATION POWER DISTRIBUTION
$2,240.51 -
QBA32125 SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
240 VAC AT 50/60 HZ; 125 AMPERE; 3 POLE; INTERRUPTING RATING 10 KILOAMPERE AT 240 VAC (UL/CSA/NOM/IEC); 10 KILOAMPERE AT 240 VAC (IEC); TRIP SETTING 1200 TO 2400 AMPERE; APPLICATION POWER DISTRIBUTION
$2,240.51 -
QBA32100 SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
240 VAC AT 50/60 HZ; 100 AMPERE; 3 POLE; INTERRUPTING RATING 10 KILOAMPERE AT 240 VAC (UL/CSA/NOM/IEC); 10 KILOAMPERE AT 240 VAC (IEC); TRIP SETTING 1200 TO 2400 AMPERE; APPLICATION POWER DISTRIBUTION
$2,240.51 -
QBA222252 SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
240 VAC AT 50/60 HZ; 225 AMPERE; 2 POLE; INTERRUPTING RATING 10 KILOAMPERE AT 240 VAC (UL/CSA/NOM/IEC); 10 KILOAMPERE AT 240 VAC (IEC); TRIP SETTING 1200 TO 2400 AMPERE; APPLICATION POWER DISTRIBUTION
$702.72 -
QBA222002 SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
240 VAC AT 50/60 HZ; 200 AMPERE; 2 POLE; INTERRUPTING RATING 10 KILOAMPERE AT 240 VAC (UL/CSA/NOM/IEC); 10 KILOAMPERE AT 240 VAC (IEC); TRIP SETTING 1200 TO 2400 AMPERE; APPLICATION POWER DISTRIBUTION
$702.72 -
QBA222001 SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
240 VAC AT 50/60 HZ; 200 AMPERE; 2 POLE; INTERRUPTING RATING 10 KILOAMPERE AT 240 VAC (UL/CSA/NOM/IEC); 10 KILOAMPERE AT 240 VAC (IEC); TRIP SETTING 1200 TO 2400 AMPERE; APPLICATION POWER DISTRIBUTION
$702.72 -
QBA221502 SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
240 VAC AT 50/60 HZ; 150 AMPERE; 2 POLE; INTERRUPTING RATING 10 KILOAMPERE AT 240 VAC (UL/CSA/NOM/IEC); 10 KILOAMPERE AT 240 VAC (IEC); TRIP SETTING 1200 TO 2400 AMPERE; APPLICATION POWER DISTRIBUTION
$702.72 -
QBA221252 SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
240 VAC AT 50/60 HZ; 125 AMPERE; 2 POLE; INTERRUPTING RATING 10 KILOAMPERE AT 240 VAC (UL/CSA/NOM/IEC); 10 KILOAMPERE AT 240 VAC (IEC); TRIP SETTING 1200 TO 2400 AMPERE; APPLICATION POWER DISTRIBUTION
$702.72 -
QBA221251 SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
240 VAC AT 50/60 HZ; 125 AMPERE; 2 POLE; INTERRUPTING RATING 10 KILOAMPERE AT 240 VAC (UL/CSA/NOM/IEC); 10 KILOAMPERE AT 240 VAC (IEC); TRIP SETTING 1200 TO 2400 AMPERE; APPLICATION POWER DISTRIBUTION
$702.72 -
QBA221004 SQUARE D/TELEMECANIQUE NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
240 VAC AT 50/60 HZ; 100 AMPERE; 2 POLE; INTERRUPTING RATING 10 KILOAMPERE AT 240 VAC (UL/CSA/NOM/IEC); 10 KILOAMPERE AT 240 VAC (IEC); TRIP SETTING 1200 TO 2400 AMPERE; APPLICATION POWER DISTRIBUTION
$702.72 -
Zinsco replacement Q40 type Q UBIZ (THICK) 1-pole 40A
Zinsco replacement Q40 type Q UBIZ (THICK) 1-pole 40A
$40.88