-
H222N SQUARE D/TELEMECANIQUE FUSIBLE HEAVY DUTY SAFETY SWITCHES
HEAVY DUTY SAFETY; 240 V AC VOLTAGE; 250 V DC VOLTAGE; 60 AMPERE; POWER RATING 3 HP AT 240 VAC 1 PHASE; 7 1/2 HP AT 240 VAC 3 PHASE (STANDARD); 10 HP AT 240 VAC 1 PHASE; 15 HP AT 240 VAC 3 PHASE (MAXIMUM); 10 HP AT 250 VDC; 2 POLE; 3 WIRE; CLASS R FUSE
$400.35 -
H221NRB SQUARE D/TELEMECANIQUE FUSIBLE HEAVY DUTY SAFETY SWITCHES
HEAVY DUTY SAFETY; 240 V AC VOLTAGE; 250 V DC VOLTAGE; 30 AMPERE; POWER RATING 1 1/2 HP AT 240 VAC 1 PHASE; 3 HP AT 240 VAC 3 PHASE (STANDARD); 3 HP AT 240 VAC 1 PHASE; 7 1/2 HP AT 240 VAC 3 PHASE (MAXIMUM); 5 HP AT 250 VDC; 2 POLE; 3 WIRE; CLASS R FUSE
$290.55 -
H221N SQUARE D/TELEMECANIQUE FUSIBLE HEAVY DUTY SAFETY SWITCHES
HEAVY DUTY SAFETY; 240 V AC VOLTAGE; 250 V DC VOLTAGE; 30 AMPERE; POWER RATING 1 1/2 HP AT 240 VAC 1 PHASE; 3 HP AT 240 VAC 3 PHASE (STANDARD); 3 HP AT 240 VAC 1 PHASE; 7 1/2 HP AT 240 VAC 3 PHASE (MAXIMUM); 5 HP AT 250 VDC; 2 POLE; 3 WIRE; CLASS R FUSE
$200.60 -
H221DS SQUARE D/TELEMECANIQUE FUSIBLE HEAVY DUTY SAFETY SWITCHES
HEAVY DUTY SAFETY; 240 V AC VOLTAGE; 250 V DC VOLTAGE; 30 AMPERE; POWER RATING 1 1/2 HP AT 240 VAC 1 PHASE; 3 HP AT 240 VAC 3 PHASE (STANDARD); 3 HP AT 240 VAC 1 PHASE; 7 1/2 HP AT 240 VAC 3 PHASE (MAXIMUM); 5 HP AT 250 VDC; 2 POLE; 2 WIRE; CLASS R FUSE
$1,362.90 -
H221AWK SQUARE D/TELEMECANIQUE FUSIBLE HEAVY DUTY SAFETY SWITCHES
HEAVY DUTY SAFETY; 240 V AC VOLTAGE; 250 V DC VOLTAGE; 30 AMPERE; POWER RATING 1 1/2 HP AT 240 VAC 1 PHASE; 3 HP AT 240 VAC 3 PHASE (STANDARD); 3 HP AT 240 VAC 1 PHASE; 7 1/2 HP AT 240 VAC 3 PHASE (MAXIMUM); 5 HP AT 250 VDC; 2 POLE; 2 WIRE; CLASS R FUSE
$438.00 -
H2117B-3 CUTLER-HAMMER DISTRIBUTION EQUIPMENT/CONTROLS THERMAL OVERLOAD HEATER ELEMENTS
CLASS 10; FAST TRIP; MOTOR FLA 53.8 TO 74.9 AMPERE; 75 AMPERE RELAY CURRENT; 2 NEMA SIZE; G TO K IEC SIZE; APPROVAL UL; CSA; CE; STANDARD PACKAGE 3; USED ON OVERLOAD RELAY
$70.38 -
H2114B-3 CUTLER-HAMMER DISTRIBUTION EQUIPMENT/CONTROLS THERMAL OVERLOAD HEATER ELEMENTS
CLASS 10; FAST TRIP; MOTOR FLA 23.5 TO 34.8 AMPERE; 32/75 AMPERE RELAY CURRENT; 00; 0; 1; 2 NEMA SIZE; A TO K IEC SIZE; APPROVAL UL; CSA; CE; STANDARD PACKAGE 3; USED ON OVERLOAD RELAY
$70.38 -
H2112B-3 CUTLER-HAMMER DISTRIBUTION EQUIPMENT/CONTROLS THERMAL OVERLOAD HEATER ELEMENTS
CLASS 10; FAST TRIP; MOTOR FLA 14.4 TO 23.8 AMPERE; 32/75 AMPERE RELAY CURRENT; 00; 0; 1; 2 NEMA SIZE; A TO K IEC SIZE; APPROVAL UL; CSA; CE; STANDARD PACKAGE 3; USED ON OVERLOAD RELAY
$70.38 -
H2111B-3 CUTLER-HAMMER DISTRIBUTION EQUIPMENT/CONTROLS THERMAL OVERLOAD HEATER ELEMENTS
CLASS 10; FAST TRIP; MOTOR FLA 9.6 TO 14.4 AMPERE; 32/75 AMPERE RELAY CURRENT; 00; 0; 1; 2 NEMA SIZE; A TO K IEC SIZE; APPROVAL UL; CSA; CE; STANDARD PACKAGE 3; USED ON OVERLOAD RELAY
$70.38 -
H2110B-3 CUTLER-HAMMER DISTRIBUTION EQUIPMENT/CONTROLS THERMAL OVERLOAD HEATER ELEMENTS
CLASS 10; FAST TRIP; MOTOR FLA 7.07 TO 11.6 AMPERE; 32/75 AMPERE RELAY CURRENT; 00; 0; 1; 2 NEMA SIZE; A TO K IEC SIZE; APPROVAL UL; CSA; CE; STANDARD PACKAGE 3; USED ON OVERLOAD RELAY
$70.38 -
H2108B-3 CUTLER-HAMMER DISTRIBUTION EQUIPMENT/CONTROLS THERMAL OVERLOAD HEATER ELEMENTS
CLASS 10; FAST TRIP; MOTOR FLA 3.38 TO 5.54 AMPERE; 32/75 AMPERE RELAY CURRENT; 00; 0; 1; 2 NEMA SIZE; A TO K IEC SIZE; APPROVAL UL; CSA; CE; STANDARD PACKAGE 3; USED ON OVERLOAD RELAY
$70.38 -
H2106B-3 CUTLER-HAMMER DISTRIBUTION EQUIPMENT/CONTROLS THERMAL OVERLOAD HEATER ELEMENTS
CLASS 10; FAST TRIP; MOTOR FLA 1.92 TO 3.15 AMPERE; 32/75 AMPERE RELAY CURRENT; 00; 0; 1; 2 NEMA SIZE; A TO K IEC SIZE; APPROVAL UL; CSA; CE; STANDARD PACKAGE 3; USED ON OVERLOAD RELAY
$70.38 -
H2104B-3 CUTLER-HAMMER DISTRIBUTION EQUIPMENT/CONTROLS THERMAL OVERLOAD HEATER ELEMENTS
CLASS 10; FAST TRIP; MOTOR FLA 0.846 TO 1.37 AMPERE; 32/75 AMPERE RELAY CURRENT; 00; 0; 1; 2 NEMA SIZE; A TO K IEC SIZE; APPROVAL UL; CSA; CE; STANDARD PACKAGE 3; USED ON OVERLOAD RELAY
$70.38 -
H2027-3 CUTLER-HAMMER CONTROLS/DISTRIBUTION EQUIPMENT THERMAL OVERLOAD HEATER ELEMENTS
CLASS 20; STANDARD TRIP; MOTOR FLA 14.3 TO 19 AMPERE; 105/144 AMPERE RELAY CURRENT; 3; 4 NEMA SIZE; L TO N IEC SIZE; APPROVAL UL; CSA; CE; STANDARD PACKAGE 3; USED ON OVERLOAD RELAY
$85.53 -
H2026-3 CUTLER-HAMMER CONTROLS/DISTRIBUTION EQUIPMENT THERMAL OVERLOAD HEATER ELEMENTS
CLASS 20; STANDARD TRIP; MOTOR FLA 11.4 TO 15.7 AMPERE; 105/144 AMPERE RELAY CURRENT; 3; 4 NEMA SIZE; L TO N IEC SIZE; APPROVAL UL; CSA; CE; STANDARD PACKAGE 3; USED ON OVERLOAD RELAY
$85.53 -
H2025-3 CUTLER-HAMMER CONTROLS/DISTRIBUTION EQUIPMENT THERMAL OVERLOAD HEATER ELEMENTS
CLASS 20; STANDARD TRIP; MOTOR FLA 8 TO 11.5 AMPERE; 105/144 AMPERE RELAY CURRENT; 3; 4 NEMA SIZE; L TO N IEC SIZE; APPROVAL UL; CSA; CE; STANDARD PACKAGE 3; USED ON OVERLOAD RELAY
$85.53 -
H2024-3 CUTLER HAMMER HEATERS PACK OF 3
CLASS 20; STANDARD TRIP; MOTOR FLA 106 TO 144 AMPERE; 105/144 AMPERE RELAY CURRENT; 3; 4 NEMA SIZE; L TO N IEC SIZE; APPROVAL UL; CSA; CE; STANDARD PACKAGE 3; USED ON OVERLOAD RELAY
$85.53 -
H2023-3 CUTLER-HAMMER DISTRIBUTION EQUIPMENT/CONTROLS THERMAL OVERLOAD HEATER ELEMENTS
CLASS 20; STANDARD TRIP; MOTOR FLA 84.7 TO 115 AMPERE; 105/144 AMPERE RELAY CURRENT; 3; 4 NEMA SIZE; L TO N IEC SIZE; APPROVAL UL; CSA; CE; STANDARD PACKAGE 3; USED ON OVERLOAD RELAY
$85.53 -
H2022-3 CUTLER-HAMMER DISTRIBUTION EQUIPMENT/CONTROLS THERMAL OVERLOAD HEATER ELEMENTS
CLASS 20; STANDARD TRIP; MOTOR FLA 62.2 TO 84.6 AMPERE; 105/144 AMPERE RELAY CURRENT; 3; 4 NEMA SIZE; L TO N IEC SIZE; APPROVAL UL; CSA; CE; STANDARD PACKAGE 3; USED ON OVERLOAD RELAY
$85.53 -
H2021-3 CUTLER-HAMMER DISTRIBUTION EQUIPMENT/CONTROLS THERMAL OVERLOAD HEATER ELEMENTS
CLASS 20; STANDARD TRIP; MOTOR FLA 45.7 TO 62.1 AMPERE; 105/144 AMPERE RELAY CURRENT; 3; 4 NEMA SIZE; L TO N IEC SIZE; APPROVAL UL; CSA; CE; STANDARD PACKAGE 3; USED ON OVERLOAD RELAY
$85.53 -
H2020-3 CUTLER-HAMMER DISTRIBUTION EQUIPMENT/CONTROLS THERMAL OVERLOAD HEATER ELEMENTS
CLASS 20; STANDARD TRIP; MOTOR FLA 33.5 TO 45.6 AMPERE; 105/144 AMPERE RELAY CURRENT; 3; 4 NEMA SIZE; L TO N IEC SIZE; APPROVAL UL; CSA; CE; STANDARD PACKAGE 3; USED ON OVERLOAD RELAY
$85.53 -
H2019-3 CUTLER-HAMMER DISTRIBUTION EQUIPMENT/CONTROLS THERMAL OVERLOAD HEATER ELEMENTS
CLASS 20; STANDARD TRIP; MOTOR FLA 24.6 TO 33.4 AMPERE; 105/144 AMPERE RELAY CURRENT; 3; 4 NEMA SIZE; L TO N IEC SIZE; APPROVAL UL; CSA; CE; STANDARD PACKAGE 3; USED ON OVERLOAD RELAY
$85.53 -
H2018-3 CUTLER-HAMMER DISTRIBUTION EQUIPMENT/CONTROLS THERMAL OVERLOAD HEATER ELEMENTS
CLASS 20; STANDARD TRIP; MOTOR FLA 18 TO 24.5 AMPERE; 105/144 AMPERE RELAY CURRENT; 3; 4 NEMA SIZE; L TO N IEC SIZE; APPROVAL UL; CSA; CE; STANDARD PACKAGE 3; USED ON OVERLOAD RELAY
$85.53 -
H2017B-3 CUTLER-HAMMER DISTRIBUTION EQUIPMENT/CONTROLS THERMAL OVERLOAD HEATER ELEMENTS
CLASS 20; STANDARD TRIP; MOTOR FLA 53.9 TO 74.9 AMPERE; 75 AMPERE RELAY CURRENT; 2 NEMA SIZE; G TO K IEC SIZE; APPROVAL UL; CSA; CE; STANDARD PACKAGE 3; USED ON OVERLOAD RELAY
$85.53 -
H2016B-3 CUTLER-HAMMER DISTRIBUTION EQUIPMENT/CONTROLS THERMAL OVERLOAD HEATER ELEMENTS
CLASS 20; STANDARD TRIP; MOTOR FLA 39.6 TO 57.4 AMPERE; 75 AMPERE RELAY CURRENT; 2 NEMA SIZE; G TO K IEC SIZE; APPROVAL UL; CSA; CE; STANDARD PACKAGE 3; USED ON OVERLOAD RELAY
$85.53