-
1 × $52.75
-
1 × $243.31
-
1 × $279.68
-
1 × $227.70
-
1 × $142.85
-
1 × $57.48
-
1 × $198.08
-
1 × $108.49
-
1 × $214.08
-
1 × $137.53
-
1 × $31.60
-
1 × $97.67
-
1 × $152.89
-
1 × $12.35
-
1 × $13.63
-
1 × $122.36
-
1 × $243.31
-
1 × $177.63
-
1 × $95.50
-
1 × $1,839.25
-
1 × $158.65
-
1 × $270.36
-
1 × $228.80
-
1 × $65.11
-
1 × $100.97
-
1 × $1,765.38
-
1 × $7,175.24
-
1 × $95.51
-
1 × $207.03
-
1 × $1.62
-
1 × $149.72
-
1 × $8.74
-
1 × $19.43
-
1 × $141.14
-
1 × $308.50
-
1 × $222.63
-
1 × $2.06
-
1 × $257.30
-
1 × $76.13
-
1 × $1,759.50
-
1 × $1,791.98
-
1 × $14.71
-
1 × $288.43
-
1 × $107.34
-
1 × $16.82
-
1 × $123.11
-
1 × $994.10
-
1 × $7,150.53
-
1 × $11.24
-
1 × $142.85
-
1 × $74.08
-
1 × $19.16
-
1 × $83.08
-
1 × $81.72
-
1 × $772.80
-
1 × $109.32
-
1 × $8.74
-
1 × $258.41
-
1 × $117.38
-
1 × $81.72
-
QOB280 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 80 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 4 TO 2/0 AWG (ALUMINUM/COPPER); BOLT ON MOUNTING
$272.75 -
QOB270 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 70 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 8 TO 2 AWG (ALUMINUM/COPPER); BOLT ON MOUNTING
$193.08 -
QOB260VH SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 60 AMPERE; INTERRUPTING RATING 22 KILOAMPERE; WIRE SIZE 8 TO 2 AWG (ALUMINUM/COPPER); BOLT ON MOUNTING; SIZE 3 INCH W X 4.9 INCH D X 5.72 INCH H; APPROVAL UL; USED ON NQ PANELBOARD
$196.52 -
QOB260GFI SQUARE D/TELEMECANIQUE GROUND FAULT GFCI BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 60 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 12 TO 4 AWG (ALUMINUM); 14 TO 6 AWG (COPPER); BOLT ON MOUNTING; SIZE 1.5 INCH W X 2.91 INCH D X 4.12 INCH H; APPROVAL UL
$472.47 -
QOB260EPD SQUARE D/TELEMECANIQUE EQUIPMENT PROTECTION EPD BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 60 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 12 TO 4 AWG (ALUMINUM); 14 TO 6 AWG (COPPER); BOLT ON MOUNTING; SIZE 1.5 INCH W X 2.91 INCH D X 4.12 INCH H; APPROVAL UL
$1,237.63 -
QOB260 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 60 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 8 TO 2 AWG (ALUMINUM/COPPER); BOLT ON MOUNTING
$97.41 -
QOB250VH SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 50 AMPERE; INTERRUPTING RATING 22 KILOAMPERE; WIRE SIZE 8 TO 2 AWG (ALUMINUM/COPPER); BOLT ON MOUNTING; SIZE 3 INCH W X 4.9 INCH D X 5.72 INCH H; APPROVAL UL; USED ON NQ PANELBOARD
$196.52 -
QOB250EPD SQUARE D/TELEMECANIQUE EQUIPMENT PROTECTION EPD BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 50 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 12 TO 4 AWG (ALUMINUM); 14 TO 6 AWG (COPPER); BOLT ON MOUNTING; SIZE 1.5 INCH W X 2.91 INCH D X 4.12 INCH H; APPROVAL UL
$1,237.63 -
QOB2501021 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 50 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 8 TO 2 AWG (ALUMINUM/COPPER); BOLT ON MOUNTING
$295.83 -
QOB250 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 50 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 8 TO 2 AWG (ALUMINUM/COPPER); BOLT ON MOUNTING
$97.41 -
QOB245 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 45 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 8 TO 2 AWG (ALUMINUM/COPPER); BOLT ON MOUNTING
$97.41 -
QOB240VH SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 40 AMPERE; INTERRUPTING RATING 22 KILOAMPERE; WIRE SIZE 8 TO 2 AWG (ALUMINUM/COPPER); BOLT ON MOUNTING; SIZE 3 INCH W X 4.9 INCH D X 5.72 INCH H; APPROVAL UL; USED ON NQ PANELBOARD
$196.52 -
QOB240EPD SQUARE D/TELEMECANIQUE EQUIPMENT PROTECTION EPD BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 40 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 12 TO 4 AWG (ALUMINUM); 14 TO 6 AWG (COPPER); BOLT ON MOUNTING; SIZE 1.5 INCH W X 2.91 INCH D X 4.12 INCH H; APPROVAL UL
$1,237.63 -
QOB240 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 40 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 8 TO 2 AWG (ALUMINUM/COPPER); BOLT ON MOUNTING
$97.41 -
QOB235 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 35 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 8 TO 2 AWG (ALUMINUM/COPPER); BOLT ON MOUNTING
$97.41 -
QOB230VH SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 30 AMPERE; INTERRUPTING RATING 22 KILOAMPERE; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER); (2) 14 TO 10 AWG (COPPER); BOLT ON MOUNTING; SIZE 3 INCH W X 4.9 INCH D X 5.72 INCH H
$196.52 -
QOB230SWN SQUARE D/TELEMECANIQUE SPECIAL APPLICATION BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; 2 POLE; 120 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 30 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER); (2) 14 TO 10 AWG (COPPER); APPLICATION HACR
$123.44 -
QOB230HID SQUARE D/TELEMECANIQUE SPECIAL APPLICATION BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 30 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 14 TO 8 AWG (ALUMINUM); (2) 14 TO 10 AWG (COPPER)
$114.93 -
QOB2301021 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 30 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER); (2) 14 TO 10 AWG (COPPER)
$295.83 -
QOB230 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 30 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER); (2) 14 TO 10 AWG (COPPER)
$97.41 -
QOB220VH SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 20 AMPERE; INTERRUPTING RATING 22 KILOAMPERE; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER); (2) 14 TO 10 AWG (COPPER); BOLT ON MOUNTING; SIZE 3 INCH W X 4.9 INCH D X 5.72 INCH H
$196.52 -
QOB220SWN SQUARE D/TELEMECANIQUE SPECIAL APPLICATION BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; 2 POLE; 120 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 20 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER); (2) 14 TO 10 AWG (COPPER); APPLICATION HACR
$123.44 -
QOB220GFI SQUARE D/TELEMECANIQUE GROUND FAULT GFCI BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 20 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 12 TO 8 AWG (ALUMINUM); 14 TO 8 AWG (COPPER); BOLT ON MOUNTING; SIZE 1.5 INCH W X 2.91 INCH D X 4.12 INCH H; APPROVAL UL
$266.40 -
QOB220EPD SQUARE D/TELEMECANIQUE EQUIPMENT PROTECTION EPD BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 20 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 12 TO 8 AWG (ALUMINUM); 14 TO 8 AWG (COPPER); BOLT ON MOUNTING; SIZE 1.5 INCH W X 2.91 INCH D X 4.12 INCH H; APPROVAL UL
$1,237.63 -
QOB2201021 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
COMMON TRIP; THERMAL MAGNETIC; 2 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 20 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER); (2) 14 TO 10 AWG (COPPER)
$295.83