1 × $4.83
-
1 × $53.28
-
1 × $911.10
-
1 × $42.26
-
1 × $191.53
-
1 × $82.84
-
1 × $33.93
-
1 × $278.70
-
1 × $58.53
-
1 × $53.47
-
1 × $5,210.47
-
1 × $118.72
-
1 × $38.76
-
1 × $1,131.21
-
1 × $180.29
-
1 × $83.08
-
1 × $70.21
-
1 × $152.49
-
1 × $33.93
-
1 × $913.77
-
1 × $1,633.16
-
1 × $3,716.51
-
1 × $334.30
-
1 × $914.94
-
1 × $119.27
-
1 × $108.50
-
1 × $3.11
-
1 × $120.58
-
1 × $471.32
-
1 × $191.22
-
1 × $345.06
-
1 × $264.08
-
1 × $249.17
-
1 × $100.21
-
1 × $1,052.91
-
1 × $1,266.84
-
1 × $456.92
-
1 × $126.13
-
1 × $1,128.82
-
1 × $92.92
-
1 × $85.68
-
1 × $688.07
-
1 × $747.60
-
1 × $214.58
-
1 × $1,403.82
-
1 × $124.30
-
1 × $11.37
-
1 × $191.91
-
QO120M100 SQUARE D/TELEMECANIQUE SINGLE PHASE CONVERTIBLE LOAD CENTERS
CONVERTIBLE MAIN; 120/240 VAC; 100 AMPERE; 20 MAXIMUM CIRCUIT(S); 20 MAXIMUM SPACE(S); QOM1 FRAME SIZE MAIN BREAKER; INTERRUPTING RATING 22 KILOAMPERE; COPPER BUS MATERIAL; MAIN WIRE SIZE 4 TO 1 AWG (ALUMINUM/COPPER); INDOOR ENCLOSURE
$152.59 -
QO120L125G SQUARE D/TELEMECANIQUE SINGLE PHASE CONVERTIBLE LOAD CENTERS
CONVERTIBLE MAIN; 120/240 VAC; 125 AMPERE; 20 MAXIMUM CIRCUIT(S); 20 MAXIMUM SPACE(S); QOM1 FRAME SIZE MAIN BREAKER; INTERRUPTING RATING 65 KILOAMPERE; COPPER BUS MATERIAL; MAIN WIRE SIZE 4 TO 2/0 AWG (ALUMINUM/COPPER); INDOOR ENCLOSURE
$274.48 -
QO120HM SQUARE D/TELEMECANIQUE SPECIAL APPLICATION PLUG-IN CIRCUIT BREAKERS
HIGH MAGNETIC; 1 POLE; 120 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 20 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 14 TO 8 AWG (ALUMINUM); (2) 14 TO 10 AWG (COPPER); APPLICATION HACR; DIMMER; PLUG ON MOUNTING
$28.75 -
QO120HID SQUARE D/TELEMECANIQUE SPECIAL APPLICATION PLUG-IN CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 20 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 14 TO 8 AWG (ALUMINUM); (2) 14 TO 10 AWG (COPPER)
$65.68 -
QO120GFI SQUARE D/TELEMECANIQUE GROUND FAULT GFCI PLUG-IN CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120 VAC AT 60 HZ; 20 AMPERE; INTERRUPTING RATING 10000 AMPERE; 6 MILLIAMPERE TRIP SENSITIVITY; WIRE SIZE 14 TO 8 AWG (COPPER); 12 TO 8 AWG (ALUMINUM); PLUG ON MOUNTING; SIZE 0.75 INCH W X 2.91 INCH D X 4.12 INCH H; APPROVAL NOM
$95.23 -
QO120EPD SQUARE D/TELEMECANIQUE
THERMAL MAGNETIC; 1 POLE; 120 VAC AT 50/60 HZ (UL/CSA); 20 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; SIZE 0.75 INCH W X 2.91 INCH D X 4.12 INCH H; QO[R] BRAND; QO-EPD MODEL
$258.30QO120EPD SQUARE D/TELEMECANIQUE
$258.30 -
-
QO120CAFI SQUARE D AFCI COMBINATION BREAKER
THERMAL MAGNETIC; 1 POLE; 120 VAC AT 50/60 HZ (UL/CSA); 20 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 12 TO 8 AWG (ALUMINUM); 14 TO 8 AWG (COPPER); APPLICATION ARC FAULT; HACR; WITH ARC FAULT CIRCUIT INTERRUPTER; PLUG ON MOUNTING
$60.23 -
QO120AFI SQUARE D/TELEMECANIQUE ARC FAULT AFCI PLUG-IN CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120 VAC AT 50/60 HZ (UL/CSA); 20 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 12 TO 8 AWG (ALUMINUM); 14 TO 8 AWG (COPPER); APPLICATION ARC FAULT; HACR; WITH ARC FAULT CIRCUIT INTERRUPTER; PLUG ON MOUNTING
$63.20 -
QO12040M200RB SQUARE D/TELEMECANIQUE SINGLE PHASE CONVERTIBLE LOAD CENTERS
CONVERTIBLE MAIN; 120/240 VAC; 200 AMPERE; 40 MAXIMUM CIRCUIT(S); 20 MAXIMUM SPACE(S); QOM2 FRAME SIZE MAIN BREAKER; INTERRUPTING RATING 22 KILOAMPERE; COPPER BUS MATERIAL; MAIN WIRE SIZE 4 AWG TO 250 KCMIL (ALUMINUM/COPPER)
$455.44 -
QO12030M150C SQUARE D/TELEMECANIQUE SINGLE PHASE CONVERTIBLE LOAD CENTERS
CONVERTIBLE MAIN/MAIN BREAKER/MAIN LUG; 120/240 VAC; 150 AMPERE; 30 MAXIMUM CIRCUIT(S); 20 MAXIMUM SPACE(S); QOM2 MAIN FRAME SIZE MAIN BREAKER; INTERRUPTING RATING 22 KILOAMPERE; COPPER BUS MATERIAL; MAIN WIRE SIZE 4 AWG TO 250 KCMIL (ALUMINUM/COPPER)
$988.84 -
QO12030L150G SQUARE D/TELEMECANIQUE SINGLE PHASE CONVERTIBLE LOAD CENTERS
CONVERTIBLE MAIN; 120/240 VAC; 150 AMPERE; 30 MAXIMUM CIRCUIT(S); 20 MAXIMUM SPACE(S); QOM2 FRAME SIZE MAIN BREAKER; INTERRUPTING RATING 65 KILOAMPERE; COPPER BUS MATERIAL; MAIN WIRE SIZE 4 AWG TO 250 KCMIL (ALUMINUM/COPPER); INDOOR ENCLOSURE
$389.44 -
QO12024L125G SQUARE D/TELEMECANIQUE SINGLE PHASE CONVERTIBLE LOAD CENTERS
CONVERTIBLE MAIN; 120/240 VAC; 125 AMPERE; 24 MAXIMUM CIRCUIT(S); 20 MAXIMUM SPACE(S); QOM1 FRAME SIZE MAIN BREAKER; INTERRUPTING RATING 65 KILOAMPERE; COPPER BUS MATERIAL; MAIN WIRE SIZE 4 TO 2/0 AWG (ALUMINUM/COPPER); INDOOR ENCLOSURE
$390.61 -
QO1201021 SQUARE D/TELEMECANIQUE STANDARD TRIP PLUG-IN CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 20 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER); (2) 14 TO 10 AWG (COPPER); PLUG ON MOUNTING
$204.83 -
QO120 SQUARE D/TELEMECANIQUE STANDARD TRIP PLUG-IN CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 20 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER); (2) 14 TO 10 AWG (COPPER); PLUG ON MOUNTING
$13.77 -
QO116L125G SQUARE D/TELEMECANIQUE SINGLE PHASE CONVERTIBLE LOAD CENTERS
CONVERTIBLE MAIN; 120/240 VAC; 125 AMPERE; 16 MAXIMUM CIRCUIT(S); 16 MAXIMUM SPACE(S); QOM1 FRAME SIZE MAIN BREAKER; INTERRUPTING RATING 65 KILOAMPERE; COPPER BUS MATERIAL; MAIN WIRE SIZE 4 TO 2/0 AWG (ALUMINUM/COPPER); INDOOR ENCLOSURE
$255.71 -
QO11624L125G SQUARE D/TELEMECANIQUE SINGLE PHASE CONVERTIBLE LOAD CENTERS
CONVERTIBLE MAIN; 120/240 VAC; 125 AMPERE; 24 MAXIMUM CIRCUIT(S); 16 MAXIMUM SPACE(S); QOM1 FRAME SIZE MAIN BREAKER; INTERRUPTING RATING 65 KILOAMPERE; COPPER BUS MATERIAL; MAIN WIRE SIZE 4 TO 2/0 AWG (ALUMINUM/COPPER); INDOOR ENCLOSURE
$308.50 -
QO115VH SQUARE D/TELEMECANIQUE STANDARD TRIP PLUG-IN CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 15 AMPERE; INTERRUPTING RATING 22 KILOAMPERE; WIRE SIZE 14 TO 8 AWG (ALUMINUM/COPPER); (2) 14 TO 10 AWG (COPPER); PLUG ON MOUNTING; SIZE 0.75 INCH W X 2.91 INCH D X 3 INCH H; APPROVAL UL
$58.82 -
QO115PL SQUARE D/TELEMECANIQUE STANDARD TRIP PLUG-IN CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; 1 POLE; 120/240 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 15 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120/240 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; LUG TERMINAL; WIRE SIZE 12 TO 2 AWG (ALUMINUM); 14 TO 2 AWG (COPPER)
$135.60 -
QO115K SQUARE D/TELEMECANIQUE STANDARD TRIP PLUG-IN CIRCUIT BREAKERS
1 POLE; 120 VAC; 15 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; PLUG ON MOUNTING; APPROVAL UL; USED ON QO[R] LOAD CENTER; QO[R] BRAND; QO-K MODEL
$192.37 -
QO115HM SQUARE D/TELEMECANIQUE SPECIAL APPLICATION PLUG-IN CIRCUIT BREAKERS
HIGH MAGNETIC; 1 POLE; 120 VAC AT 50/60 HZ (UL/CSA); 48 VDC; 15 AMPERE; INTERRUPTING RATING 10 KILOAMPERE AT 120 VAC (UL/CSA); 5 KILOAMPERE AT 48 VDC; WIRE SIZE 14 TO 8 AWG (ALUMINUM); (2) 14 TO 10 AWG (COPPER); APPLICATION HACR; DIMMER; PLUG ON MOUNTING
$28.75 -
QO115GFI SQUARE D/TELEMECANIQUE GROUND FAULT GFCI PLUG-IN CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120 VAC AT 60 HZ; 15 AMPERE; INTERRUPTING RATING 10000 AMPERE; 6 MILLIAMPERE TRIP SENSITIVITY; WIRE SIZE 14 TO 8 AWG (COPPER); 12 TO 8 AWG (ALUMINUM); PLUG ON MOUNTING; SIZE 0.75 INCH W X 2.91 INCH D X 4.12 INCH H; APPROVAL NOM
$95.23 -
QO115CAFI SQUARE D/TELEMECANIQUE ARC FAULT AFCI PLUG-IN CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120 VAC AT 50/60 HZ (UL/CSA); 15 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 12 TO 8 AWG (ALUMINUM); 14 TO 8 AWG (COPPER); APPLICATION ARC FAULT; HACR; WITH ARC FAULT CIRCUIT INTERRUPTER; PLUG ON MOUNTING
$60.23