	CH120GF CUTLER-HAMMER DISTRIBUTION EQUIPMENT/CONTROLS GROUND FAULT GFCI PLUG-IN CIRCUIT BREAKERSTHERMAL MAGNETIC; 1 POLE; 120 VAC; 20 AMPERE; INTERRUPTING RATING 10000 AMPERE; 5 MILLIAMPERE TRIP SENSITIVITY; WIRE SIZE 14 TO 6 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; CSA; USED ON LOADCENTER; CH MODEL $64.91
- 
	CH120 CUTLER-HAMMER DISTRIBUTION EQUIPMENT/CONTROLS STANDARD TRIP PLUG-IN CIRCUIT BREAKERSTHERMAL MAGNETIC; 1 POLE; 120/240 VAC; 20 AMPERE; INTERRUPTING RATING 10000 AMPERE; PLUG ON MOUNTING; APPROVAL UL 489; CSA; USED ON LOAD CENTER; CH MODEL $7.44
- 
	CH115GF CUTLER-HAMMER DISTRIBUTION EQUIPMENT/CONTROLS GROUND FAULT GFCI PLUG-IN CIRCUIT BREAKERSTHERMAL MAGNETIC; 1 POLE; 120 VAC; 15 AMPERE; INTERRUPTING RATING 10000 AMPERE; 5 MILLIAMPERE TRIP SENSITIVITY; WIRE SIZE 14 TO 6 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; CSA; USED ON LOADCENTER; CH MODEL $64.91
- 
	CH115AF CUTLER-HAMMER CONTROLS/DISTRIBUTION EQUIPMENT ARC FAULT AFCI PLUG-IN CIRCUIT BREAKERSTHERMAL MAGNETIC; 1 POLE; 120 VAC; 15 AMPERE; INTERRUPTING RATING 10000 AMPERE; SIZE 3/4 INCH W; APPROVAL UL 1699; USED ON LOAD CENTER; FIRE-GUARD[T] BRAND; CH MODEL $77.70
- 
	CH115 CUTLER-HAMMER DISTRIBUTION EQUIPMENT/CONTROLS STANDARD TRIP PLUG-IN CIRCUIT BREAKERSTHERMAL MAGNETIC; 1 POLE; 120/240 VAC; 15 AMPERE; INTERRUPTING RATING 10000 AMPERE; WIRE SIZE (2) 14 TO 10 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; CSA; USED ON LOAD CENTER; CH MODEL $7.44
- 
	CH110 CUTLER-HAMMER DISTRIBUTION EQUIPMENT/CONTROLS STANDARD TRIP PLUG-IN CIRCUIT BREAKERSTHERMAL MAGNETIC; 1 POLE; 120/240 VAC; 10 AMPERE; INTERRUPTING RATING 10000 AMPERE; WIRE SIZE (1) 14 TO 8 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; CSA; USED ON LOAD CENTER; CH MODEL $7.70
- 
	CFD63B225 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERSFUSELESS CURRENT LIMITING; MOLDED CASE; THERMAL MAGNETIC; FD FRAME; 600 VAC AT 50/60 HZ; 500 VDC; 225 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 200 KILOAMPERE AT 240/480 VAC; 100 KILOAMPERE AT 600 VAC; 50 KILOAMPERE AT 500 VDC (UL) $2,191.80
- 
	CEL18-10 ABB CONTACTOR AUXILIARY CONTACT BLOCKABB CEL18-10 CONTACTOR AUXILIARY CONTACT BLOCK A95-AF1650 AUX;1NO LOW ENERGY $15.11
- 
	CEL18-01 ABB CONTACTOR AUXILIARY CONTACT BLOCKABB CEL18-01 CONTACTOR AUXILIARY CONTACT BLOCK A95-AF1650 AUX; INC LOW ENERGY $15.11
- 
	CED63B100 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERSFUSELESS CURRENT LIMITING; THERMAL MAGNETIC; 3 POLE; 600 VAC; 500 VDC; 100 AMPERE AT 40 DEG C; INTERRUPTING RATING 200 KILOAMPERE AT 240/480 VAC; 100 KILOAMPERE AT 600 VAC; 50 KILOAMPERE AT 500 VDC (UL); LUG LOAD TERMINAL TERMINAL $1,071.43
- 
	CED63B080 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERSFUSELESS CURRENT LIMITING; THERMAL MAGNETIC; 3 POLE; 600 VAC; 500 VDC; 80 AMPERE AT 40 DEG C; INTERRUPTING RATING 200 KILOAMPERE AT 240/480 VAC; 100 KILOAMPERE AT 600 VAC; 50 KILOAMPERE AT 500 VDC (UL); LUG LOAD TERMINAL TERMINAL $1,071.43
- 
	CED63B060 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERSFUSELESS CURRENT LIMITING; THERMAL MAGNETIC; 3 POLE; 600 VAC; 500 VDC; 60 AMPERE AT 40 DEG C; INTERRUPTING RATING 200 KILOAMPERE AT 240/480 VAC; 100 KILOAMPERE AT 600 VAC; 50 KILOAMPERE AT 500 VDC (UL); LUG LOAD TERMINAL TERMINAL $1,071.43
- 
	CED63B050 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERSFUSELESS CURRENT LIMITING; THERMAL MAGNETIC; 3 POLE; 600 VAC; 500 VDC; 50 AMPERE AT 40 DEG C; INTERRUPTING RATING 200 KILOAMPERE AT 240/480 VAC; 100 KILOAMPERE AT 600 VAC; 50 KILOAMPERE AT 500 VDC (UL); LUG LOAD TERMINAL TERMINAL $1,071.43
- 
	CED63B040 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERSFUSELESS CURRENT LIMITING; THERMAL MAGNETIC; 3 POLE; 600 VAC; 500 VDC; 40 AMPERE AT 40 DEG C; INTERRUPTING RATING 200 KILOAMPERE AT 240/480 VAC; 100 KILOAMPERE AT 600 VAC; 50 KILOAMPERE AT 500 VDC (UL); LUG LOAD TERMINAL TERMINAL $1,071.43
- 
	CED63B015 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERSFUSELESS CURRENT LIMITING; THERMAL MAGNETIC; 3 POLE; 600 VAC; 500 VDC; 15 AMPERE AT 40 DEG C; INTERRUPTING RATING 200 KILOAMPERE AT 240/480 VAC; 100 KILOAMPERE AT 600 VAC; 50 KILOAMPERE AT 500 VDC (UL); LUG LOAD TERMINAL TERMINAL $1,071.43
- 
	
- 
	
- 
	
- 
	
- 
	
- 
	
- 
	
- 
	CCL300 CUTLER-HAMMER DISTRIBUTION EQUIPMENT/CONTROLS CIRCUIT BREAKER ACCESSORIES2 CONDUCTOR(S); 300 KCMIL; QUANTITY 1; USED ON CC/CCH/CHH SERIES MAIN BREAKER $37.05
- 
	CC94.0 SQUARE D/TELEMECANIQUE THERMAL OVERLOAD HEATER ELEMENTSCLASS 20; STANDARD TRIP; MOTOR FLA 132 TO 142 AMPERE (1 THERMAL UNIT); PLUG IN MOUNTING; USED ON AC MAGNETIC STARTER; SQUARE D[R] BRAND $26.37
- 
	CC87.7 SQUARE D/TELEMECANIQUE THERMAL OVERLOAD HEATER ELEMENTSCLASS 20; STANDARD TRIP; MOTOR FLA 123 TO 131 AMPERE (1 THERMAL UNIT); PLUG IN MOUNTING; USED ON AC MAGNETIC STARTER; SQUARE D[R] BRAND $26.37
 
			         
                              
                              
                              
                             