CH120GF CUTLER-HAMMER DISTRIBUTION EQUIPMENT/CONTROLS GROUND FAULT GFCI PLUG-IN CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120 VAC; 20 AMPERE; INTERRUPTING RATING 10000 AMPERE; 5 MILLIAMPERE TRIP SENSITIVITY; WIRE SIZE 14 TO 6 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; CSA; USED ON LOADCENTER; CH MODEL
$64.91 -
CH120 CUTLER-HAMMER DISTRIBUTION EQUIPMENT/CONTROLS STANDARD TRIP PLUG-IN CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120/240 VAC; 20 AMPERE; INTERRUPTING RATING 10000 AMPERE; PLUG ON MOUNTING; APPROVAL UL 489; CSA; USED ON LOAD CENTER; CH MODEL
$7.44 -
CH115GF CUTLER-HAMMER DISTRIBUTION EQUIPMENT/CONTROLS GROUND FAULT GFCI PLUG-IN CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120 VAC; 15 AMPERE; INTERRUPTING RATING 10000 AMPERE; 5 MILLIAMPERE TRIP SENSITIVITY; WIRE SIZE 14 TO 6 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; CSA; USED ON LOADCENTER; CH MODEL
$64.91 -
CH115AF CUTLER-HAMMER CONTROLS/DISTRIBUTION EQUIPMENT ARC FAULT AFCI PLUG-IN CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120 VAC; 15 AMPERE; INTERRUPTING RATING 10000 AMPERE; SIZE 3/4 INCH W; APPROVAL UL 1699; USED ON LOAD CENTER; FIRE-GUARD[T] BRAND; CH MODEL
$77.70 -
CH115 CUTLER-HAMMER DISTRIBUTION EQUIPMENT/CONTROLS STANDARD TRIP PLUG-IN CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120/240 VAC; 15 AMPERE; INTERRUPTING RATING 10000 AMPERE; WIRE SIZE (2) 14 TO 10 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; CSA; USED ON LOAD CENTER; CH MODEL
$7.44 -
CH110 CUTLER-HAMMER DISTRIBUTION EQUIPMENT/CONTROLS STANDARD TRIP PLUG-IN CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120/240 VAC; 10 AMPERE; INTERRUPTING RATING 10000 AMPERE; WIRE SIZE (1) 14 TO 8 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; CSA; USED ON LOAD CENTER; CH MODEL
$7.70 -
CFD63B225 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
FUSELESS CURRENT LIMITING; MOLDED CASE; THERMAL MAGNETIC; FD FRAME; 600 VAC AT 50/60 HZ; 500 VDC; 225 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 200 KILOAMPERE AT 240/480 VAC; 100 KILOAMPERE AT 600 VAC; 50 KILOAMPERE AT 500 VDC (UL)
$2,191.80 -
CEL18-10 ABB CONTACTOR AUXILIARY CONTACT BLOCK
ABB CEL18-10 CONTACTOR AUXILIARY CONTACT BLOCK A95-AF1650 AUX;1NO LOW ENERGY
$15.11 -
CEL18-01 ABB CONTACTOR AUXILIARY CONTACT BLOCK
ABB CEL18-01 CONTACTOR AUXILIARY CONTACT BLOCK A95-AF1650 AUX; INC LOW ENERGY
$15.11 -
CED63B100 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
FUSELESS CURRENT LIMITING; THERMAL MAGNETIC; 3 POLE; 600 VAC; 500 VDC; 100 AMPERE AT 40 DEG C; INTERRUPTING RATING 200 KILOAMPERE AT 240/480 VAC; 100 KILOAMPERE AT 600 VAC; 50 KILOAMPERE AT 500 VDC (UL); LUG LOAD TERMINAL TERMINAL
$1,071.43 -
CED63B080 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
FUSELESS CURRENT LIMITING; THERMAL MAGNETIC; 3 POLE; 600 VAC; 500 VDC; 80 AMPERE AT 40 DEG C; INTERRUPTING RATING 200 KILOAMPERE AT 240/480 VAC; 100 KILOAMPERE AT 600 VAC; 50 KILOAMPERE AT 500 VDC (UL); LUG LOAD TERMINAL TERMINAL
$1,071.43 -
CED63B060 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
FUSELESS CURRENT LIMITING; THERMAL MAGNETIC; 3 POLE; 600 VAC; 500 VDC; 60 AMPERE AT 40 DEG C; INTERRUPTING RATING 200 KILOAMPERE AT 240/480 VAC; 100 KILOAMPERE AT 600 VAC; 50 KILOAMPERE AT 500 VDC (UL); LUG LOAD TERMINAL TERMINAL
$1,071.43 -
CED63B050 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
FUSELESS CURRENT LIMITING; THERMAL MAGNETIC; 3 POLE; 600 VAC; 500 VDC; 50 AMPERE AT 40 DEG C; INTERRUPTING RATING 200 KILOAMPERE AT 240/480 VAC; 100 KILOAMPERE AT 600 VAC; 50 KILOAMPERE AT 500 VDC (UL); LUG LOAD TERMINAL TERMINAL
$1,071.43 -
CED63B040 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
FUSELESS CURRENT LIMITING; THERMAL MAGNETIC; 3 POLE; 600 VAC; 500 VDC; 40 AMPERE AT 40 DEG C; INTERRUPTING RATING 200 KILOAMPERE AT 240/480 VAC; 100 KILOAMPERE AT 600 VAC; 50 KILOAMPERE AT 500 VDC (UL); LUG LOAD TERMINAL TERMINAL
$1,071.43 -
CED63B015 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS NON-INTERCHANGEABLE TRIP THERMAL MAGNETIC CIRCUIT BREAKERS
FUSELESS CURRENT LIMITING; THERMAL MAGNETIC; 3 POLE; 600 VAC; 500 VDC; 15 AMPERE AT 40 DEG C; INTERRUPTING RATING 200 KILOAMPERE AT 240/480 VAC; 100 KILOAMPERE AT 600 VAC; 50 KILOAMPERE AT 500 VDC (UL); LUG LOAD TERMINAL TERMINAL
$1,071.43 -
-
-
-
-
-
-
-
CCL300 CUTLER-HAMMER DISTRIBUTION EQUIPMENT/CONTROLS CIRCUIT BREAKER ACCESSORIES
2 CONDUCTOR(S); 300 KCMIL; QUANTITY 1; USED ON CC/CCH/CHH SERIES MAIN BREAKER
$37.05 -
CC94.0 SQUARE D/TELEMECANIQUE THERMAL OVERLOAD HEATER ELEMENTS
CLASS 20; STANDARD TRIP; MOTOR FLA 132 TO 142 AMPERE (1 THERMAL UNIT); PLUG IN MOUNTING; USED ON AC MAGNETIC STARTER; SQUARE D[R] BRAND
$26.37 -
CC87.7 SQUARE D/TELEMECANIQUE THERMAL OVERLOAD HEATER ELEMENTS
CLASS 20; STANDARD TRIP; MOTOR FLA 123 TO 131 AMPERE (1 THERMAL UNIT); PLUG IN MOUNTING; USED ON AC MAGNETIC STARTER; SQUARE D[R] BRAND
$26.37