1 × $242.66
-
1 × $239.29
-
1 × $112.60
-
1 × $143.70
-
1 × $50.25
-
1 × $180.79
-
1 × $243.71
-
1 × $219.80
-
1 × $236.68
-
1 × $940.64
-
1 × $1,016.50
-
1 × $3,357.83
-
1 × $3,378.24
-
1 × $69.61
-
1 × $43.62
-
1 × $2,328.35
-
1 × $186.54
-
1 × $205.16
-
1 × $243.71
-
1 × $97.67
-
1 × $391.20
-
1 × $232.73
-
1 × $365.95
-
1 × $40.79
-
1 × $100.35
-
EDB34125 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 3 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 125 AMPERE; INTERRUPTING RATING 25 KILOAMPERE AT 120/240 VAC; 18 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$2,835.48 -
EDB34100 SQUARE D BREAKER 480 VOLT 100 AMP
THERMAL MAGNETIC; BRANCH; 3 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 100 AMPERE; INTERRUPTING RATING 25 KILOAMPERE AT 120/240 VAC; 18 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$1,066.96 -
EDB34090 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 3 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 90 AMPERE; INTERRUPTING RATING 25 KILOAMPERE AT 120/240 VAC; 18 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$1,066.96 -
EDB34080 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 3 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 80 AMPERE; INTERRUPTING RATING 25 KILOAMPERE AT 120/240 VAC; 18 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$1,066.96 -
EDB34070 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 3 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 70 AMPERE; INTERRUPTING RATING 25 KILOAMPERE AT 120/240 VAC; 18 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$1,068.60 -
EDB34060 SQUARE D
THERMAL MAGNETIC; BRANCH; 3 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 60 AMPERE; INTERRUPTING RATING 25 KILOAMPERE AT 120/240 VAC; 18 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$783.53EDB34060 SQUARE D
$783.53 -
EDB34050 SQUARE D CIRCUIT BREAKER
THERMAL MAGNETIC; BRANCH; 3 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 50 AMPERE; INTERRUPTING RATING 25 KILOAMPERE AT 120/240 VAC; 18 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$783.53 -
EDB34045 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 3 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 45 AMPERE; INTERRUPTING RATING 25 KILOAMPERE AT 120/240 VAC; 18 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$783.53 -
EDB34040 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 3 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 40 AMPERE; INTERRUPTING RATING 25 KILOAMPERE AT 120/240 VAC; 18 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$783.53 -
EDB34035 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 3 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 35 AMPERE; INTERRUPTING RATING 25 KILOAMPERE AT 120/240 VAC; 18 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$783.53 -
EDB34030 SQUARE D BOLT ON BREAKER
THERMAL MAGNETIC; BRANCH; 3 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 30 AMPERE; INTERRUPTING RATING 25 KILOAMPERE AT 120/240 VAC; 18 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$783.53 -
EDB34025 SQUARE D BREAKER
THERMAL MAGNETIC; BRANCH; 3 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 25 AMPERE; INTERRUPTING RATING 25 KILOAMPERE AT 120/240 VAC; 18 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$783.53EDB34025 SQUARE D BREAKER
$783.53 -
EDB34020 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 3 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 20 AMPERE; INTERRUPTING RATING 25 KILOAMPERE AT 120/240 VAC; 18 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$783.53 -
EDB34015 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 3 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 15 AMPERE; INTERRUPTING RATING 25 KILOAMPERE AT 120/240 VAC; 18 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$783.53 -
EDB24125 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 2 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 125 AMPERE; INTERRUPTING RATING 25 KILOAMPERE AT 120/240 VAC; 18 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$2,279.16 -
EDB24100 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 2 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 100 AMPERE; INTERRUPTING RATING 25 KILOAMPERE AT 120/240 VAC; 18 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$885.43 -
EDB24090 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 2 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 90 AMPERE; INTERRUPTING RATING 25 KILOAMPERE AT 120/240 VAC; 18 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$1,328.14 -
EDB24080 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 2 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 80 AMPERE; INTERRUPTING RATING 25 KILOAMPERE AT 120/240 VAC; 18 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$885.43 -
EDB24070 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 2 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 70 AMPERE; INTERRUPTING RATING 25 KILOAMPERE AT 120/240 VAC; 18 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$885.43 -
EDB24060 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 2 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 60 AMPERE; INTERRUPTING RATING 25 KILOAMPERE AT 120/240 VAC; 18 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$627.76 -
EDB24050 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 2 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 50 AMPERE; INTERRUPTING RATING 25 KILOAMPERE AT 120/240 VAC; 18 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$627.76 -
EDB24045 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 2 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 45 AMPERE; INTERRUPTING RATING 25 KILOAMPERE AT 120/240 VAC; 18 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$627.76 -
EDB24040 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 2 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 40 AMPERE; INTERRUPTING RATING 25 KILOAMPERE AT 120/240 VAC; 18 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$628.73 -
EDB24035 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 2 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 35 AMPERE; INTERRUPTING RATING 25 KILOAMPERE AT 120/240 VAC; 18 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$627.76 -
EDB24030 SQUARE D/TELEMECANIQUE STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
THERMAL MAGNETIC; BRANCH; 2 POLE; 120/240/277 VAC AT 50/60 HZ; 480 VAC STAR/277 VAC AT 50/60 HZ (UL/CSA); 30 AMPERE; INTERRUPTING RATING 25 KILOAMPERE AT 120/240 VAC; 18 KILOAMPERE AT 277 VAC OR 480 VAC STAR/277 VAC (UL/CSA)
$627.76