1 × $7.19
-
1 × $0.69
-
1 × $81.72
-
1 × $139.94
-
1 × $7.19
-
1 × $20.54
-
1 × $699.55
-
1 × $2,363.36
-
1 × $101.84
-
1 × $167.80
-
1 × $616.18
-
1 × $92.08
-
1 × $21.10
-
1 × $23.98
-
1 × $39.27
-
1 × $6.89
-
1 × $259.60
-
1 × $347.58
-
1 × $1,107.39
-
1 × $93.02
-
1 × $1,612.21
-
1 × $6.23
-
1 × $262.79
-
1 × $18.65
-
1 × $7.15
-
1 × $1,781.62
-
1 × $100.38
-
1 × $4,381.98
-
1 × $602.81
-
1 × $4.54
-
1 × $108.36
-
1 × $294.78
-
1 × $3.37
-
1 × $16.04
-
1 × $258.41
-
1 × $938.20
-
1 × $149.72
-
1 × $1,612.21
-
1 × $984.12
-
1 × $1.78
-
1 × $0.74
-
1 × $1,288.23
-
1 × $59.75
-
1 × $82.70
-
2 × $7.19
-
1 × $1,612.21
-
1 × $255.64
-
1 × $100.10
-
1 × $172.51
-
1 × $100.10
-
1 × $199.47
-
1 × $170.44
-
1 × $1,615.38
-
1 × $101.67
-
1 × $3.28
-
1 × $6.38
-
1 × $366.78
-
1 × $2,772.63
-
1 × $215.30
-
1 × $0.00
-
1 × $783.53
-
1 × $832.83
-
1 × $1,771.16
-
1 × $9,087.36
-
1 × $82.70
-
1 × $306.31
-
1 × $1,560.09
-
1 × $11.10
-
1 × $179.06
-
1 × $269.55
-
1 × $18.52
-
1 × $13.31
-
1 × $62.60
-
1 × $1,196.17
-
1 × $7.57
-
1 × $100.21
-
1 × $196.06
-
1 × $3,197.38
-
1 × $39,756.38
-
1 × $19.53
-
1 × $100.21
-
1 × $78.08
-
1 × $3.47
-
1 × $7.19
-
BR115 CUTLER-HAMMER CIRCUIT PROTECT DEV STANDARD TRIP PLUG-IN CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120/240 VAC; 15 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL
$10.72 -
BR110 CUTLER-HAMMER CIRCUIT PROTECT DEV STANDARD TRIP PLUG-IN CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120/240 VAC; 10 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL
$7.35 -
BQDPLD SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS CIRCUIT BREAKER ACCESSORIES
PADLOCKABLE; 1/2/3 POLE; OFF LOCKING PROVISION; USED ON BQD/CQD FRAME CIRCUIT BREAKER; SPEEDFAX[T] BRAND
$19.48 -
BQDHBD SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS CIRCUIT BREAKER ACCESSORIES
ON/OFF LOCKING PROVISION; USED ON BQD; CQD FRAME CIRCUIT BREAKER
$9.74 -
BQD390 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ (UL); 90 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC (UL); TERMINAL LOAD LUG; SIZE 3 INCH W X 4.49 INCH H
$305.20 -
BQD370 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ (UL); 70 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC (UL); TERMINAL LOAD LUG; SIZE 3 INCH W X 4.49 INCH H
$305.20 -
BQD360 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ (UL); 60 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC (UL); TERMINAL LOAD LUG; SIZE 3 INCH W X 4.49 INCH H
$232.36 -
BQD350 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ (UL); 50 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC (UL); TERMINAL LOAD LUG; SIZE 3 INCH W X 4.49 INCH H
$232.36 -
BQD340 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ (UL); 40 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC (UL); TERMINAL LOAD LUG; SIZE 3 INCH W X 4.49 INCH H
$232.36 -
BQD335 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ (UL); 35 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC (UL); TERMINAL LOAD LUG; SIZE 3 INCH W X 4.49 INCH H
$232.36 -
BQD330 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ (UL); 30 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC (UL); TERMINAL LOAD LUG; SIZE 3 INCH W X 4.49 INCH H
$232.36 -
BQD325 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ (UL); 25 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC (UL); TERMINAL LOAD LUG; SIZE 3 INCH W X 4.49 INCH H
$232.36 -
BQD320 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ (UL); 20 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC (UL); TERMINAL LOAD LUG; SIZE 3 INCH W X 4.49 INCH H
$232.36 -
BQD315 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ (UL); 15 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC (UL); TERMINAL LOAD LUG; SIZE 3 INCH W X 4.49 INCH H
$232.36 -
BQD3100 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ (UL); 100 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC (UL); TERMINAL LOAD LUG; SIZE 3 INCH W X 4.49 INCH H
$305.20 -
BQD290 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 90 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$271.24 -
BQD280 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 80 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$271.24 -
BQD270 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 70 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$271.24 -
BQD260 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 60 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$138.15 -
BQD250 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 50 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$138.15 -
BQD245 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 45 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$138.15 -
BQD240 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 40 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$138.15 -
BQD235 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 35 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$138.15 -
BQD230 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 30 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$138.15 -
BQD225 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 25 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$138.15