-
1 × $0.89
-
1 × $174.94
-
1 × $138.65
-
1 × $3.41
-
1 × $3.95
-
1 × $1.66
-
1 × $4.17
-
1 × $188.74
-
1 × $3.57
-
1 × $226.04
-
1 × $3,114.23
-
1 × $470.83
-
1 × $0.89
-
1 × $1,503.54
-
1 × $148.09
-
1 × $5.46
-
1 × $7.19
-
1 × $34.15
-
1 × $6,178.45
-
1 × $82.04
-
1 × $15.47
-
1 × $180.29
-
1 × $6.89
-
1 × $1.79
-
1 × $4,279.33
-
1 × $1,553.62
-
1 × $1,630.47
-
1 × $97.67
-
1 × $1.78
-
1 × $7.19
-
1 × $191.80
-
1 × $93.79
-
1 × $610.25
-
1 × $620.18
-
1 × $64.91
-
1 × $323.15
-
1 × $7.19
-
1 × $1.32
-
1 × $397.16
-
1 × $200.22
-
1 × $189.93
-
1 × $250.87
-
1 × $6,281.89
-
1 × $1.16
-
1 × $357.48
-
1 × $86.33
-
1 × $6,414.23
-
1 × $250.09
-
1 × $106.81
-
1 × $1,856.79
-
1 × $19.06
-
1 × $4.05
-
1 × $99.70
-
1 × $8.74
-
1 × $206.04
-
1 × $7.19
-
1 × $62.17
-
1 × $7.19
-
1 × $374.99
-
BR115 CUTLER-HAMMER CIRCUIT PROTECT DEV STANDARD TRIP PLUG-IN CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120/240 VAC; 15 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL
$10.72 -
BR110 CUTLER-HAMMER CIRCUIT PROTECT DEV STANDARD TRIP PLUG-IN CIRCUIT BREAKERS
THERMAL MAGNETIC; 1 POLE; 120/240 VAC; 10 AMPERE; INTERRUPTING RATING 10 KILOAMPERE; WIRE SIZE 14 TO 4 AWG (ALUMINUM/COPPER); PLUG ON MOUNTING; APPROVAL UL 489; USED ON LOAD CENTER; BR MODEL
$7.35 -
BQDPLD SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS CIRCUIT BREAKER ACCESSORIES
PADLOCKABLE; 1/2/3 POLE; OFF LOCKING PROVISION; USED ON BQD/CQD FRAME CIRCUIT BREAKER; SPEEDFAX[T] BRAND
$19.48 -
BQDHBD SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS CIRCUIT BREAKER ACCESSORIES
ON/OFF LOCKING PROVISION; USED ON BQD; CQD FRAME CIRCUIT BREAKER
$9.74 -
BQD390 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ (UL); 90 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC (UL); TERMINAL LOAD LUG; SIZE 3 INCH W X 4.49 INCH H
$305.20 -
BQD370 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ (UL); 70 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC (UL); TERMINAL LOAD LUG; SIZE 3 INCH W X 4.49 INCH H
$305.20 -
BQD360 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ (UL); 60 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC (UL); TERMINAL LOAD LUG; SIZE 3 INCH W X 4.49 INCH H
$232.36 -
BQD350 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ (UL); 50 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC (UL); TERMINAL LOAD LUG; SIZE 3 INCH W X 4.49 INCH H
$232.36 -
BQD340 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ (UL); 40 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC (UL); TERMINAL LOAD LUG; SIZE 3 INCH W X 4.49 INCH H
$232.36 -
BQD335 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ (UL); 35 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC (UL); TERMINAL LOAD LUG; SIZE 3 INCH W X 4.49 INCH H
$232.36 -
BQD330 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ (UL); 30 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC (UL); TERMINAL LOAD LUG; SIZE 3 INCH W X 4.49 INCH H
$232.36 -
BQD325 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ (UL); 25 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC (UL); TERMINAL LOAD LUG; SIZE 3 INCH W X 4.49 INCH H
$232.36 -
BQD320 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ (UL); 20 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC (UL); TERMINAL LOAD LUG; SIZE 3 INCH W X 4.49 INCH H
$232.36 -
BQD315 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ (UL); 15 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC (UL); TERMINAL LOAD LUG; SIZE 3 INCH W X 4.49 INCH H
$232.36 -
BQD3100 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ (UL); 100 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC (UL); TERMINAL LOAD LUG; SIZE 3 INCH W X 4.49 INCH H
$305.20 -
BQD290 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 90 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$271.24 -
BQD280 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 80 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$271.24 -
BQD270 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 70 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$271.24 -
BQD260 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 60 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$138.15 -
BQD250 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 50 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$138.15 -
BQD245 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 45 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$138.15 -
BQD240 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 40 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$138.15 -
BQD235 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 35 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$138.15 -
BQD230 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 30 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$138.15 -
BQD225 SIEMENS ELECTRICAL DISTRIBUTION PRODUCTS STANDARD TRIP BOLT-ON CIRCUIT BREAKERS
MOLDED CASE; THERMAL MAGNETIC; BQD FRAME; 240 VAC/480 VAC STAR/277 VAC AT 60 HZ; 125/250 VDC (UL); 25 AMPERE AT 40 DEG C; 2 POLE; INTERRUPTING RATING 65 KILOAMPERE AT 240 VAC; 14 KILOAMPERE AT 480 VAC STAR/277 VAC/250 VDC (UL); TERMINAL LOAD LUG
$138.15